ECAT E411 - Buy & Rent 4.4kV EFT/Burst Module IEC 61000-4-4

Availability:
In Stock - Order By 3PM Ships Today!

ECAT EFT/Burst Module:

  • 4.4kV EFT/Burst Generator Module
  • IEC 61000-4-4 ed.3 & ANSI C37.90 Solution
  • Can be used with 1-Phase/3-Phase CDNs
  • Easily Integrated into Existing ECAT Systems

Price:
Sale price$4,000
Request A Quote

Common Immunity Accessories

Description

EFT/Burst ECAT Module Features: 

      • IEC 61000-4-4 ed.3 & ANSI C37.90 Solution
      • ISO 17025 Calibration Included
      • 4.4kV Generator & Built-in Pulse Monitor
      • Can Be Rented w/without E103 System
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller

Overview

The ECAT E411 made by Thermo Fisher Scientific / Keytek is designed for electrical fast transients (EFT) and Burst testing to 4.4kV. This Thermo Fisher Scientific EMI immunity test equipment comes with an  A2LA accredited calibration included with rental or purchase. The E411 plug-in module requires the ECAT E103 control unit.

This Thermo Fisher Scientific / Keytek EFT/Burst Test Equipment provides single port testing and allows changing tests modes without switching off power to the equipment under test (EUT). This helps testing with the E411 be conducted efficiently without re-initializing the EUT between tests. This unit can be easily integrated with preexisting ECAT system by sliding the E411 into open bay of the ECAT E103 control unit.

The ECAT E411 is designed to test EN/IEC 61000-4-4 ed.3 and ANSI C37.90. All of our E411 are upgraded to meet the latest version of IEC 61000-4-4. The modular system provides the ability to be upgraded providing the ability to upgrade test capabilities to meet the newest standard. This cost effective solution is in excellent working conduction and software can be acquired with purchase.
Data Sheet

Specifications

E411 EFT Generator

 

Standards

EN/IEC 61000-4-4 ed. 3, ANSI C37.90

Burst Voltage

200V to  4.4kV

Burst Voltage Resolution

5V

Burst Frequency

Adjustable from  1kHz to 1 MHz to a full 4.4kV


Burst Duration

1.0ms to 20ms; 1ms  resolution

Burst Test Length

1s to 999s

Weight

11kg, 25lbs

Dimensions

21x21x52 cm, 8x8x20 inches

ECAT Series

Common Modules

 

ECAT Series Full Accessory
Item Capabilities
ECAT Model E411 EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
ECAT Model E412 EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following:
ECAT Model E421 FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k
ECAT Model E501B Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA
ECAT Model E502B Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT
ECAT Model E503 Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
ECAT Model E504A Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module)
ECAT Model E505A Plug-in module that produces the lightning surge waveforms required by FCC Part 68
ECAT Model E506-4W Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing
ECAT Model E508 and E508-12P Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE
ECAT Model E510A Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA
ECAT Model E511 Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards
ECAT Model E513 Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864
ECAT Model E514 Surge simulator for 10/1000 µs current waves
ECAT Model E515 Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE
ECAT Model E518 Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT
ECAT Models E521 and E522 Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits).
ECAT Model E551 A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5
ECAT Models EP61 and EP62 Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A
ECAT Model E455x Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5

  

You may also like

Recently viewed