Description
Transient Immunity Generator:
- Switch - Power supply (100A/200A) & Signal/Data lines (2A)
- Laptop & ISO 17025 Calibration Included
- Pulses E10 and E13 of the LV 124/LV 148 standard
- Bidirectional Current Direction & Rise/fall time less than 200ns
- Free Technical Support & 2 Days Free Transit
- Separate Switch In Ground Line
- Turnkey Solution - Arrives Ready for Testing!
Overview
As per FORD FMC1278 and EMC-CS-2009.1 a part of the test pulses is not generated using a transient pulse generator similar to the ones defined as per ISO 7637 but being based on a circuitry including a Potter & Brumfield 12VAC relay and specifically defined components such as inductors, capacitors, resistors and switches with the aim of simulating "real-world transients".
The EM TEST RCB 200N1 transient generator meets the requirements set out by the FORD FMC1278 and EMC-CS-2009.1 standard document. It is built using the components outlined in Figure F-1 to generate pulses such as CI 220 A1, A2-1, A2-2, C-1 and C-2, CI 260 F and RI 130 A2-1 and A2-2 for which the RCB 200N1 is built into a metal housing. For RI 130 testing the RCB 200N1 offers BNC-type coaxial outputs to connect the specified test fixture needed for this particular test.
Data SheetUser ManualSpecifications
Common Standards |
FORD FMC1278 & EMC-CS-2009.1 Jaguar EMC-CS-2010JLR V1.1 (2011-01) & JLR-EMC-CS V1.0 Amd 4 |
TECHNICAL DATA |
|
RCB 200N1 |
Circuitry as per Annex F, Figure F-1 with the following components: |
Resistor R1 |
51 ohms, 25W |
Resistor R2 |
220 ohms ± 5%, 2W |
Resistor R3 |
33 ohms ± 5%, 10W |
Resistor R4 |
6 ohms ± 5%, 50W |
Capacitor C1 |
100 nF capacitor, 400V |
Inductor L1 |
To select the test |
Inductor L2 |
|
Diode D1 |
Activates the DUT supply for CI 220 and CI 260 test pulses; no function for RI 130 as this is performed without DC voltage |
Transistor Q1 |
To select the test |
SW0 - SW4 |
Activates the DUT supply for CI 220 and CI 260 test pulses; no function for RI 130 as this is performed without DC voltage |
RLY1 |
To select the test |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards
- Ford EMC-CS-2009.1
- Ford FMC1278
- Jaguar EMC-CS-2010JLR V1.1 (2011-01)
- Jaguar JLR-EMC-CS V1.0 Amd 4