Haefely FP-COMB 32 Front Side
Haefely FP-COMB 32 Front
Haefely FP-COMB 32 Video Setup Guide & Overview
Haefely FP-COMB 32 Back

Haefely FP-COMB 32

Rent 3-Phase 480 Volt 32 Amp CDN

The Haefely FP-COMB 32 is an automatic three-phase coupling decoupling network for surge, ring wave, and EFT/burst testing, supporting 32 amps per phase, 480 VAC/DC, and phase-angle synchronization used with the AXOS test systems.

Features

  • Coupler for Surge, EFT, & Ringwave Pulses
  • Maximum 480 Volts 32 Amps AC/DC
  • Automatic Coupler for Axos5/8 Systems
  • Compliant to ANSI C62.41 Requirements
  • Current ISO 17025 Accredited Calibration
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period
  • FP-COMB 32#
  • AC Mains Cable
  • EUT mains cable 32Amps
  • EUT mains adapter 32Amps
  • Calibration Certificate
  • Surge Cable to Axos (5 & 8)
  • EFT/Burst Cable to Axos (5 & 8)
  • Shipping Case
  • Can't find something? Contact Us

Description

The FP-COMB 32 coupling/decoupling network – for Surge Combination Wave, Ring Wave and EFT/Burst – is fully compliant with the standard requirements of IEC/EN 61000-4-4, IEC/EN 61000-4-5 and IEC/EN 61000-4-12.

The FP-COMB 32 is controlled by the AXOS5 / AXOS8 expandable immunity test system(s). The CDN automatically changes the coupling paths, phase angles and source impedance based on test parameters set by the user via the AXOS controller – depending on the standard and coupling mode.

The FP-COMB 32 was designed to reduce residual voltage levels at the EUT mains input by integrating the proper decoupling inductors for each type of CDN application in order to meet the requirements (with regard to voltage drop at the rated current). Apart from covering the EN/IEC 61000-4-5 standard, the FPCOMB 32 also covers tests to meet surge requirements outlined in ANSI/IEEE C62.41.

Specifications
Coupling:
CDN Inputs
Banana socket front panel 5 connectors
CDN Outputs
Banana socket front panel 5 connectors
Waveforms
EFT / Burst, Surge Combination Wave, Ring Wave
Maximum EFT / Burst Input Voltage
5 kV
Maximum Surge Combination Wave Input Voltage
7 kV
Maximum Ringwave Input Voltage
7 kV
Coupling Path Selection
Automatic IEC + ANSI
Synchronization
10 V to 480 V input voltage, 0 to 359 degrees, step 1 degree
Sync. On coupling path, output BNC rear panel
Decoupling:
Voltage AC
Up to 480 V AC 16.7 Hz, 50 Hz, 60 Hz
Voltage DC
Up to 480 V DC
Nominal Current
32 A
EFT / Burst Input Voltage Range
0.2 kV to 5 kV
Surge Combination Wave Input Voltage Range
0.2 kV to 7 kV
Ring Wave Input Voltage Range
0.2 kV to 7 kV
Coupling Path Selection
Automatic
Synchronization
10 V to 480 V input voltage, 0 to 359 degrees, step 1 degree
Interface:
Extension Connector (37 pol. Sub-D connector)
Warning on AXOS Display
LEDs
Indication of coupling path Power ON LED CDN active LED
Haefely FP-COMB 32 Datasheet
Download
Haefely FP-COMB 32 User Manual
Download

Video Library

Video Guides
Related Videos

Rent the Haefely FP-COMB 32

Weekly, two-week and monthly rentals available.

Questions?630-887-0329