Description
Overview
The VDS 200N series is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200N series as there is a large variety of requirements. Secondly, the VDS 200N series serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200N series covers all three supply voltage categories. Their current capability ranges up to 200A depending on the model and your application.
Data SheetUser ManualApplication Note - LV 124Specifications
Common Standards |
ISO 7637-2 pulses 2b and 4, ISO 16750, GMW3172 and many others |
Output Voltage |
0V – 60V |
Output Current |
0A – 30A, continuous |
Peak Current |
15A |
Frequency Range |
DC to 100kHz |
Supply Voltage |
115/230V |
Weight |
49kg (108.02lbs) |
Dimensions |
19”/6HU |
COMMON DATA (ALL MODELS) |
|
Ripple voltage |
Ur <0.2Vp-p, frequency min. 400Hz |
Source impedance |
Zi = <10mohm |
Sinusoidal signal capability vs. Frequency *) |
Vpp max. 16V up to 20kHz Vpp max. 10V up to 30kHz Vpp max. 6V up to 50kHz |
|
Vpp max. 3V up to 100kHz via Analog In, controlled by AutoWave/AMP 200Nx only |
|
VDS 200N30.1 and VDS 200N50.1: Vpp max. 65V resp. 35V up to 50kHz with respect to the selected voltage range Vpp max. 3V up to 100kHz via Analog In, controlled by AutoWave/AMP 200Nx only |
Fuses |
Depending on VDS 200N model |
TRIGGER |
|
Automatic |
Automatic release of the events |
Manual |
Manual release of a single pulse |
External |
External release of a single pulse |
OUTPUT |
|
DUT Supply +/- |
Safety laboratory or high current connectors |
Ext. trigger |
5-15V TTL; BNC connector |
CRO Trigger |
5V TTL-signal for oscilloscope |
TEST ROUTINES FOR ARBITRARY WAVES |
|
DC source |
Max. 60V; current depending on VDS 200N model |
Functions |
Sine Wave Sweep Sine Wave (Cranking) Clipped Load Dump Jump Start Extern GM 9105P Pulse 4 Drop and Jump pulse |
Standard Test routines |
ISO 7637, Pulses 2b and 4 ISO 16750-2 Jaso Test 1 |
Service |
Service, Setup, Self test |
INTERFACE |
|
Serial interfaxe |
USB |
Parallel interface |
IEEE 488, addresses 1 - 30 |
Remote control |
To connect an external signal generator (10kohm): 0-10V / 0-50kHz max. 0.5V(p-p) / 0-100kHz |
Video
EM Test - Automotive Conducted Immunity Generators
Description: This video provides an overview on the EM Test conducted immunity test system. The three major components of this automotive EMC test equipment are the LD 200N, UCS 200N, and VDS 200N. This video provides and overview of these test systems including, ISO 7637-2 waveforms covered, accessories that come with equipment, setup, connecting all equipment, and troubleshooting. It also, provides insight into how to setup the software to allow remote testing to be conducted through laptop.