Description
The ECAT E513 and E103 by Thermo Fisher Scientific/Keytek are designed as a voltage ramp generator for testing to a variety of Underwriter Laboratories (UL) standards. This system rental is a combination of the ECAT E103 control unit and E513 voltage ramp generator. This immunity test system provides single port testing and allows changing test modes without switching off power to the equipment under test (EUT).
- Specifications
- Voltage Ramps
- 0.1kV/us, 0.5kV/us, 1.0kV/us, 5.0kV/us, 10kV/us, 0.1kV/us is linear to 2.5kV; all other ramps are linear to 3.0kV.
- Voltage Durations
- 65us for 0.1kV/us; 40us for 0.5kV/us and 1.0kV/us; 5us for 5kV/us and 10kV/us
- Current Duration
- 45 us at 0.1kV/us; 40us at 0.5kV/us and 1.0kV/us; 4us at 5kV/us and 10kV/us
- Open-circuit Voltage
- 0-3000 Volts; +/- 5% in 1 Volt Steps
- Short-circuit Current
- 50A, +/- 10% when the peak open-circuit voltage is set to 3.0kV
- Minimum System Requirements
- E1000 series control center with blank wall plug-in module
- Weight
- 53kg (24lbs)
- Dimensions
- 21 X 52 X 21cm (8.25 X 20 3/8 X 8.5)