Teseq NSG 3040 - Rent 4.4 kV Surge 4.8 kV EFT Generator

Teseq Multifunction Generator:

  • 4.4kV Surge & 4.4 EFT/Burst Pulse Generator
  • Built-in Coupling Network (CDN) Max 264V/16Amps 
  • Rent the CDN 3425 CCL for Data Line EFT Testing
  • Compliant to IEC and ANSI Coupling Methods 
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Options/Equipment


Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

NSG 3040 CDNs/Accessories

NSG 3040 Video & Overview

Teseq NSG 3040 Generator

This video guide shows how to setup the EM Test LD 200N load dump generator, including connections to front and back of unit, as well as controlling and modifying pulses via the iso.conrol software.

System Overview

 

Common compliant standards

Data SheetUser ManualApplication Guide - CDNs

Overview 

Teseq’s new NSG 3040 is an easy-to-use multifunction generator that simulates electromagnetic interference effects for immunity testing in conformity with international, national and manufacturers’ standards including the latest IEC/EN standards. The NSG 3040 system is designed to fulfill conducted EMC test requirements for CE mark testing, which generally include combination wave surge, Electrical Fast Transient (EFT) pulses and Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.

 Featuring an innovative, modular design, the NSG 3040 is a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories. Teseq’s well proven “Master-Slave” architecture enables individual pulse modules to be calibrated separately, with calibration data and correction factors stored on the slave controller. New modules can be easily installed with no need to return the entire system for calibration.

Using state-of-the-art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements.

A 7 Inch touch panel display with superb contrast and color makes controlling the NSG 3040 easy. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment. To achieve quick, reliable results in a development environment a standardized test can be initiated with just a few “clicks” using the integrated Test Assistance (TA) function.

Convenient touch input buttons make each parameter’s value highly visible and allow the user to quickly select and modify all settings. A stylus is not necessary, and ramp functions can be programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values can be changed easily.

With expert mode users can make manual parameter changes using the thumbwheel while a test is underway, providing an effective and fast method for identifying critical threshold values. An easily accessible SD memory card allows firmware downloads to be performed quickly and tests to be saved. In the rare case that the storage space is not sufficient, the card can be replaced by a commercially available SD memory card and existing test files can be easily copied onto the larger SD card.

The NSG 3040 has an Ethernet port for external PC control. The Windows-based control software simplifies test programming and compilation of complex test sequences with various types of tests. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests

Specifications

Common Standards

EN/IEC 61000-4-4,  EN/IEC 61000-4-5EN/IEC 61000-4-11, & CE Mark

Integrated CDN

 

  AC Voltage             

24-260 Vrms, 50/60 Hz (phase-neutral), 400 Hz max

  AC Current

16 Amps, Max 25 Amps for 15 min.

  DC Voltage

0-260 VDC, Max

  DC Current

16 Arms, Max 25Arms for 15 min.

EFT Burst 5/50ns:

 

  Standards

IEC 61000-4-4, EN 61000-4-4, CE Mark

  Voltage Waveform into 50Ω load

5ns Rise Time ±1.5ns,  50µs pulse width ±15ns

  Voltage Waveform into 1000Ω load

5ns Rise Time ± 1.5ns,  50µs pulse width ± 100/-15ns

  Voltage Amplitude

± 100V – 2.4kV into 50Ω, ±200V – 4.8kV into 1000Ω

  Burst Duration

1µ to 1999 s, single pulse and continuous

  Burst Period

1 ms to 4200 s

  Frequency

100 Hz to 1000 kHz

Combination Wave Surge:

 

  Standards

IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45

  Open Circuit Voltage Waveform

1.2µs Front Time ± 30%,  50µs Duration ± 20%

  Short Circuit Current Waveform

8µ Front Time ± 20%, 20µs Duration ± 20%

  Peak Open Circuit Voltage

±200V–4.4kV in 1 V step

  Peak Short Circuit Current

±100A–2.2kA

  Pulse Repetition Rate

10 s, up to 600 s

Weight

25 kilograms, 55 pounds

Dimensions

45x22x56 cm, 18x9x22 inches

CDNs

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

Rental Couplers NSG 3040:

Coupler Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

  

All Accessories

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

NSG 3040 Full Accessory List

Item Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

CDN 8014/8015

Capacitive coupling clamp for burst

CDN 163

Burst coupling network 100 A per phase (coupling all to ref ground)

CDN 117/118

Coupling networks for signal-/data lines (surge)

CAS 3025

Burst/EFT verifi cation set

MD 200

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

MD 200A

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

INA 165

Conducted stand-off

INA 166

Brackets 5 HU for rack mounting

INA 6501

Manual step transformer, 16 AAC, 0/40/70/80%

INA 6502

Automatic step transformer, 16 AAC, 0/40/70/80%

VAR 6501

Automatic variable transformer, 7.5 A

VAR 6502

Automatic variable transformer, 2 x 16 A

VAR 6503

Manual variable transformer, 7.5 A

MFO 6501

Manual magnetic fi eld option -4-8

MFO 6502

Automatic magnetic fi eld option -4-8