Description
Conducted Immunity Generator Features
- 6.6kV Surge & 100kHz Ring Wave, EFT 4.8kV
- ISO 17025 Accredited Calibration included
- CDNs - Single/Three phase up to 620V/100A
- Free Technical Support & 2 Days Free Transit
- Touch Panel Screen, Easy to use Architecture
- Both IEC and ANSI coupling methods
- Turnkey Solution - Arrives Ready for Testing!
Overview
The Teseq (previously Schaffner) NSG 3060 EMC Immunity generator provides testing for EFT(electrical fast transients) to 4.8kV, Surge to 6.6kV, 100kHz ring wave to 6.6kV and offers solutions for both CE mark, ANSI, and IEC testing. A2LA accredited calibration and two free days of transit time is included in the rental equipment price. It includes both coupling methods associated with IEC and ANSI EMC testing standards. We also offer the full line of accessories available for rent, including the CDN 3083 series (CDN3083-S100 & CDN3083-B100), allowing for enhanced testing capabilities.
This multifunction generator offers a user-friendly design to help streamline testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN 61000-4-12, ANSI C62.41, C62.45, and UL 1449. It offers a 7" color screen and easy to manage user-interface allowing for easy adjustments with the thumb-wheel. This system is often rented with the CDN 3061 (coupling decoupling network) allowing for single phase coupling up to 270V/16A.
This Immunity Test Generator has a Ethernet port for connect with a PC and includes window based software. This simplifies electromagnetic compatibility testing allowing for compilation of complex test sequences with diverse pulse types. The software with the NSG3060 test set enables the user to create reports and enter observations as the test progresses increasing the efficiency of long-term tests.
Data SheetUser Manual Application Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN 61000-4-12 ANSI C62.41, C62.45, UL 1449 |
|
|
Standards |
IEC 61000-4-4, ed.3 |
Voltage Waveform into 50Ω load |
5ns rise time±30%, 50ns pulse width ±30%, |
Voltage Waveform into 1000Ω load |
5ns rise time±30%, 50ns pulse width ±30%, |
Voltage Amplitude |
±100V to 2.4kV into 50Ω, ± 200V to 4.8kV into 1000Ω |
Burst Duration |
1 µs to 1999 s |
Burst Period |
1 ms to 4200 s |
Frequency |
100 Hz to 1000 kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ±30%, 50µs Duration ±20% |
Short Circuit Current Waveform |
8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–6.6kV |
Peak Short Circuit Current |
100A–3.3kA @2 Ω, 16.6-550A@12Ω |
100kHz Ringwave: |
|
Standards |
IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B, ANSI C62.45 |
Open Circuit Voltage Waveform |
100kHz Damped Cosine, risetime=.5µs+/-30%, Damping= 40%/peak |
Peak Open Circuit Voltage |
200V–6.6kV @12 Ω or @ 30 Ω |
Peak Short Circuit Current |
±6.6 to ±220 A ±10%@30 Ω ±16.6 to ±550 A ±10%@12 Ω |
Impulse Repetition Rate |
10s from 200V to 4400V, 20s from 4401V to 6600V |
Dips and Interrupts: |
INA 6502 external variac is available as a separate option |
Packing List/Accessories
Included with Rental Of Teseq NSG 3060
Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. This does not include any coupler/decoupler items or accessories. A detailed list of these can be found on the "All Accessories" tab.
NSG 3060
- Conducted Immunity System
- Control Software USB with License
- Calibration Documentation
- Power Cord
- Laptop with Charger
- Cross Over/ Ethernet Cable
- Printed Manual
- Interlock/Keeper
- Black Plastic Screw
- WIN3000 Installation Guide
- Shipping Case
- Weight: 140 LBS
- Dimensions: 28x26x18
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3060 Full Accessory List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 3063-C32 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A |
CDN 3063-C63 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verification set |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 3005-S16 |
Automatic variable transformer, 1 x 16 A |
VAR 3005-D16 |
Automatic variable transformer, 2 x 16 A |
MFO 6501 |
Manual magnetic field option -4-8 |
MFO 6502 |
Automatic magnetic field option -4-8 |
INA 701 |
Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9 |
INA 702 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator |
INA 752 |
Pulse shape adapter |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this immunity generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.
- EMC Directives
- UN ECE R10 (Automotive)
- IEC/EN 61000-4-4
- IEC/EN 61000-4-5
- IEC/EN 61000-4-8
- IEC/EN 61000-4-9
- IEC/EN 61000-4-11
- IEC/EN 61000-4-12
- IEC/EN 61000-4-29
- ANSI/IEEE C62.41
- EN 61000-6-1
- EN 61000-6-2
- EN 50370
- EN 61643
- EN 300386-2
- EN 300386 V1.3.2
- EN 301489-1
- EN 301489-7
- EN 301489-17
- EN 301489-24
- FCC 97-270 (part 68)
- IEC 60255-1
- IEC 60601-1-2
- IEC 61009-1
- IEC 61326
- IEC 61850-3
- ITU-T K.12
- ITU-T K.20
- ITU-T K.21
- ITU-T K.28
- ITU-T K.41
- ITU-T K.44
- ITU-T K.45
Videos
NSG 3060 - Overview & Setup: Transient Specialists
Description: This video provides an overview of the NSG 3060 immunity test generator for surge, ringwave, and electrical fast transient (EFT) testing with the CDN 3061 single phase coupler decoupler 270v/16amps. It talks briefly about capabilities of the test system, setup, and additional considerations. All of these pieces of test equipment are available for rental and come with ISO 17025 calibrations.
NSG 3060 -Multifunction Genertor Teseq
Description: This video made by Teseq, now owned by Ametek, provides overview of this test system including the capabilities and changing testing parameter. Video also includes both CDN 3083 & CDN 3061 coupling decoupling networks.