Rent 7 kV Compact Transient Generator

In Stock & Ready To Ship
Orders by 3pm ship today

The EM Test NX7 is a multifunction immunity test system with a built-in CDN supporting surge, EFT/burst, ring wave, and power quality testing IEC and ANSI requirements.

Features

  • 7 kV Surge, 5.5 kV EFT, & 7 kV 100 kHz Ringwave
  • Built-in single phase CDN Max 300 V/16 A AC or DC
  • Laptop with iec.control software included
  • Available Three-phase CDNs up to 125 Amps
  • Current ISO 17025 Accredited Calibration
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period
  • Conducted Immunity Test System
  • Laptop
  • Power Cord
  • Printed Manual 
  • Calibration Documentation
  • ESC EUT Power In Cord
  • ESA 1.6 EUT Supply Adapter
  • SCC AD Short Circuit Interlock
  • SWLAD Warning Lamp Adapter Interlock
  • Ethernet Cable
  • Software on USB Stick
  • Software License
  • UOC Optical Converter USB to LWL
  • 5m. Orange Fiber-optic cable
  • EFT Ground Strip
  • Case
  • EM Test NX7 bspr-1-300-16 test system with included accessories included with the rental
    Can't find something? Contact Us

Description 

The EM Test NX7 bspr-1-300-16 is a multifunction transient immunity generator designed for demanding commercial and industrial EMC testing. It combines surge, EFT/burst, 100 kHz ring wave, and power-fail capabilities in one compact platform. The system generates combination-wave surges up to 7 kV open circuit and 3.5 kA short circuit, EFT/burst pulses up to 5.5 kV, and 100 kHz ring wave pulses up to 7 kV. Its integrated single-phase coupling decoupling network supports EUT supplies up to 300 V and 16 A AC or DC.

The NX7 supports testing to IEC/EN 61000-4-4 for EFT/burst, IEC/EN 61000-4-5 for surge, and IEC/EN 61000-4-12 for ring wave immunity. Selectable 12 Ω, 30 Ω, and 50 Ω ring wave source impedances also support applicable ANSI/IEEE requirements. Power-fail functions accommodate voltage dips, interruptions, and variations, although additional transformers or voltage sources may be required for certain IEC 61000-4-11 applications.

A color touchscreen, preprogrammed standards routines, Quick Start controls, selectable polarity, phase-angle synchronization, and integrated monitoring help operators configure repeatable tests efficiently. The included iec.control software enables remote operation, custom sequencing, and test reporting. Compatible external coupling networks expand testing to three-phase equipment, while capacitive coupling clamps and specialized networks support signal and data lines.

Renting the EM Test NX7 bspr-1-300-16 is ideal for short-term compliance projects, troubleshooting, or additional laboratory capacity. The rental includes a laptop, operating accessories, documentation, and current ISO/IEC 17025-accredited calibration unless otherwise specified. The system ships by LTL freight on pallets.

Technical Details
Electrical Fast Transients:
Burst Module
As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2
Test voltage
200 V - 5,500 V+/- 10%;
100 V - 2,750 V +/- 10% into 50 ohm
Pulse shape
5/50 ns into 50 ohm and 1,000 ohm
Rise time tr
5 ns +/- 30% into 50 ohm;
5 ns +/- 30% into 1,000 ohm
Pulse width td
50 ns +/- 30% into 50 ohm;
50 ns -15/+100 ns into 1,000 ohm
Source impedance
50 ohm
Polarity
Positive, negative
Trigger Circuit:
Trigger of bursts
Automatic, manual, external
Synchronization
0 - 360 degrees, resolution 1 degree (16 - 500 Hz)
Burst duration (td)
td = 0.10 ms - 9,999 ms
Repetition rate (tr)
tr = 10 ms - 9,999 ms
Spike frequency
f = 1 Hz - 1,000 kHz
Test duration
T = 0:01 min - 99:59 min
T > 99:59 min --> endless
Outputs:
Direct
Via 50 ohm coaxial connector
Coupling mode
L, N, PE; all combinations
EUT supply
AC: 300 V / 400 V, 50/60 Hz
DC: 300 V / 400 V,
Current: 16 A / 32 A
CRO trigger
5 V trigger signal for oscilloscope
Test Routines:
Quick Start
On-line adjustable parameters, easy-to-use
Standard Test routines
As per IEC/EN 61000-4-4, Levels 1 - 4
As per IEC/EN 61000-6-1, -6-2
As per ECE R-10 Rev5
Extended Test routines
Change voltage after T, Frequency sweep within one burst, Frequency sweep with constant number of pulses, Frequency sweep with constant burst duration, Synchronous burst release, Random burst release
Combination Wave:
Surge Module
As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2
Voltage (o.c.)
200 V - 7,000 V +/- 10%
Pulse front time
1.2 us +/- 30%
Pulse duration
50 us +/- 20%
Current (s.c.)
Max. 3,500 A +/- 10%
Pulse front time
8 us +/- 20%
Pulse duration
20 us +/- 20%
Polarity
Positive, negative, alternate
Trigger Circuit:
Release of pulses
Automatic, manual, external
Synchronization
0 - 360 degrees, resolution 1 degree
Repetition rate
max. 1 Hz (1 s - 9,999 s)
Event counter
1 - 99,999, selectable
Outputs:
Direct
Via HV connectors for external coupling networks
Coupling mode
Line to line
Line(s) to ground
EUT supply
AC: 300 V / 400 V, 50/60 Hz
DC: 300 V / 400 V,
Current: 16 A / 32 A
CRO trigger
5 V trigger signal for oscilloscope
Measurements:
CRO U-monitor
10 Vp at 7,000 V
CRO I-monitor
10 Vp at 3,500 A
Peak voltage
7,000 V in the touch display
Peak current
3,500 A in the touch display
Overcurrent protection
Breaks the Surge test when the surge current is over the limit, Limiter for differential mode, Limiter for common mode
EUT current
RMS current, Range 50 A, < +/-5%
EUT overcurrent protection
Breaks the test when the EUT current is over the limit,
Test Routines:
Quick Start
One-line adjustable parameters, easy-to-use
Standard Test routines
As per IEC/EN 61000-4-5,
As per IEC/EN 61000-6-1,
As per IEC/EN 61000-6-2,
Manual Standard Test routine
Extended Test routines
Voltage iteration after n pulses, Angle iteration stepwise, Phase angle randomiteration, Change coupling after n pulses, Change phase angle after n pulses
Pulsed Magnetic Field
as per IEC/EN 61000-4-9 Test levels 100, 300 and 1,000A/m Test level continuously adjustable under Quick Start
Dips, Interruptions, Voltage Variations
Power Fail Module:
As per
IEC/EN 61000-4-11,
IEC/EN 61000-4-29 and
IEC/EN 61000-6-1, -6-2
Channel PF1/PF2
AC voltage: max. 300 V / 400 V
AC current: max. 16 A / 32 A
DC voltage: max. 300 V / 400 V
DC current: max. 16 A / 32 A
Frequency
16 Hz - 500 Hz and DC
Switching time
> 1 us < 5 us into a 100 ohm resistive load (SVP 100)
Inrush current
> 500 A
Protection
Both channels are protected against short-circuit conditions.
Trigger Circuit:
Trigger of events
Automatic, manual, external
Synchronization
0 - 360 degrees, resolution 1 degree (16 - 500 Hz)
Repetition rate
10 ms - 9,999 s
Event duration
10 us - 99.999 s
Event counter
1 - 99,999, selectable
Outputs:
EUT terminals
L, N and PE
CRO trigger
5 V trigger signal for oscilloscope
Measurements:
EUT voltage (rms)
In the touch screen
EUT current (rms)
In the touch screen
MON V
Measurement of the EUT voltage, built-in divider:
300 V: 42,5:1, 10 V =425 Vpk,
400 V: 56.6:1, 10 V =566 Vpk
MON I
Measurement of the EUT current,
16 A: 7 A/V; 10 V =70 Apk,
32 A: 10 A/V; 10 V =100 Apk
Test Routines:
Quick Start
Standard Test routines
Extended Test routines
VoltAs per IEC/EN 61000-4-11 for AC supplies
As per IEC/EN 61000-4-29 for DC supplies
As per EN 61000-6-1, -6-2
Manual Standard Test routine
50/60 Hz magnetic field
As per IEC/EN 61000-4-8 Test levels 1, 3, 10 and 30 A/m with external current transformer MC 2630, Test levels 100, 300 and 1,000 A/m with external current transformer MC 26100
Ringwave
Ringwave Module:
As per ANSI/IEEE C62.41 and EN/IEC 61000-4-12
Test voltage
200 V - 7,000 V +/- 10%
Voltage
Wave shape (open circuit)
Rise time
0.5 us +/- 30% (first peak)
Oscillation frequency
100 kHz +/- 10%
Decaying
Peak 2 to peak 1 = 40 - 110% Peak 3 to peak 2 = 40 - 80% Peak 4 to peak 3 = 40 - 80%
Current
Wave shape (short circuit)
Rise time
0.2 us < tr <= 1.0 us
Oscillation frequency
100 kHz +/- 10%
Source impedance
12 ohm, 30 ohm, 50 ohm
Peak current
As per selected source impedance
Polarity
Positive, negative, alternate
Trigger Circuit:
Release of pulses
Automatic, manual, externa
Synchronization
0 - 360 degrees, resolution 1 degree
Repetition rate
max. 1 Hz (1 s - 9999 s)
Event counter
1 - 99,999, selectable
Outputs:
Direct
Via HV-safety lab connectors
Coupling mode
L, N, PE; line to line and line(s) to ground
DUT supply
AC: 300 V / 400 V, 50/60 Hz
DC: 300 V / 400 V,
Current: 16 A / 32 A
CRO trigger
5 V trigger signal for oscilloscope
Measurements:
CRO U-monitor
10 Vp at 7,000 V
CRO I-monitor
10 Vp at 3,500 A
Peak voltage
500 V - 7000 V in the touch display
Telecom Surge
Tsurge Module:
Test voltage (o.c.)
200 V - 7,000 V +/- 10%
Energy storage capacitor
20 uF
Polarity
Positive, negative, alternating As per ITU and ETSI recommendations
Front time
10 us +/- 30%
Pulse duration
700 us +/- 20% As per FCC part 68, Pulse B
Front time
9 us +/- 30%
Pulse duration
720 us +/- 20%
Output current @25 ohm output
5 A - 175 A (short circuit)
Rise time
5 us +/- 30%
Pulse duration
320 us +/- 20%, As per IEC 61000-4-5
Rise time
10 us +/- 30%
Pulse duration
700 us +/- 20%
Output current @25 ohm output
5 A - 175 A (short circuit)
Rise time
5 us +/- 20%
Pulse duration
320 us +/- 20%
Trigger Circuit:
Trigger of events
Automatic, manual, external
Repetition rate
max. 0.33 Hz (3 s - 999 s)
Event counter
1 - 99,999, selectable
Outputs:
As per ITU
For 2-wire T1/T2 with 25 ohm each
As per FCC part 68
For 2-wire T1/T2 with 25 ohm each
As per IEC 61000-4-5 Ed 3.0
For 4-wire T1/T2/T3/T4 with 25 ohm each
General Data
Interfaces:
Serial interface
2 x USB A for memory stick,
1 x USB B for service only,
Opto - Link to USB for remote
Lan
Ethernet for remote
Analog output
0 - 10 VDC to control an external transformer
Sys.link
26 pin high density connector to control an external coupling network
Fail inputs
EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2
Ext. Trigger
BNC Ext. Trigger IN pos slope 5 V
Ext. Sync Input
Differential input, 50 V - 690 VAC, 2 x 4 mm MC Safety connectors
Dimensions and Weight
16 A models
19"/6 HU, 500 mm deep, 19"/9 HU, with telecom module, approx. 30 kg
32 A models
19"/6 HU, 500 mm deep, 19"/9 HU, with telecom module, approx. 40 kg
Environment:
Temperature
10 C to 35 C (Operation) -10 C to 60 C (Storage)
Humidity
30 % to 70 %, non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar)
Mains:
Supply voltage
85 V - 264 V
Frequency
50/60 Hz
Power
approx. 75 W
Fuses
115 V: 2 x 4 A slow blow,
230 V: 2 x 2 A slow blow
Table top EFT setup with capacitive coupling clamp with EM Test NX5 test system

EFT/Burst Table Top Setup

When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces (including the generator), except the ground reference plane beneath the coupling clamp and beneath the EUT, shall be at least 0.5 m.

The test generator and the coupling network should be connected to the reference ground plane (acc. to high frequency requirements).
- The equipment under test must be isolated from the reference ground plane. The distance should be 10 cm.
Being part of the EUT, these requirements are also recommended for all connected cables. The EUT should only be grounded if this is recommended by the installation guideline. For safety reasons, the test without any ground connection should be conducted as well (at 100MHz 1 m ground cable lenght has an impedance of about 600 Ω)
- Whenever possible the test set-up and the cabling should always be the same; e.g. for testing power lines it would be possible to fix the cables on the test table for all tests in the same way.
- Lines under test and all other lines should be decoupled strictly.

Video Library

Video Guides
Related Videos

FAQs

This NX7 configuration performs combination wave surge, electrical fast transient/burst, 100 kHz ring wave, voltage dips, short interruptions, and voltage variation testing using one compact system. Testing to IEC 61000-4-11 requires additional external equipment for testing for most applications.

The EM Test NX7 will ship LTL freight attached to a pallet. This helps to ensure that the equipment arrives in working condition, helping to limit shipping damage. For any questions or concerns about shipping, contact our team directly at info@ts-emc.com.

Yes. The NX7 produces a 100 kHz ring wave with an open-circuit voltage up to 7 kV. Selectable 12 Ω, 30 Ω, and 50 Ω source impedances support IEC 61000-4-12 and ANSI/IEEE testing.

Yes. The rental includes a laptop with EM Test iec.control software, allowing users to run standard routines, create custom test sequences, remotely control the generator, and prepare detailed test reports.

Yes. Three-phase EUTs require a compatible external three-phase coupling decoupling network. The NX7 can automatically control supported external networks, but the required voltage, current, phase count, and coupling paths should be confirmed before ordering.

Rent the EM Test NX7 bspr-1-300-16

Weekly, two-week and monthly rentals available.

Questions?630-887-0329
EM Test IEC Test Equipment

Get the Right Accessories for Testing

Pair your rental EM Test NX5 or NX7 with compatible CDNs and accessories for mains, signal-line, and power-quality testing. We’ll help configure the equipment for your EUT and required test standard.

  • CDNs for testing 3-Phase EUT up to 125 Amps, 690 VAC
  • Capacitive Coupling Clamps for Testing I/O & Data Lines
  • Transformers and Variacs for Voltage Dips to IEC 61000-4-11

Accessories & CDNs for the EM Test NX5 and NX7

EM Test Coupling NX7 bsr-3-480-32 - Front Side

EM Test Coupling NX7 bsr-3-480-32 - Rent 3-Phase 32Amp CDN

  • Coupler for Surge, EFT, & Ringwave Pulses
  • Max 480 Volts 32 Amps AC
  • Automatic Coupler for NX5/NX7 Systems
  • CDNs for Power Lines Available up to 125 Amps
  • Current ISO 17025 Accredited Calibration
View Equipment
EM Test CCI - Front Side

EM Test CCI - Rent Capacitive Clamp EFT/Burst Testing

  • Construction as per IEC 61000-4-4 Ed.3
  • EFT/Burst Testing of Signal- and Datalines
  • Permissible Burst Voltage 7 kV
  • For Cable Diameter up to 40 mm
View Equipment
EM Test TVT 1-250-32 - Front Side

EM Test TVT 1-250-32 - Rent EM Test Tapped Transformer

  • Single Phase Automatic Step Transformer
  • Maximum 250 Volts 32 Amps
  • Designed for EM Test NX5 & NX7 Systems
  • Voltage Dips at 40 %, 70 %, 80 %, 100 %
View Equipment
Requesting Quote For
EM Test IEC Test Equipment
Need Help Choosing?

Our team can review your requirements and recommend the right equipment.