Com-Power LI-220C - Rent 50µH 9kHz - 30MHz LISN 20A

50µH 20Amp LISN:

  • Frequency Range: 9 kHz to 30 MHz
  • Fully Compliant with CISPR 16-1-2/ANSI C63
  • Inductors: 250 & 50 Microhenry (air-core)
  • Maximum 270VAC/20Amps & 380VDC/14Amps
  • “Air-core” Inductors to Prevent Saturation

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Associated Rental Emissions Equipment

Description

Overview

The LI-220C Line Impedance Stabilization Network (LISN) is in full compliance with both CISPR 16-1-2 and ANSI C63.4. It provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.

Data SheetUser Manual

Specifications

Common Standards

CISPR 16-1-2, ANSI C63.4

Type

50Ω / 50 μH + 5Ω (CISPR), 50 μH & 250 μH(ANSI)

Frequency Range

9 kHz to 30 MHz

Insertion Loss (Voltage Division Factor)

9 kHz - 150 kHz <6.5 dB to <0.5 dB (increasing linearly with log of freq)

150 kHz - 30 MHz <0.5 dB

Isolation

9 kHz - 150 kHz >10 dB to >60 dB (increasing linearly with log of freq)

150 kHz - 30 MHz >60 dB

Voltage Rating

270 VoltsAC (rms), 380 VoltsDC (Line to Ground)

Current Rating

20 AmpsAC (rms), 14 AmpsDC