FCC Part 15 Pre-Compliance Emissions Kit
Related Equipment
This test package of products is designed for pre-compliance emissions testing to FCC Part 15. This includes a Siglent SSA series spectrum analyzer, Tekbox TBFL1 transient limiter, and EMCO/ETS-Lindgren LISN designed for a maximum of 10 Amps EUT. The Siglent spectrum analyzer can also be rented with the near field probe kit allowing for pre-compliance radiated emissions testing as well.
- Specifications:
- Type
- 50 Ohm / 50 uH + 5? (CISPR), 50 uH & 250 ?H(ANSI)
- Frequency Range
- 9 kHz to 30 MHz
- Insertion Loss (Voltage Division Factor)
- 9 kHz - 150 kHz <6.5 dB to <0.5 dB (increasing linearly with log of freq)
- 150 kHz - 30 MHz <0.5 dB
- Isolation
- 9 kHz - 150 kHz >10 dB to >60 dB (increasing linearly with log of freq)
- 150 kHz - 30 MHz >60 dB
- Voltage Rating
- 270 VoltsAC (rms), 380 VoltsDC (Line to Ground)
- Current Rating
- 20 AmpsAC (rms), 14 AmpsDC