Compliant Standards & Overview
Teseq HV-AN 150, SME HV-AN 150, & EXT 10uF
This video provides an overview of the Teseq HV-AN 150 LISN/AN including jumper modifications for compliance to a variety of different 5uH requirements.
System Overview
Overview
Teseq’s artificial network HV-AN 150 is the first universal solution which covers several applications and standards in the Automotive, Airborne and MIL range. It offers the right solution for both high current and high voltage EUTs and can be housed for having a shielded box as proposed in the draft versions of CISPR 12, CISPR 25 and ISO 7637-4.
Specifications
Common Standards |
LV: CISPR 25, ISO 11452-4 HV: CISPR 12, CISPR 25, ISO/DTS 7637-4 |
Frequency range |
100 kHz to 100 MHz (max. 200 MHz) |
Inductance - Adjustable |
5 µH || 47.6 Ω ± 20% (magnitude) 5 µH || 50 Ω ± 10% (magnitude) 5 µH || 49.5 Ω ± 20% (magnitude) 5 µH + 1 Ω || 47.6 Ω ± 20% (magnitude) ± 11.5 deg (phase) 5 µH || 49.5 Ω ± 20% (magnitude) 100 kHz to 150 MHz, |
AC max. voltage: |
500 V |
DC max. voltage: |
1000 V |
Current max.: |
150 A, 60 min (Unit Dependent some 200Amps) |
Test voltage: |
1500 VDC, 2 s |