Teseq CDN 3083-B100 - Rent 100 Amp 3-Phase Burst CDN

Teseq 100Amp 3-Phase Burst CDN:

  • Manual Burst Coupler for Teseq NSG 3060/3040 
  • 3-Phase CDN Max 690V/100Amps AC/DC
  • Can be used with a Variety of Generator
  • Compliant to IEC 61000-4-4 EFT/Burst Testing
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Transient Equipment

Description

Overview

The CDN 3083-B100 is a manual 100 A three-phase EFT / burst coupling decoupling network (CDN), designed for testing Equipment Under Test (EUTs) up to 690 VAC (L-L or L-PE) and up to 1000 VDC (L-L or L-PE), and used for coupling fast transients (burst pulses) up to 8.8 kV (5 / 50 ns – 50 Ω) into the supply lines of the EUT.

The CDN 3083-B100 is a high quality and affordable solution, ideal for industries and applications that require higher AC and DC voltages and currents, including power & telecom industry, renewable energy applications (smart grid, inverters, solar, energy monitoring devices), electric vehicle and charging stations.

The light weight (5 kg), small size (410 x 170 x 190 mm), and portable design of the CDN takes into consideration the requirements of the latest IEC 61000-4-4 edition 3 standard, including the various test setups, the need for minimum distance between coupling devices and EUTs, and the need to mount coupling decoupling sections directly to the reference ground plane.

Whether you are testing large or small table top equipment, fl oor standing or equipment with elevated cable entries, setting up and handling has never been so fast and easy. The light weight and portability of the CDN 3083-B100 enables you to quick and easily place the CDN at the right position and ensure that minimum distances between CDN and EUT as required by the standard are met. The metal housing construction is such that users can simply place the CDN 3083-B100 directly on the ground reference plane as required by the standard, and guarantees an excellent HF earthing.

High inrush currents or pulse-shaped peak currents can be handled with ease.

In addition, a built-in thermometer enables the heating effect to be monitored. The high quality components used in the design of the CDN enable users to even test for short durations at much higher currents than specifi ed. The current limitation is largely a matter of thermal loading and ambient temperature.

Data Sheet User Manual Application Guide - CDNs

Specifications

Common Standards

EN/IEC 61000-4-4

AC Voltage                

690 VAC RMS

AC Current

100A continuous

DC Voltage

1000 VDC

DC Current

100A continuous

EFT/Burst 5/50ns

Max 8.8kv


Control

Automatic through the NSG3060

Connection to generator

Fischer S105 A 004/10.7

Weight

5 kg approx., 11 pounds

Dimensions

41x17x19 cm, 16x7x7 inches

All Accessories

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

Full CDN List
Item Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

CDN 3063-C32

Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A

CDN 3063-C63

Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A

CDN 8014/8015

Capacitive coupling clamp for burst

CDN 163

Burst coupling network 100 A per phase (coupling all to ref ground)

CDN 117/118

Coupling networks for signal-/data lines (surge)

CAS 3025

Burst/EFT verification set

MD 200A

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

INA 6501

Manual step transformer, 16 AAC, 0/40/70/80%

INA 6502

Automatic step transformer, 16 AAC, 0/40/70/80%

VAR 3005-S16

Automatic variable transformer, 1 x 16 A

VAR 3005-D16

Automatic variable transformer, 2 x 16 A

MFO 6501

Manual magnetic field option -4-8

MFO 6502

Automatic magnetic field option -4-8

INA 701

Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9

INA 702

Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator

INA 752

Pulse shape adapter

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

 

  • EMC Directives
  • UN ECE R10 (Automotive)
  • IEC/EN 61000-4-4
  • ANSI/IEEE C62.41
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 50370
  • EN 61643
  • EN 300386-2
  • EN 300386 V1.3.2
  • EN 301489-1
  • EN 301489-7
  • EN 301489-17
  • EN 301489-24
  • IEC 60255-1
  • IEC 60601-1-2
  • IEC 61009-1
  • IEC 61326
  • IEC 61850-3