ETS-Lindgren/EMCO 3810/2NM
Related Equipment
Description
The ETS-Lindgren Model 3810/2 Line Impedance Stabilization Network (LISN) is a two-channel low pass filter network designed to isolate the Equipment Under Test from an external power source while steering any radio frequency signals from the power line to a 50-ohm port.
The Model 3810/2 Line Impedance Stabilization Network (LISN) is designed for use in Installation Category II and Pollution Degree II per lEC-1010 and IEC-664. When installing in a cabinet, make sure that the convection around the product is not restricted. The ambient temperature outside the cabinet must be less than the maximum operating temperature of the Model 3810/2 by 4°C for every 100 watts dissipated in the cabinet. If the total power dissipated in the cabinet is greater than 800 watts, then forced convection must be used.
The Model 3810/2 is nominally designed for a 10 ampere current capacity. Maximum line-to-line voltage must not exceed the voltage rating of the power outlet provided on the front panel.
- Specifications:
- Type
- 50 Ohm / 50 uH + 5? (CISPR), 50 uH & 250 ?H(ANSI)
- Frequency Range
- 9 kHz to 30 MHz
- Insertion Loss (Voltage Division Factor)
- 9 kHz - 150 kHz <6.5 dB to <0.5 dB (increasing linearly with log of freq)
- 150 kHz - 30 MHz <0.5 dB
- Isolation
- 9 kHz - 150 kHz >10 dB to >60 dB (increasing linearly with log of freq)
- 150 kHz - 30 MHz >60 dB
- Voltage Rating
- 270 VoltsAC (rms), 380 VoltsDC (Line to Ground)
- Current Rating
- 20 AmpsAC (rms), 14 AmpsDC