EMC Partner IMU-MGS
Included Accessories
Can't find something? Contact UsRelated Equipment
Description
Modular test system with colour touch screen and intuitive software. An integrated help with graphics guide the user through fast and efficient setup and operation. The system is used for CE mark testing in the European Union. Each system can be individually configured and easily extended. 10 modules are available for the IMU-MGS. All modules are easily added or removed by the user on-site.
The generator can be configured for IEC / EN and also ANSI test requirements. ElectroMagnetic Compatibility (EMC) tests for Surge up to 5kV and EFT up to 5kV are freely configurable by the user. IMU-MGS is programmed with default parameters from the IEC basic standards. A test library including basic and generic requirements is also included in the IMU-MGS.
- IMU-MGS Mainframe
- EUT power input 1 (CDN)
- max. AC/DC 300V, 16A (fused 16A) with P module
- EUT power input 2 (CDN)
- max. AC/DC 300V, 16A (not fused) with P module
- Internal CDN freq. range
- DC, 50 Hz, 60 Hz
- Power freq. synchr.
- 50/60 Hz
- Coupling Burst
- L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct out
- Coupling Surge
- 2 ?: L-N, direct out, 12 ?: L-PE, N-PE
- IMU-MGS Control Features
- Operating system
- EPOS propietary firmware
- Languages
- 8 menu languages, selectable
- User interface
- 7 inch capacitive touch display
- Connectivity
- gigabit ethernet, USB, RS485
- Environment meas.
- built-in temperature and humidity sensor
- EUT power monitor
- supply voltage, current and freq. on screen
- EUT supply voltage waveform
- monitoring BNC output connector max. 15 V
- EUT supply current waveform
- monitoring BNC output connector max. 15 V
- Surge monitoring
- peak voltage and current on screen, waveform available at BNC outputs
- Surge voltage waveform
- monitoring BNC output connector max. 15 V
- Surge current waveform
- monitoring BNC output connector max. 15 V
- Trigger out
- BNC connector, max. 6 V
- Trigger in
- auto, manual or via programmable BNC
- Programmable connectors
- 2 BNC connectors (inputs/outputs) as follows
- Programmable input functions
- Trigger Input, Start Test, Stop Test, EUT Fail, EUT Mark, Emergency Stop
- Programmable input max. voltage
- low range: 0 - 1.5 V, high range: 2.3 - 24 V
- Programmable output functions
- Running State, Safety Circuit State
- Programmable output max. U, I
- max. 24 V, max. 300 mA
- Synchronization source
- EUT power, direct out, external
- Synchronization angle
- 0 - 359 degree +/- 5 degrees, 1 degree step
- Input EUT power selection
- PWR1 and PWR2 selectable on the screen
- Power ON/OFF process
- sophisticated functions allow to switch EUT power ON/OFF at selectable voltage angle (0 - 359 degrees, 1 degree step)
- Impulse polarity
- positive, negative, alternating
- Automatic ramps
- test level, sync. angle, coupling path
- EUT overcurrent protection
- automatic programmable fuse up to 16 A
- PS3 control
- DC, 16.7 Hz, 50 Hz, 60 Hz supply power
- Safety features (standard)
- Emergency stop button on front panel red/yellow as per IEC 60947-5-5, IEC 60204-1, ISO 13850, Safety circuit
- IMU-MGS module: EXT-IMU4000 F4
- Standard
- IEC 61000-4-4 latest edition
- Output impedance
- 50 Ohm
- Voltage OC
- 0.2 kV - 4.4 kV
- Voltage into 50 ?
- 0.1 kV - 2.2 kV +/- 10 %
- Waveform into 50 ?
- 5 +/- 1.5 ns / 50 +/- 15 ns
- Voltage into 1 k?
- 0.191 kV - 4.18 kV +/- 20%
- Waveform into 1 k?
- 5 +/- 1.5 ns / 50 ns (-15/+100 ns)
- Spike frequency
- 1 kHz - 1 MHz
- Maximum spikes / second
- 8000 @ 1 kV
- Burst duration
- 0.01 ms - 30 ms, continuous up to 8 kHz
- Burst repetition
- 1 - 1000 ms
- Polarity
- positive, negative, alternating
- Synchronization
- 0 - 359 degrees, step 1 degree
- Ramps
- voltage, spike frequency, burst duration
- IMU-MGS module: EXT-IMU4000 S4
- Standard
- IEC 61000-4-5 latest edition
- Output impedance
- 2 ?
- Voltage OC
- 0.25 kV - 4.1 kV +/- 10 %
- Voltage waveform
- 1.2 us +/- 30 % / 50 us +/- 20 %
- Current SC
- 0.125 kA - 2.05 kA +/- 10 %
- Current waveform
- 8 us +/- 20 % / 20 us +/- 20 %
- Pulse repetition
- up to 1 / s @ 0.8 kV, 1 / 5 s @ 4.1 kV
- Polarity
- positive, negative, alternating
- Synchronization
- 0 - 359 degrees, step 1 degree
- Ramps
- voltage, synchronisation angle
- Magnetic pulse test
- IEC 61000-4-9, see MF1000-x coils
- IMU-MGS mainframe:
- Operating voltage
- 100 - 240 V (50/60 Hz) +/- 10 %
- Power consumption
- ON < 150 VA, standby < 15 VA
- Weight
- 16 kg (weight of modules not included)
- W x d x h
- 520 x 433 x 180 mm
- Version
- 19 inch unit, 4 UH