- Frequency range:
- 4 kHz to 1 GHz
- Resolution:
- 1 Hz
- Reference frequency:
- 10 MHz
- Aging:
- 25 ppm
- Level range:
- 60 dBm to +10 dBm
- Resolution:
- 0.1 dB
- Settling time:
- 10 ms
- Modulation depth:
- 0 to 100%
- Modulation frequency range:
- 1 Hz to 50 kHz
- Frequency resolution:
- 1 Hz
- Rise/fall time (10%/90%):
- < 1 us
- Modulation frequency range:
- 0.01 Hz to 1 MHz
- Frequency resolution:
- 0.01 Hz
- Duty cycle:
- 0.1% to 100%
- Delay time:
- < 1 us /180 Degrees
- Period:
- min. 20 us
- Pulse width:
- min. 10 us
- Frequency range:
- 4 kHz to 1 GHz
- Linear measurement range
- -35 dBm to +27 dBm (NSG 4070C-60 and NSG 4070C-110:-40 dBm to +27 dBm)
- channel 2,3:
- 45 dBm to +20 dBm
- Max. input/no damage channel 1-3:
- +28 dBm
- Noise level:
- >5 dB below the measurement range
- Input return loss:
- >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
- Connector:
- BNC socket, 50 Ohm
- Accuracy 10 to 30�C:
- <0.5 dB, typ. <0.3 dB
- Nominal output power:
- 110 W
- Frequency range:
- 10 kHz (4 kHz) to 230 MHz
- Type:
- single band, class A
- Input/output impedance (nominal):
- 50 Ohms
- Input return loss (minimum):
- 10 dB
- Output return loss without damage:
- 0 dB
- Gain (minimum):
- 4 kHz to 10 kHz 47 dB
10 kHz to 400 MHz 55 dB
- Gain flatness (maximum):
- +/- 3 dB
- Saturated output power (minimum):
- 4 kHz to 10 kHz 43 dBm
10 kHz to 400 MHz 50.4 dBm
- Linear output power (minimum):
- 4 kHz to 10 kHz 41 dBm
10 kHz to 400 MHz 49 dBm
- Input power without damage (maximum):
- +10 dBm
- Harmonic distortion at linear output power (typical):
- < -20 dBc
- Generator output:
- N socket 50 Ohms, 4 kHz to 1 GHz
- Power amplifier input:
- N socket 50 Ohms, max. +10 dBm
- Power amplifier output:
- N socket 50 Ohms
- Power meter channel 1 to 3:
- as defined in chapter Power meter
- Monitoring input analog:
- BNC socket, 0 to 24 V Ri=15 kOhms, 6 mV resolution
- External modulation input:
- BNC socket, impedance >10 kOhms, level: 1 Vpp to get 100% AM, 1 Hz to 50 kHz
- 10 MHz reference output:
- BNC socket, approx. 1 Vpp/50 Ohms
- Operating temperature range:
- 0 C to 40 C
- Storage temperature range:
- : -20 C to 60 C
- Relative humidity:
- 95 %/30 C (no moisture condensation)
- EMC:
- DIN/EN 61326-1:2006
- Shock:
- DIN/EN 60068-2-27
- Vibration:
- DIN/EN 60068-2-6
- Protection class:
- DIN/EN 61010-1/IEC 61010-1
- Size (W x H x D):
- 45 cm (19 Inches) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
- Weight:
- approx. 15 kg (with internal power amplifier),
approx. 8 kg (without internal power amplifier)
- Size of cardboard box:
- 80 cm x 61 cm x 34 cm (also for options ATN 60xx and/or LE 4070 additional space available)
- Weight of cardboard box:
- approx. 8 kg (empty)