EM Test PCD 8 B-3-690-1000-100 Front Side
EM Test PCD 8 B-3-690-1000-100 Side
EM Test PCD 8 B-3-690-1000-100 Video Overview
EM Test PCD 8 B-3-690-1000-100 Top
EM Test PCD 8 B-3-690-1000-100 Side Terminals

EM Test PCD 8 B-3-690-1000-100

Rent 100 Amp EFT/Burst CDN

In Stock & Ready To Ship
Orders by 3pm ship today

Designed for high-current transient immunity testing, the EM Test PCD 8 B-3-690-1000-100 manually couples EFT/burst pulses up to 8 kV onto 100-amp, three-phase 690 VAC or 1,000 VDC power lines.

Features

  • Coupler for EFT/Burst to IEC 61000-4-4
  • Max 100 Amps 690 V AC or 1,000 V DC
  • Manual Coupler for NX5/NX7 Systems
  • Allows for Burst Voltages up to 8 kV
  • Current ISO 17025 Accredited Calibration
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period

Description

Burst pulses are applied to high voltage and high current supply lines by means of standalone coupling/decoupling networks. For such testing AMETEK CTS offers the PCD 8 b-3-690-1000-100 for supply lines up to 3 * 690 V AC, 1.000 V DC and max. 100 A. According to IEC/EN 61000-4-4 the pulses are coupled via 33 nF capacitors to all lines simultaneously (common mode).

Specifications:
Model: PCD 8 B-3-690-1000-100
8 kV coupling/decoupling network max. line current 100 A (AC and DC)
AC voltage EUT
3 * 690 V (p-p)
DC voltage EUT
1.000 V
AC/DC current EUT
100 A
Burst coupling
Common mode to all supply lines
Technical Data
Impulse voltage
max 8.0 kV +/-10 %
Coupling
Common mode
Coupling capacitance
33 nF to all lines
Coupling common mode
to L1, L2, L3, N, PE
Residual voltage
< 400 V @ 4000 V burst
EUT data:
Lines
AC: L1, L2, L3, N, PE
DC: Use L1 and N for DC-supply
Supply voltage
max. 3 * 690 V AC (p-p)
max. 1.000 V DC
EUT current
max. 100 A
Output socket
Screw terminal rated for 200 A, 6 mm (max. 8 Nm)
General:
EFT/Burst connector
SHV
Dimensions (LxWxH)
410 mm x 170 mm x 190 mm
Weight
5 Kg
Environment:
Temperature
10 C to 40 C
Humidity
30 % to 78 %, non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar
EM Test PCD 8 B-3-690-1000-100 User Manual
Download
EM Test PCD 8 B-3-690-1000-100 Datasheet
Download

Video Library

Video Guides
Related Videos

Rent the EM Test PCD 8 B-3-690-1000-100

Weekly, two-week and monthly rentals available.

Questions?630-887-0329