The EM Test CA LV 148 Set provides dedicated accessories for LV 148 automotive electrical testing, supporting standardized voltage profiles, disturbance coupling, and repeatable validation of 48 V vehicle electronics.

Features

  • 10 Ohm & 100 Ohm Power Calibration Loads
  • Designed for up to 48 Volt Battery Lines
  • Low Inductive, High Precision Load Resistor
  • Rented with the EM Test PFM 200N100
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period

Description

The CA LV 124 set includes four load resistors for the verification of the pulses E10 and E13 of the LV 124 (2013). The load resistors CA LV124-P1R and CA LV124-P100R are used for power line verification. For verification the 16 signal and data lines the CA LV124-D1R and CA LV124-D1000R are used.

As the LV 148 standard requires no data line verification, the CA LV148 consists of a CA LV148-P10R and CA LV148-P1000R for power line verification.

Specifications:
NSG 5500
Instrument power supply:
100 to 120 VAC �10%, 47 - 63 Hz
DUT supply:
From an external source, e.g. battery or PA 5840 power amplifier / battery
Computer interface:
simulator
Input DC voltage range:
60 V max
DC current:
100 A (250 A for 200 ms)
Voltage drop of battery Switch:
< 2 V @ 100 A; about 1.5 V @ 25 A
Battery switch on/off time:
About 2 us (1 Ohm load)
Protection class:
IP20
LD 5550
Pulse amplitude:
20 to 200 V in 0.1 V steps +/-5%
Clamping:
10 to 100 V +/-5%
Pulse 5b overshoot typ. <2%/2V
Impedance (Ri):
0.5 to 10Ohms in 0.25Ohms steps; 30.5Ohms, 40Ohms +/-10%
Pulse rise time:
0.5 to 10 ms +/-10%
<0.5 ms (�10% + 50us)
+/-10% >=50 V pulse amplitude
+/-20% <50V pulse amplitude
Pulse repetition:
15 to 600 s in 0.1 s steps, pulse repetition depends on pulse energy
Pulse modes:
Single, continuous, programmed 1 to 9,999
FT 5531
Pulse Amplitude � 150ns pulse
50-800V EUT / 50-600V BNC
Pulse Amplitude � 100ns pulse
50-600V
Impedance
50 ?
Pulse Rise Time
5 ns
Pulse Width
150 ns / 100 ns
Pulse Frequency
1 � 100 Khz
Burst Interval
0.01 to 99.9 ms
Pulses per burst
1 � 200
Burst Repetition
90 ms � 99.9 s in 10 ms steps