Solar 7054-1
Related Equipment
Description
The peak amplitude of the Solar Model 7054-1 is adjustable from 10 V to over 600 V into 5 Ω. The source impedance is less than 0.5 Ω. The transient shape approximates the curve given in Figure 19 of MIL-STD-462 with less than or equal to 2.0 µS rise time and approximately 10 µS fall time.
On 50, 60 or 400 Hz power lines the transient can be applied in a periodic manner to the negative or the positive half-cycle of the power frequency. The transient's relation to the sine wave may be adjusted in phase from 0° to 360°. For nonsynchronous injection on either AC or DC lines, the repetition rate can be adjusted from 0.8 pulse per second to 10 pulse per second. Single transients can be applied with the pushbutton on the panel.
Two sets of output terminals allow either parallel or series injection into the power line. Series injection may be used on DC and AC lines. Parallel injection is used on DC lines only. The output winding used for series injection can carry 25 A of power current. The output terminals are isolated from the chassis and the power cord.
- Spike amplitude:
- Continuously adjustable from less than 10 V to more than 250 V peak
- Repetition rate:
- Continuously adjustable from 0.8 to 10 pulse per second
- Rise time:
- Less than or equal to 2.0 uS into 5 Ohm resistive load
- Spike duration:
- Output falls to zero in approximately 10 uS
- Spike shape:
- See Figure 3. Similar to Figure 19 of MIL-STD-462
- Phase adjustment:
- Spike position adjustable from 0 to 360 degrees periodically on 50, 60 or 400 Hz sine wave
- Internal impedance:
- Less than 0.5 Ohms
- Output power:
- More than 300 kW peak into 0.5 Ohm load
- Power current in series injection mode:
- Handles up to 25 A of current at power frequencies
- Power requirements:
- 115 V 60 Hz, 1.6 A (230 V 50 Hz, 0.8 A available)
- Dimensions, standard rack panel:
- 19" wide x 7" high x 12.75" deep (48.26 cm x 17.78 cm x 32.38 cm)