Rent 100 Amp Manual Surge CDN
In Stock - Order by 3 p.m. ships today
  • Coupler for Surge to IEC 61000-4-5
  • Max 100 Amps 690 V AC or 1,000 V DC
  • Manual Coupler for NX5/NX7 Systems
  • Includes two SCU for ANSI Coupling
  • Current ISO 17025 Accredited Calibration
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

Description Surge pulses are applied to high voltage and high current supply lines by means of standalone coupling/decoupling networks. For such testing AMETEK CTS offers the PCD 8 s-3-1000-100 for supply lines up to 3 * 690 V AC, 1.000 V DC and up to 100 A.

According to IEC/EN 61000-4-5 the pulses are manually coupled via cable loops for line to line (2 ohm/18 uF) or line to PE (12 Ohm/9 uF) coupling.

Test Setup

The AMETEK CTS PCD 8 s-3-690-1000-100 coupling decoupling network is a manual CDN for coupling Surge pulses onto high voltage / current power supply lines. High-current couplers may need to be taken to test sites where it is commonly impossible to move large installations in. For convenience, the PCD 8 s-3-690-1000-100 can be disassembled in handy parts and can easily move to other places. Wheels with braking features can be mounted to maneuvering the coupler even on ramps and uneven surfaces.

Coupling

The Surge Coupling Unit (SCU) included in the scope of delivery is mounted on top of the decoupling networks, with one SCU following coupling modes are possible:

IEC line to line (18 μF), Lx - N, Lx - Lx, IEC line to ground (9 μF), N - PE, Lx - PE

Specifications:
Model: PCD 8 S-3-690-1000-100
8 kV coupling/decoupling network max. line current 100 A (AC and DC)
AC voltage EUT
3 * 690 V (p-p)
DC voltage EUT
1.000 V
AC/DC current EUT
32 - 100 A (IEC + ANSI)
Surge coupling
as per Fig. 5/6 of IEC 61000-4-5 Ed.3,
- 18 uF capacitor via 2 ohm,
- 9 uF capacitor via 12 ohm
Technical Data:
Impulse voltage
max 8.0 kV +/- 10 %
Coupling
Manual setting with loops
Grounding
Earth terminal
Residual voltage
< 3000 V @ 6000 V surge, typical < 2000 V
Generators with 400 Volt CDN:
Lines
AC: L1, L2, L3, N, PE
DC: Use L1 and N for DC-supply
Supply voltage
max. 3 * 690 V AC (p-p) max. 1.000 V DC
EUT current
IEC + ANSI: 32 - 100 A
Generators with 300 Volt CDN:
Lines
AC: L1, L2, L3, N, PE
DC: Use L1 and N for DC-supply
Supply voltage DC
max. 1.000 V
compact NX (300 V-model)
EUT supply voltage:
max. 480 V AC rms L to L
max. 480 V AC rms L to N/PE
NSG 3040A /3060A
EUT supply voltage:
max. 480 V AC rms L to L max.
300 V AC rms L to N/PE
EUT current
IEC + ANSI: 32 - 100 A
Connector
Screw terminal rated for 200 A, 6 mm (max. 8 Nm)
General:
Input connectors
HV: 4 mm safety banana plug
COM: Fischer F-105
A suitable set of connection cables is part of delivery (PCS SET 1).
Dimensions (LxWxH)
850 mm x 520 mm x 345 mm
Weight
app. 110 Kg
Environment:
Temperature
10 C to 40 C
Humidity
30 % to 70 %, non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar)
Video Guides
EM Test PCD 8 S-3-690-1000-100 Manual Surge CDN Overview
Related Videos
EM Test PCD 8 B-3-690-1000-100 Burst CDN overview
EM Test NX7 bsprt-1-400-32 System Overview
Compact NX5 & Software Overview
EM Test Coupling NX7 32 Amp CDN Overview
Verifying EFT Pulses with the EM Test NX5