Teseq NSG 4070D

Rent 100 Watt Immunity Test System
In Stock - Order by 3 p.m. ships today
  • Built-in 100 Watts 150 kHz to 230 MHz Amplifier 
  • 1 GHz Signal Generator & 3 Power Meter Inputs
  • Model: NSG 4070D-A230M-100
  • Includes Laptop with icd.control Software
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Power Cable
  • Printed Manual & Calibration Documentation
  • Pasternak PE 7021-6 6dB & 20dB Attenuator 
  • N Female, N Male, BNC, Adapters (3)
  • 50 Ohm Termination Load
  • 9 Pin D Shaped Serial Cable
  • N to N Cable LE 239 & 12inch
  • Silver U Shaped Jumper
  • BNC to BNC Cable
  • USB Stick with Software
  • Ethernet Cable
  • USO USB Box & 10m. Cable
  • N to BNC Cable
  • USB Cable
  • Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The NSG4070D by Teseq (Ametek CTS) is a compact and versatile EMC immunity test system, featuring an integrated signal generator, power amplifiers, and RF power meter. It provides precise and efficient electromagnetic susceptibility testing for a wide range of applications, including industrial, automotive, medical, and consumer electronics.

The heart of the NSG 4070Dis its integrated signal generator, producing sinusoidal signals from 4kHzto1GHz,withlevelsfrom-60dBm to+10dBm.Itincludes an internal modulator for amplitude and pulse modulation (AM and PM), both adjustable within and beyond standard specifications.

The NSG4070D includes a modular power amplifier system tailored to specific testing needs:

      Testing in the frequency range from 150 kHzto230MHz (e.g.,IEC 61000-4-6 and ISO 7367-4 pulse A) with power models of 50 Wand 100 W.

      Testing in the frequency range from 4 kHzto400MHz (e.g., ISO11452-4, MIL 461CS114) with 50 W and 100 W models.

During the testing, the Equipment Under Test (EUT) can be monitored in different ways. This monitoring can be logged in the result file and can be used to abort the test. The NSG 4070D offers multiple monitoring options for:

      TTLInputs/Outputs: For seamless integration with external monitoring equipment.

      Optical Monitoring: Detects the status of light indicator for real-time feedback.

      Digital and Analog monitoring: For up detecting the input voltage as high as 24V

The NSG 4070 offers pre-programmed test routines for easy setup, enabling quick selection of standard tests. Users can modify and save custom routines, eliminating the need to create them from scratch.

The NSG4070's vector programming mode enables precise control of frequency and level parameters for each test vector, with adjustable start and stop conditions for complex test

Specifications RF Generator:
Frequency Range
4 kHz to 1 GHz
Resolution
1 Hz
Reference frequency
10 MHz
Aging
25 ppm
Specifications RF Level:
Level range
Negative 60 dBm to 10dBm
Resolution
0.1 dB
Settling time
10 ms
Specifications AM:
Modulation depth
0 to 100 %
Modulation frequency range
1 Hz to 50kHz
Frequency resolution
1 Hz
Pulse Modulation:
Rise/fall time (10%/90%)
Less than 1 us
Modulation frequency range
0.01 Hz to 1 MHz
Frequency resolution
10 mHz
Duty cycle
1% to 100%
Pulse width
Less than 1 us/ 180 Degrees
External Modulation:
Delay time
Less than 1 us/ 180 Degrees
Period
min. 20 us
Pulse width
min. 10 us
RF Power Meter:
Frequency range
Channel 1
Negative 35 dBm to positive 27dBm
Channel 2 &3
Negative 45 dBm to positive 20dBm
Accuracy 10 to 30 degrees C
Typically less than 0.3 dB
Max. input
+28 dBm
Noise level
Less than 5 dB below measurement range
Connector
BNCsocket, 50 Ohms