Teseq NSG 4070

Rent Conducted RF Immunity Test System
  • Built-in 80 Watts 150 kHz to 230 MHz Amplifier 
  • 1 GHz Signal Generator & 3 Power Meter Inputs
  • Preprogrammed Test Routines/Sequences
  • Includes Laptop with iec.control Software
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Power Cable
  • Printed Manual & Calibration Documentation
  • Pasternak PE 7021-6 6dB & 20dB Attenuator 
  • N Female, N Male, BNC, Adapters (3)
  • 50 Ohm Termination Load
  • 9 Pin D Shaped Serial Cable
  • N to N Cable LE 239 & 12inch
  • Silver U Shaped Jumper
  • BNC to BNC Cable
  • USB Stick with Software
  • Ethernet Cable
  • USO USB Box & 10m. Cable
  • N to BNC Cable
  • USB Cable
  • Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The heart of the device is the signal generator, which generates the sinusoidal signal over the wide frequency range from 4 kHz to 1 GHz and in the level range -60 dBm to +10 dBm. The built-in modulator allows amplitude and pulse modulation. The NSG 4070C contains extended parameters for pulse modulation and allows up to three envelopes to be interleaved. One input allows modulation from an external source.

The output of the signal generator is connected to the internal power amplifier via a bridge. Next to the amplifier a directional coupler is connected to measure the forward power. The NSG 4070C-60 and NSG 4070C-110 additionally measure the reverse power at the internal directional coupler. All NSG 4070 devices can measure forward and reverse power via an external directional coupler. For this application, power meter inputs 2 and 3 are located on the front panel. The power meter input 1 is intended for adjusting the target value and for connecting the current probe.

 The EUT monitoring interface allows the simple and fast integration of the interfaces of the EUT to be monitored. The TTL inputs and outputs of the NSG 4070 can be used to integrate additional equipment for monitoring test specimens. The optical EUT monitoring input can detect the status of an indicator lamp. When using the extensive EUT monitoring functions, the user receives a meaningful test result with assignment of the events to the respective test frequency. Subsequent design changes to the EUT can thus be qualified more quickly.

Technical Specifications:
RF Generator
Frequency range:
4 kHz to 1 GHz
Resolution:
1 Hz
Reference frequency:
10 MHz
Aging:
25 ppm
RF Level
Level range:
60 dBm to +10 dBm
Resolution:
0.1 dB
Settling time:
10 ms
Amplitude modulation
Modulation depth:
0 to 100%
Modulation frequency range:
1 Hz to 50 kHz
Frequency resolution:
1 Hz
Pulse modulation
Rise/fall time (10%/90%):
< 1 us
Modulation frequency range:
0.01 Hz to 1 MHz
Frequency resolution:
0.01 Hz
Duty cycle:
0.1% to 100%
External modulation
Delay time:
< 1 us /180 Degrees
Period:
min. 20 us
Pulse width:
min. 10 us
Power Meter
Frequency range:
4 kHz to 1 GHz
Linear measurement range
-35 dBm to +27 dBm (NSG 4070C-60 and NSG 4070C-110:-40 dBm to +27 dBm)
channel 2,3:
45 dBm to +20 dBm
Max. input/no damage channel 1-3:
+28 dBm
Noise level:
>5 dB below the measurement range
Input return loss:
>20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
Connector:
BNC socket, 50 Ohm
Accuracy 10 to 30�C:
<0.5 dB, typ. <0.3 dB
Power Amplifier
Nominal output power:
80 W
Frequency range:
150 kHz to 230 MHz
Type:
single band, class A
Input/output impedance (nominal):
50 Ohms
Input return loss (minimum):
10 dB
Output return loss without damage:
0 dB
Gain (minimum):
50 dB
Gain flatness (maximum):
+/- 3 dB
Saturated output power (minimum):
49 dBm
Linear output power (minimum):
48 dBm
Input power without damage (maximum):
+10 dBm
Harmonic distortion at linear output power (typical):
< -20 dBc
Analog Ports
Front panel:
Generator output:
N socket 50 Ohms, 4 kHz to 1 GHz
Power amplifier input:
N socket 50 Ohms, max. +10 dBm
Power amplifier output:
N socket 50 Ohms
Power meter channel 1 to 3:
as defined in chapter Power meter
Back panel
Monitoring input analog:
BNC socket, 0 to 24 V Ri=15 kOhms, 6 mV resolution
External modulation input:
BNC socket, impedance >10 kOhms, level: 1 Vpp to get 100% AM, 1 Hz to 50 kHz
10 MHz reference output:
BNC socket, approx. 1 Vpp/50 Ohms
General Data
Operating temperature range:
0 C to 40 C
Storage temperature range:
: -20 C to 60 C
Relative humidity:
95 %/30 C (no moisture condensation)
EMC:
DIN/EN 61326-1:2006
Shock:
DIN/EN 60068-2-27
Vibration:
DIN/EN 60068-2-6
Protection class:
DIN/EN 61010-1/IEC 61010-1
Mechanical Specifications
Size (W x H x D):
45 cm (19 Inches) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
Weight:
approx. 15 kg (with internal power amplifier),
approx. 8 kg (without internal power amplifier)
Size of cardboard box:
80 cm x 61 cm x 34 cm (also for options ATN 60xx and/or LE 4070 additional space available)
Weight of cardboard box:
approx. 8 kg (empty)