Teseq ProfLine 2105 - Front Includes Desktop
Teseq ProfLine 2105 - Front
Teseq ProFline Power Supply - Front
Teseq CCN 1000-1 Front

Teseq ProfLine 2105

5 kVA Harmonics & Flicker Test System
  • Designed for Flicker & Harmonics Testing
  • Complete Test System for IEC 61000-3-2 and 3-3
  • Max Single Phase EUT 300 Volts 16 Amps
  • Built-in Simulated Flicker Impedance
  • Current ISO 17025 Accredited Calibration
Available Options

Included Accessories

  • NSG 1007 & CCN 1000-1
  • Power Cables (3) & USB Cable 
  • 4 Prong Power Cable for NSG 1007
  • DB-37/68 PIN HD - PC to CCN Cable
  • DB-9 Series Cable
  • Metal Terminal block Covers
  • Cable Brackets (2)
  • Red & Blue Cables & Connectors (2)
  • 240V EU to US lug (Installed)
  • 240V EU Power Plug
  • Quick Install & California Instruments Document
  • Dell Computer, Keyboard, Monitor & Mouse
  • Monitor Stand (2)
  • Display Port Cable & USB Cable 
  • Red Shipping Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description 

ProfLine 2105 is an accurate and flexible 1-phase system designed to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. The system is supplied complete with a stable, accurate, programmable 5 kVA power source. The ProfLine 2105 system is therefore ready to measure and record any harmonics and flicker created by the EUT. A wide range of AC source systems are available from Teseq, please see ProfLine 2103, 2115, 2130, 2145 datasheets for suitable systems at different power levels or for 3-phase operation.

 Measurements are made using precision, no burden, active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fi tted inside a PC. One voltage and three current measuring channels are used to make simultaneous measurement of both current and voltage. Calculations are made using dedicated Teseq software (WIN 2100) to determine harmonics (classes A-D), inter-harmonics, fl icker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.

Impedance

Measurement of fl icker requires a fi xed, stable source impedance as specifi ed in IEC 61000-3-3 (0.24 Ω + j0.15 Ω in the line and 0.16 Ω + j0.1 Ω in the neutral). The precision power source (NSG 1007-5) supplied as part of the system is able to accurately simulate this impedance by careful control of the relationship between voltage and current. This eliminates the need for a costly physical impedance. However, physical lumped impedances are available from Teseq, see options list.

Power quality measurement

 The power source (NSG 1007-5) supplied as part of the ProfLine 2105 system is able to perform tests in conformance to a number of immunity standards. IEC 61000-4-13 (immunity to harmonics and interharmonics), IEC 61000-4-14 (voltage fluctuations), IEC 61000-4-17 (ripple on DC) and IEC 61000-4-28 (variation of power frequency). Additionally it can also perform pre-compliance testing to IEC 61000-4-29 (voltage dips, interrupts and variations on DC supply) and IEC 61000-4-11. With the addition of further options IEC 61000-4-8 (power frequency magnetics) and fully compliant IEC 61000-4-11 (voltage dips, interrupts and variation on AC supply) can be implemented.

Specifications
Power Source
5kVA single phase 0-270V, 18.5A
Synthesized impedance
Per IEC 725
Data Acquisition
4 channels
Sampling Rate
>200kHz (4000 times fundamental) per channel
Harmonics Analysis
Range
Fundamental to 40th harmonic
Fundamental
0.05% +/- FS +/-0.05% / kHz
Harmonics
0.1%+/- 0.1% +/-/ kHz
Measurement Window
Real time FFT of 200msec.
Smoothing
1.5 sec.
Flicker Analysis
Range
0.4- 5 Pst
Accuracy
3%
Resolution
0.01
Integration Time
10 mins
Plt
0.4 - 5
dmax
0.1 - 100%
dc
0.1 - 100%
dt
0.1 100%
dt over 3.3%
10 - 5000 ms
Other Immunity Testing
IEC 61000-4-11
AC voltage dips, interrupts and variations with optional EOS1
IEC 61000-4-13
Immunity to harmonics and interharmonics
IEC 61000-4-14
Immunity to voltage fluctuations
IEC 61000-4-17
Ripple on DC input power ports
Weight
5 kg, 11 pounds
Dimensions
9x43x56 cm, 3.5x17x22 inches
NSG 1007-5 Power Supply
Supply Option
208 or 400
Operating Modes�
AC, DC, or AC + DC
Frequency Range
16Hz-1000Hz
Total Power
5kVA
Load Power Factor
0-1 at full rated power
Output noise
(20 kHz to 1 MHz) <250 mVrms typical, <500 mVrms maximum
Harmonic distortion
�<1% from 16-66 Hz, <2% at 400 Hz, <3% at 800 Hz
DC offset
<20 mV
External amplitude modulation
Depth 0-10%, Frequency DC-2 kHz
Isolation voltage
300 Vrms output to chassis
AC mode current
Low range Steady state
37
Low range Peak repetitive
110
High range steady state
18.5
High range peak repetive
96
DC mode�
Supply option
208
Maximum power
3,500 Watts
Output noise
(20 kHz to 1 MHz) <250 mVrms typical, <500 mVrms Max
Line regulation
<0.1% FS for 10% Line change
Related Videos
EM Test DPA 500N Overview