CNI 508N2 CDN - Communication Line Surge Coupler 1GBIT/S

Signal/Data Line CDN

CNI 508N2 CDN - Communication Line Surge Coupler 1GBIT/S

CDN Telecom/Communication 1Gbit/s Features

      • Coupling unshielded and shielded lines with up to 4 pairs
      • ISO 17025 Calibration & 2 Days Free Transit
      • Surge test to 3kV (1.2/50us) & Burst Test to 4kV (5/50ns)
      • Residual voltage max. 50V at 3kV Surge 
      • Compatible to PoE and PoE+ requirements
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The CNI 508N2 from AMETEK CTS is the first coupling/decoupling network available on the market to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000MBit/s. Additionally, the CNI 508N2 can be used as a coupling/decoupling network to apply Burst- as well as Surge pulses to unshielded symmetrical interconnection lines. The CNI 508 N2 meets the requirements according Figure 11 and Figure 12 to the standards IEC 61000-4-5 (Ed. 3.0 :2014).

Data/Telecom CDN Equipment

CDN Telecom/Communication 1Gbit/s Features

      • Coupling unshielded and shielded lines with up to 4 pairs
      • ISO 17025 Calibration & 2 Days Free Transit
      • Surge test to 3kV (1.2/50us) & Burst Test to 4kV (5/50ns)
      • Residual voltage max. 50V at 3kV Surge 
      • Compatible to PoE and PoE+ requirements
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The CNI 508N2 from AMETEK CTS is the first coupling/decoupling network available on the market to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000MBit/s. Additionally, the CNI 508N2 can be used as a coupling/decoupling network to apply Burst- as well as Surge pulses to unshielded symmetrical interconnection lines. The CNI 508 N2 meets the requirements according Figure 11 and Figure 12 to the standards IEC 61000-4-5 (Ed. 3.0 :2014). Data Sheet

Common Standards

EN/IEC 61000-4-4 & EN/IEC 61000-4-5

Surge Test Mode

 

Coupling mode

shielded and unshielded cable with up to 4 pairs

Test voltage

Max. 3kV* (1.2/50us) (* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5kV)


Residual voltage Max. 50V @3kV Surge, line - PE
Bust Test Mode

Coupling mode

shielded cable with up to 4 pairs

Test voltage

Max. 4kV* (5/50ns) (* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5kV)

Residual voltage line - PE

Max. 40V @2kV Burst, Max. 60V @4kV Burst

Telecom Line Specifications

Input/Output

RJ45 female connectors for telecom lines

Terminal layout

Pair 1: pins 1/2

Pair 2: pins 3/6

Pair 3: pins 4/5

Pair 4: pins 7/8 

Data rate

up to 1,000MBit/s

Protection +- 60V between two pairs

Operating voltage

max. 57VDC

Operating current

max. 1A

Inputs

Surge shield

SHV connector

Surge unshielded 

SHV connector

Burst

SHV connector

General Data

Dimensions

270mm x 110mm x 140mm (LxWxH)

Weight