ECAT E508

RENTAL

ECAT E508

10x360 Waveform generator for testing per GR 1089-CORE, requires the E103 controller.



10x360 Waveform generator for testing per GR 1089-CORE, requires the E103 controller.

Telecom Surge Module – E508

 

Standards

GR 1089-CORE

Open Circuit Voltage Waveform

10/360µs

Short Circuit Current Waveform

10/360µs

Peak Open Circuit Voltage

50-1100V,-0±15% in 1 voltage steps

Peak Short Circuit Current

100A/side

Pulse Repetition Rate

1 shot/50 seconds

Weight

11kg,25 lb

Dimensions

21x42x52cm, 8x16x20 inches

E508 Brochure