Description
Additionally, the NetWave series (1-phase) offers the necessary capabilities for avionics testing as per DO-160, Airbus ABD0100 and Boeing as well as per MIL-STD-704. Data SheetUser Manual
Specifications
Model : NetWave 7.3 |
Multifunctional AC/DC source, 7,500 VA AC / 9,000 W DC, with built-in isolation transformer required to perform tests as per aircraft (DO-160, Airbus and Boeing) and military (MIL-STD-704) standards |
Output voltage |
0 V - 360 VAC (RMS) 0 V - +/-500 VDC |
Output current * |
26 A (RMS) continuous 47 A (RMS) short-term (max. 3 s) 200 A repetitive peak *(@max. 300 VAC, 360 VDC) |
SourceAC mode |
Extended trigger functions |
Segment "Step |
Ramping of voltage and/or frequency in constant time windows |
Specifications |
|
Number of Lines |
1 |
Output Voltage AC (V) (p-n) |
360 |
Output Voltage DC (V) |
500 |
Output Power AC (kVA) |
7.5 |
Output Power DC (kW) |
9 |
Output Current continuous (A) 1) |
26 |
Output Current short term (max. 3s) (A) 1) |
47 |
Ouput Current repetitive peak (A) 1) |
200 |
Bandwidth (kHz) |
5 |
Output frequency |
DC - 5,000 Hz |
Frequency accuracy |
100 ppm |
DC offset with AC signal |
<20 mV with linear load |
Phase accuracy |
Resolution 1° |
Output noise |
< 50 V : 110 mV rms > 50 V : 320 mV rms + 0.02% of set value |
Slew rate |
8 V/us |
Regulation |
|
Voltage sense |
Internal or external, 4 wires |
Distortion (THD) |
Less than 0.5 %, @50/60 Hz |
Output voltage stability |
Better than 0.1 % |
Output voltage accuracy |
Better than 0.5 % |
Max. compensable drop on wire |
5 % of V nominal. |
Current limiter f<75 Hz |
2 A to Imax for (NetWave 3) 5 A to Imax for (NetWave 7.x) Stop / Current limiter |
Trigger & Monitoring |
|
Trigger |
2 inputs, 2 outputs |
DUT monitors |
2 inputs, configurable |
Waveform Generator |
|
Segment types DC |
DC, Ramp, Square, Triangle, Sawtooth, Step, Sine, Sine sweep, Sine ramp, Damped sinewave, Sine ripple, Profile, Square sweep, Noise, Sine Dwell, Sinc, Harmonic, Exponent .. |
Segment types AC |
Sine, Modulation, Sine sweep, Sweep on Sine, Sine up/down, Overswing, Sine offset, Sine Dip, Sine switching, Harmonic, Interharmonic, Interharmonic step, Harmonic distortion ... |
Segment duration |
Unlimited |
Standards
Below is a list of common standards for Harmonics & Flicker Tester:
- AIRBUS
- BOEING
- DO 160 Section 16
- EN 61000-3-11
- EN 61000-3-12
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-4-11
- EN 61000-4-13
- EN 61000-4-14
- EN 61000-4-17
- EN 61000-4-28
- EN 61000-4-29
- IEC 61000-3-11
- IEC 61000-3-12 Ed.2:2011
- IEC 61000-3-2
- IEC 61000-3-3
- IEC 61000-4-11
- IEC 61000-4-13
- IEC 61000-4-14
- IEC 61000-4-17