ETS-Lindgren HI-6006 E-field probe 100 kHz to 6 GHz

Availability:
In Stock - Order By 3PM Ships Today!

6GHz Electric Field Probe:

  • Designed for CW Measurements to 6GHz
  • Software Provides Individual & Summerized Values
  • Frequency: 100kHz -6GHz, Range .5-800 V/m
  • Ideal for EN/IEC 61000-4-3 Field Verification
  • Arrives with Calibrated (ISO 17025) & Battery Powered 

Options/Equipment


Two FREE days transit time with every rental

Got Questions about the equipment? Get technical support

Get weekly, two week, and monthly rentals on all products

6GHz RF Equipment

Description

Overview

ETS-Lindgren's Model HI-6006 Electric Field Probe is a fully intelligent sensor enabling fast and accurate EMF measurements with industry leading performance specications. Optical coupling to a variety of readout options makes this probe ideally suited for a wide range of Field monitoring applications.

Designed to be single range reading, the HI-6006 RF eld probe can read data continuously over the entire dynamic range. Data values for each axis (X, Y, and Z) can be read individually or summed. A unique feature of the HI-6006 is the replaceable battery. This battery allows the user to replace the battery when necessary, without requiring additional calibration. Simple in-eld synchronization of the HI-6006 is all that is required for proper battery level monitoring.

The HI-6100 Field Monitor provides manual functions and programmed control via IEEE-488 and RS232 Serial Data Interfaces. Readings from up to four eld probes can be displayed simultaneously. The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series Field probes as a eld monitor in addition to its capability as a system level platform. For direct connection to a PC, either the HI-4413P Serial or the HI-4413USB interfaces are available.

Data SheetUser Manual

Specifications

Frequency Range

100kHz to 6GHz

Detection

Isotropic (X, Y and Z Axis Readings)

Frequency Response:: (Typical)

500 kHz to 2 GHz +1.0, -2.5 dB

2 to 5.5 GHz +3.5, -4.5 dB

5.5 to 6 GHz +2.0, -6.0 dB

Frequency Response with Correction:

100 kHz to 6 GHz ± 0.9 dB

Dynamic Range

0.5 to 800 V/m (Single Range)

 

Resolution 0.01 V/m

Isotropic Deviation:

± 0.5 dB @ 400 MHz
Linearity:
± 0.5 dB (1 to 800 V/m)

Sample Rate (Typical):

 70 Samples/Second Maximum

Overload Withstand: >1500 V/m CW

Battery:

4.8 V NiMH, up to 8 Hours of operation
Physical Interface: Duplex Optical Fiber (200 Micron Multimode); FSMA Connectors. Integral 1m Optical Cable

Battery Charger:

100-240 VAC Universal Input; 3-Hour Charge from Full Depletion

Cubical Housing Height: 32 mm (1.26 in)

Sensor Protection Caps Height:

43 mm (1.69 in)
Linearity:
± 0.5 dB (1 to 800 V/m)

Sample Rate (Typical):

 70 Samples/Second Maximum

Overload Withstand: >1500 V/m CW

Battery:

4.8 V NiMH, up to 8 Hours of operation
Linearity:
± 0.5 dB (1 to 800 V/m)

You may also like

Recently viewed