Haefely AXOS5 - Rent 5kV Surge & EFT Generator

Availability:
In Stock - Order By 3PM Ships Today!

Haefely 5 kV Transient Generator:

  • 5kV Surge & EFT/Burst Pulse Generator
  • Built-in CDN: 264V/16Amps AC & 220V/10Amps DC
  • Easy to Use & 3-Phase CDN FP-COMB 32 Available
  • Front Panel Voltage & Current Monitoring Ports
  • Current ISO 17025 accredited Calibration

Options/Equipment


Included Items, View Packing List
Got Questions?
Get technical support
Price:
Sale price$1,350
Request A Quote

Haefely AXOS Associated EMI Equipment

AXOS5 Video Guides

AXOS5 Surge & EFT Testing (includes CCL)

This video includes the generic test setups of the Haefely AXOS5 test system for both combination wave surge testing as well as EFT or burst testing including using the IP4B capacitive coupling clamp (CCL). 

Haefely AXOS Platform Overview

This video provided by Haefely, the manufacturer of the AXOS5 and AXOS8 test systems, provides system information and a brief overview of capabilities and connections on front and back.

Data SheetUser Manual

Overview

The Haefely Axos 5 EMI (conducted immunity) test generator for 5kV Surge and EFT with a built-in single phase coupling/decoupling network. This compact Haefely product provides safe and reliable operation by using safety interlock, warning lamp and emergency stop functions helping to ensure safe use.

A major advantage of this Immunity Test Generator is the ability to monitor voltage and current through front of the test system. This allows for effective verification of waveform without need for external attenuator. Take advantage of pro-rated daily rates after the first month and quick delivery!

This Immunity Test Generator is designed for EFT / Burst, Surge, Magnetic Field and AC & DC Dips and Interrupts allowing for a diverse range of applications. This pulse generator is easy to operate with manual and automated test mode and software assisted test preparation. The touch screen provides efficient and effective manipulation of testing criteria to meet or a diverse set of testing needs.

The Axos 5 expandable functionality allows for quick and completely automated testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and EN/IEC 61000-4-11 and CE Marking. The unit also includes an integrated single-phase coupling decoupling network (CDN) for EMC testing applications up to 16A. The AXOS unit can either be operated via front panel by large color graphic interface or remotely from the PC for added flexibility. 

Specifications

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11 & CE Mark

General Data

 

Control Power

85 V – 264 V, 50/60 Hz

User test storage

 unlimited

Remote interface

Ethernet, RJ45

Display

 7“ / 800x480 / 24 bit with touch-screen

AUX. interface

8D-sub 37p for external CDN, external transformer etc

Synch input

 BNC, 10 V – 264 V AC

External start / stop input

5 V TTL, starts / stops predefined test sequence

Dimensions

 45 x 18 x 49cm, 17.11 x 7.02 x 19.29 inches

Control Power

85 V – 264 V, 50/60 Hz

Weight

 25kg, 55 lbs

IEC 61000-4-4

Output voltage

 0.2 – 5.0 kV ±10% at coaxial output

Polarity

pos / neg / alternate

Output impedance

 50 Ohms

Rise time

5 ns ±30%

Impulse duration

50 ns ±30% at 50 Ohm 50 ns –15 +100 ns at 1000 Ohm

Burst mode

normal, continuous, real, random

Spike frequency

1 Hz – 1 MHz

Burst duration

10 us – 1 s

Integrated single phase coupling / decoupling network

264 V AC / 16 A 220 V DC / 10 A

Output voltage

 0.2 – 5.0 kV ±10% at coaxial output

IEC 61000-4-5

Output voltage

0.2 – 5.0 kV ±10%

Voltage Rise Time / Impulse duration

1.2 μs ±30% / 50 μs ±20%

Output Current

0.1 – 2.5 kA ±10%

Current Rise Time / Impulse Duration

8 us ±20% / 20 us ±20%

Polarity

pos / neg / alternate

Output Impedance

2Ohms & 12Ohms Automatic

Phase Sync

0 – 359°with 1°steps or asynchronous mode

Integrated Single Phase CDN

264V AC / 16A 220V DC / 10A

All Accessories

Item Capabilities
DIP 116 Automatic Dips Transformer 16 A 40/70/80%
FP-EFT 32M

3-Phase CDN EFT/Burst 32 A / 690 V

FP-EFT 100M2

3-Phase CDN EFT/Burst 100 A / 690 V

IP4B Capacitive Coupling Clamp for EFT/Burst 

FP-COMB 32

Automatic 3-Phase / 32A CDN Surge and EFT/Burst 2

FP-SURGE 100M2

3-Phase CDN Surge 100A / 690 V

PCD 121

Symmetrical Data & Control Line Coupler

PCD 126A

Asymmetrical Data & Control Line Coupler

DEC 5

Symmetrical Data & Control Line Decoupler

DEC 6

Symmetrical Data & Control Line Decoupler

DEC 7

Asymmetrical Data & Control Line Decoupler

MSURGE-A

Magnetic Field Test IEC / EN 61000-4-9

VTM 15000

Isolation Test 1.2/50 us up to 10 kV

VTM 15000/05

Isolation Test 1.2/50 us up to 10 kV / 0.5J

PDP 8000

HV Differential Probe 1000:1 for Surge

CP 101

Current Probe Model for Surge

ES

External Emergency Stop Switch P12

WL

External Warning Lamp P12

 

Common Standards

Axos 5 Testing Standards:

  • IEC/EN 61000-4-4 EFT / Burst
  • IEC/EN 61000-4-5 Surge Edition 2 & 3
  • IEC/EN 61000-4-9 Imp Magnetic Field
  • IEC/EN 61000-4-11 AC Dips and Interrupts
  • IEC/EN 61000-4-29 DC Dips and Interrupts
  • IEC/EN 61000-6-1 Generic Residential
  • IEC/EN 61000-6-2 Generic Industrial
  • IEC/EN 60335-1 Household
  • IEC/EN 60601-1 Medical
  • and many more