EM Test VDS 200Q100.2 - Front Side
EM Test VDS 200Q100.2 - Front
LV 124 Testing with VDS 200Q100.2 & Autowave
EM Test VDS 200Q100.2 Back
EM Test VDS 200Q100.2 - Front Above

EM Test VDS 200Q100.2

Rent 100 Amp Battery Simulator

In Stock & Ready To Ship
Orders by 3pm ship today

The EM Test VDS 200Q100.2 is a programmable automotive battery supply simulator delivering up to 100 A continuous and 300 A peak for voltage variations, dips, interruptions, and ISO 7637 testing.

Features

  • -20 to +80 Volts 100 Amps Continuous
  • Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
  • Extended Range 80 Volts 80 Amps
  • iso.control Software Included
  • Current ISO 17025 Accredited Calibration
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period

Description

The VDS 200Q series is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200Q series as there is a large variety of requirements. Secondly, the VDS 200Q series serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200Q series covers all three supply voltage categories (48 V, 24 V and 12 V). Their current capability ranges up to 100 A or more depending on the model and your application.

Specifications:
Output Voltage
- 20 Volts to +80 Volts
Output Current
0A to 100A, continuous
Peak Current
300 A for 200 ms
Frequency Range
DC to 150 kHz full signal
150 kHz to 250 kHz (40 Vpp max.)
Supply Voltage
3-phase 200/400V +/- 10% (L1, L2, L3, PE)
Weight
275 kg�
Dimensions
19"/25 HU*)
COMMON DATA (ALL MODELS)
Operation�
4- quadrant, Bipolar operation
Source impedance
Zi = Programmable <10mohm, 10-200mOhm selectable
Current limiter
3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value (not available for VDS 200Q10)
�Compensation
STD: DC - 40 kHz
HF: DC - >=150 kHz
CAP: DC - 3kHz
Output rise time
UR <10 mVp-p, frequency min. 400 Hz
Control�
Analog In
TRIGGER
Automatic
Automatic release of the events
Manual
Manual release of a single pulse
External
External release of a single pulse
OUTPUT
DUT Supply +/-
Safety laboratory or high current connectors
Ext. trigger
5-15V TTL; BNC connector
CRO Trigger
5V TTL-signal for oscilloscope
TEST ROUTINES FOR ARBITRARY WAVES
DC source
Max. 60V; current depending on VDS 200N model
Functions
Sine Wave Sweep
Sine Wave (Cranking)
Clipped Load Dump
Jump Start
Extern
GM 9105P Pulse 4
Drop and Jump pulse
Standard Test routines
ISO 7637, Pulses 2b and 4 ISO 16750-2 Jaso Test 1
Service
Service, Setup, Self test
INTERFACE
Serial interfaces
USB
Parallel interface
IEEE 488, addresses 1 - 30
Remote control
To connect an external signal generator (10kohm): 0-10V / 0-50kHz max. 0.5V(p-p) / 0-100kHz
EM Test VDS 200Q Series Datasheet
Download
EM Test VDS 200Q100.2 User Manual
Download

Video Library

Video Guides
Related Videos

Rent the EM Test VDS 200Q100.2

Weekly, two-week and monthly rentals available.

Questions?630-887-0329