EM Test UCS 500N5E
Included Accessories
Can't find something? Contact UsRelated Equipment
Description
The UCS 500N5 ultra-compact simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/product family standards. The UCS 500N5 is the most economic solution for tests during development as well as for full-compliant immunity tests and CE Marking for single phase DUT with the ability to be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.
EM TEST supplies a large range of accessories for the various applications such as magnetic field tests.
Benefits
The UCS 500N5 includes everything necessary to conduct fully compliant tests. The power mains supply for the controls and for the DUT is separate to render it more flexible to use with different DUT supply voltages. The UCS 500N5 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.
Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N5 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.
Operation
Front panel menu and function keys enable the user to program his test routines quickly and accurately. The cursor allows fast control of all test parameters of the programmed routine, thus test procedures are simplified and confidence is generated that every step is carried out correctly.
Software
Outstanding user convenience, clearly structured windows and operation features and the EM TEST standards library along with the flexibility to generate user specific test sequences very easily are the main features of iec.control software. The software is automatically configured according to the connected EM TEST generators. Extensive reporting capabilities help the user to create test reports that meet international requirements.
iec.control is supported by Windows 2000, Windows XP, Windows Vista and Windows 7. Remote control is achieved either via USB or GPIB. iec.control supports a wide range of GPIB cards of National Instruments.
- Technical Specifications:
- Electrical Fast Transients
- Burst Module
- As per EN/IEC 61000-4-4 and EN 61000-6-1, -6-2
- Test voltage
- 200V - 5,500V +/- 10%;
100V - 2,750V +/- 10% into 50ohm - Pulse shape
- 5/50ns into 50ohm and 1,000ohm
- Rise time tr
- 5ns +/- 30% into 50ohm;
5ns +/- 30% into 1,000ohm - Pulse width td
- 50ns +/- 30% into 50ohm;
50ns -15/+100ns into 1,000ohm - Source impedance
- 50ohm
- Polarity
- Positive/negative
- Trigger Circuit
- Trigger of bursts
- Automatic, manual, external
- Synchronization
- 0 - 360 degrees, resolution 1 degree (16 - 500Hz)
- Burst duration
- td = 0.10ms - 999ms
- Repetition rate
- tr = 10ms - 9,999ms
- Spike frequency
- f = 0.1kHz - 1,000kHz
- Test duration
- T = 0:01min - 99:59min
T > 99:59min --> endless - Outputs
- Direct
- Via 50ohm coaxial connector
- Coupling mode
- L, N, PE; all combinations
- DUT supply
- AC: 300V/16A; 50/60Hz
DC: 300V/10A - CRO trigger
- 5V trigger signal for oscilloscope
- Test Routines
- Quick Start
- On-line adjustable parameters, easy-to-use
- Standard Test routines
- As per IEC 61000-4-4, Levels 1 - 4
As per EN 61000-6-1, -6-2
Manual Standard Test routine - User Test routines
- Synchronous burst release, Random burst release, Change voltage after T, Frequency sweep within one burst, Frequency sweep with constant, number of pulses, Frequency sweep with constant burst duration Change polarity afte
- General Data:
- Interfaces
- Serial interface
- USB
- Parallel interface
- IEEE 488, addresses 1 - 30
- Analog output
- 0 - 10VDC to control an external transformer
- CN interface
- 15pin SubD connector to control an external coupling network
- Fail inputs
- DUT monitoring via Fail1 and Fail2 input (one each)
- Dimensions
- Dimensions
- 19 Inches, 3HU
- Weight
- approx. 25kg
- Mains
- Supply voltage
- 115V/230VAC +10%/-15%
- Power
- approx. 75W
- Frequency
- 50/60Hz
- Fuses
- 2 x T 2AT (230V) or 2 x T 4AT (115V)
- Safety
- Safety standard
- EN/IEC 61010
- Security circuit
- Control input (24VDC)
- Warning lamp
- Floating contact (max. 230V/6A)