EMC Partner IMU4000 - Rent 4kV EFT, Surge, & Dips System

EMC Parnter 4kV Test Generator:

  • 4.1kV Surge, 4.4kV EFT/Burst, & Dips to 6Amps
  • Built-in CDN 280V/16Amps AC & 300V/16Amps DC
  • System Control Software Included with Rental
  • EMC Partner Common Mode Test System Available
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Options/Equipment


Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

IMU System Associated Equipment

IMU Series Video Guides

EMC Partner IMU Platform

This video explains the newest series of IMU test platforms by EMC Partner. It explains both the options of the IMU platform as well as applications and modular design.

IMU Series Generators

This video provided by EMC Partner, the manufacturer of the IMU/TRA test systems, provides system information about the capabilites of the IMU4000 and TEMA3000 Control software.

Data Sheet User Manual

Overview

The EMC Partner IMU4000 EMI (Optional: Common Mode) test generator is an all in one unit testing solution for testing to EFT to 4.4kV and Surge to 4.1kV with built-in single phase coupler, and Dips under 6 amps. A2LA accredited calibration is included in the EMC rental equipment price. This products "Plug and Play" architecture allows for system to automatically identify hardware then re-configure testing menu to reflect the change.

This Immunity Test Generator has been created for CE transient testing as well as fulfilling IEC basic standard requirements. The IMU 4000 includes both an Ethernet Port for control communication and test reporting that includes laboratory environmental conditions.This EMC tester is a environmentally conscience solution with low power consumption, less noise, and less heat. 

The IMU 4000 is a single unit testing system for EN/IEC 61000-4-4, EN/IEC 61000-4-5EN/IEC 61000-4-11and CE Mark. With the common mode available for testing to EN/IEC 61000-4-16 this design offers flexibility depending on testing needs. As an added bonus EMC Partner does not require proprietary software all reports are HTML based and can be viewed with web browsers.

Specifications

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11,

CE Mark, optional EN/IEC 61000-4-16

Control Features

 

 User Interface

7” Colour touch panel

Operating System

 EMC PARTNER (EPOS)

Communication Interface

Ethernet


Accessory control interface

 RS485

Atmospheric measurement 

Temperature, humidity, pressure (with accessory)

BNC monitor ports

 EUT plus IMPULSE voltage & current

Synchro on / off

0° up to 360°

Integrated CDN:

 

AC Voltage and Current 

 300V/16A; 50 to 400Hz

DC Voltage and Current

 300V/16A

Maximum EUT current

 16A

Frequency range

 DC up to 60Hz

Power frequency synchro

 DC up to 60Hz

Coupling EFT

 L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct

Coupling CWG

L-N, L-PE, N-PE, direct

Additional Capabilities

 

   EFT Burst 5/50ns:

 

  Standards

EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark

  Voltage Waveform into 50Ω load

5ns Rise Time ±30%,  50µs pulse width ±30%

  Voltage Waveform into 1000Ω load

5ns Rise Time ±30%,  50µs pulse width ±30%

  Voltage Amplitude

250-4,400V ±10%, 125V-2,200V ±10% into 50Ω

  Burst Duration  

td = 0.10ms – 30ms

  Burst Period

tr = 1ms – 1,000ms

  Frequency

f = 0.1kHz - 1,000kHz

Combination Wave Surge:

 

  Standards

EN/IEC 61000-4-5 , EN 61000-6-1, -6-2, CEMark

  Open Circuit Voltage Waveform

250V – 4,100V, Front Time1.2us ±30%, 50µs Duration ± 20%

  Short Circuit Current Waveform

125A- 2050A, 8µ Front Time ±20%, 20µs Duration ±20%

  Peak Open Circuit Voltage

250V–4100V ±10%

  Peak Short Circuit Current

125A–2050A ±10%@2Ω, 20.8-500A ±10%@12Ω

  Pulse Repetition Rate

MAX. 1Hz (1s – 999s)

Peak Voltage and Current Monitoring

5,000V, 2,500A in the LCD Display

Monitoring of EUT voltage and current

Built-in 100:1 voltage measurement

10mV/A, max. 1,000A

Dips and Interrupts:

 

Standards

EN IEC 61000-4-11 EN 61000-6-1, -6-2, CEMark

Nominal current

6 Amps Max.

Interruption Time

50µs up to 30s

Phase angle interruption

0 to 360 degrees

Rise/ Fall Time

1 to 5µs

All Accessories 

TRA3000 Full Accessory List
Item Capabilities
CDN2000-06-32 for Three Phase Coupling Add three phase capability with automatic or manual three phase coupling networks. The CDN2000A-06-32 and CDN2000-06-32, can be used for EFT, CWG surge and ring wave. Coupling path selection is either automatic under software control, or manual on the CDN front panel. All coupling networks fulfill the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards.
CDN2000A-06-63 for Three Phase Coupling

Add higher current three phase capability with automatic coupling network CDN2000A06-63. This can be used for EFT, CWG surge and ring wave. Coupling path selection is automatic under software control. This coupling network fulfills the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards.

CDN-A-3P100-480 F / F-S for 100A three Phase Coupling

Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000.

CDN-A-3P100-690 F / F-S for 100A three Phase Coupling Three phase CDN with line voltages L to N/PE=398V and L to L=690V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx.

CDN2000-06-25 Three Phase Coupling

CDN2000-06-25 can be used for Combination wave, Ring wave and EFT testing. With an EMC PARTNER oscillatory wave tester, power and up to four data lines using the 100kHz and 1MHz oscillatory waves can be tested according to IEC61000-4-18.

CN16-450C

Single phase CDN for superimposing surge and EFT into power lines. EUT power supply up to 16A at 115V 400Hz. For use ONLY with TRA2004 or TRA2006

CN2000TT MC

Test pistol for direct current injection of surge and 10/700µs according to IEC 61000-4-5. Cable length 1.5m with MC plugs. The test pistols can be used together with MIG system equipped with MC plug outputs on front panel or networks (NW).

TEST SETUP

Test package for EFT testing. This includes 1m cable with 2 x 470kOhm resistors and mechanical connections to the EFT reference plane.

VERI50EFT

50ohm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2

VERI1KEFT

1kOhm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2.

CN-EFT1000

Capacitive coupling clamp 100ohm according to IEC 61000-4-4 including 1m coax cable with BNC connectors.

CN-BALUN

Balanced/unbalanced transmission line transformer for EFT and 1MHz damped sine according to ANSI/IEEE C.37.90. Including coaxial cable with HV-BNC plugs (3x 0.5m), test tip + HV-BNC adapter (1 red, 1 black) and HV-BNC connector (2x).

ESD2000

Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0

EXT-TRA3000E

ESD discharge module to fulfill IEC 61000-4-2 requirements. Self contained unit with high voltage generation. For full details, please refer to brochure “ESD Testers”. For use ONLY with TRA3000.

ADAPTER EFT-CDN

Adapter cable which enables EFT impulses to be measured at the output of either a single or three phase CDN as required by IEC 61000-4-4 Ed.2.

CDN-UTP

The CDN-UTP is a sophisticated coupling and de-coupling network for superimposing surge impulses on balanced communication lines in accordance with IEC 61000-4-5 (Figure 12: unshielded symmetrical interconnection lines), ITU-K20, K21 and FCC part 68. It is designed for 1.2/50µs and 10/700µs pulses up to 6.6kV. CDN-UTP is also available with 4 pairs (8 lines) as the CDN-UTP8 version.

Standards

Common Standards for IMU Conducted Immunity Platform

  • IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test.
  • IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test.
  • IEC 61000-4-5: Testing and measurement techniques - Surge immunity test.
  • IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test.
  • IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test.
  • IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests.
  • IEC 61000-4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0Hz to 150kHz.
  • IEC 61000-4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.
  • IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase

You may also like

Recently viewed