Description
Overview
The Teseq CDN3061 single phase coupler for use with the NSG 3060 Transient Immunity Tester for EFT, Surge and 100kHz Ringwave. This coupling/decoupling network is designed to be used with the NSG 3060 Immunity Test System. It comes with an ISO 17025 accredited calibration, technical support, and two free days transit time. This Teseq product is designed for maximum reliability, a diverse set of test setups, and both IEC & ANSI coupling methods.
The CDN 3061 network features a module for the power quality test required by EN/IEC 61000-4-11 and IEC/EN 61000-4-29. Automated variac accessories are available for connection to the CDN to perform the variation test described in IEC/EN 61000-4-11. Voltage variation test parameters are set via the generator’s user interface. Over temperature protection for the CDN 3061, which allows short term operation at currents exceeding the nominal rating, prevents damage to internal components.
This EMC immunity test product can be rented by itself or part of a system as the NSG 3060 CDN 3061. This Teseq tester provides coupling for both IEC and ANSI standards. The CDN 3061 utilizes the latest electronic component technology which guaranties remarkable phase coupling accuracy which exceeds the standard’s requirements.
Data Sheet Application Guide - CDNsSpecifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN 61000-4-12 ANSI C62.41, C62.45, UL 1449 |
External Single Phase CDN 3061: |
Other optional CDN’s (CDN 3063, 3083) are available also |
AC Voltage |
30-270 VAC |
AC Current |
16 A, Max 25A for 10 min. |
DC Voltage |
0-270 VDC, Max |
DC Current |
16 A, Max 25A for 10 min. |
Dips and Interrupts: |
INA 6502 external variac is available as a separate option |
Technical information |
|
EUT supply: 1-phase (P/N/PE) |
EUT VAC30 to 270 VAC rms, line to neutral, 50/60 Hz (below 30 V synchronization not guaranteed, asynchronous mode only) EUT VDC 0 to 270 VDC DC - 65 Hz with no EUT loss, 400 Hz max. with EUT power loss |
EUT current: |
1 x 16 A rms continuous (over temperature protection) 1 x 25 A rms for approx. 10 min (over temparature protection) |
Burst voltage: |
Up to 4800 V |
Surge voltage: |
Up to 6600 V |
Connections: Front panel |
HV-surge pulse input from generator (Fischer connector) EFT connector from generator (SHV connector) Ground/PE connection |
Rear panel |
Cable connector for EUT supply input and output |
Instrument supply: |
85 to 265 VAC, 50 / 60 Hz |
Decoupling attenuation |
Residual pulse voltage on EUT power supply inputs 15% max. Residual voltage on non-pulsed power supply inputs 15% max. |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
Full CDN List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 3063-C32 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A |
CDN 3063-C63 |
Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verification set |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 3005-S16 |
Automatic variable transformer, 1 x 16 A |
VAR 3005-D16 |
Automatic variable transformer, 2 x 16 A |
MFO 6501 |
Manual magnetic field option -4-8 |
MFO 6502 |
Automatic magnetic field option -4-8 |
INA 701 |
Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9 |
INA 702 |
Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator |
INA 752 |
Pulse shape adapter |