Teseq CIP 9136A - Rent 400 MHz Current Injection Probe

Teseq Current Injection Probe:

  • 10 kHz to 400 MHz Probe 1kW Maximum
  • Compliant IEC 61000-4-6, ISO 11452-4, & CS114
  • Calibraiton Fixture (PCJ 9201) Included
  • Used for Transient Testing to ISO 7637-3
  • Ideal for BCI with NSG 4070/CWS 500N

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Conducted RF Accessories

Description

Overview

The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ. It meets the requirements for HIRF testing where conventional ferrite core material cannot handle the higher powers required (up to 1000 W), without changing characteristics when heated. Whilst having been initially designed to meet the specific requirements of Aircraft Testing from 10 kHz to 50 MHz, the CIP 9136’s unique non-ferrite core allows wide band performance from 4 kHz - 400 MHz, and above.

CIP 9136A - Data Sheet CIP 9136A - User Manual

Specifications

Common Standards

 ISO 11452-2, IEC 61000-4-6, MIL-STD-461 CS114, DO 160 sec 20

Input Power Rating

1kW

Frequency

4kHz – 400MHz

Window Diameter

43mm

Outside Diameter

113mm

Width

61mm

Weight

2kg

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this immunity generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

 

  • IEC/EN 61000-4-6
  • CISPR 24
  • EN 61000-6-1
  • EN 61000-6-2
  • IEC 60601-1-2
  • IEC 61326
  • MIL STD 461
  • RTCA/DO 160
  • ISO 11452-4
  • SAE J1113-4