- Serial interface
- 2 x USB A for memory stick,
1 x USB B for service only,
Opto - Link to USB for remote
- Lan
- Ethernet for remote
- Analog output
- 0 - 10 VDC to control an external transformer
- Sys.link
- 26 pin high density connector to control an external coupling network
- Fail inputs
- EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2
- Ext. Trigger
- BNC Ext. Trigger IN pos slope 5 V
- Ext. Sync Input
- Differential input,
50 V - 690 VAC,
2 x 4 mm MC Safety connectors
- 16 A models
- 19"/3 HU, 500 mm deep, approx. 21.8 kg
- 32 A models
- 19"/6 HU, 500 mm deep, approx. 40 kg
- Temperature
- 10 C to 35 C
- Humidity
- 30 % to 75 %, non condensing
- Atmospheric pressure
- 86 kPa (860 mbar) to 106 kPa (1,060 mbar)
- Supply voltage
- 85 V - 264 V
- Frequency
- 50/60 Hz
- Power
- approx. 75 W
- Fuses
- 115 V: 2 x 4 A slow blow, 230 V: 2 x 2 A slow blow
- Safety standard
- IEC/EN 61010
- Security circuit
- Control input (24 VDC)
- Warning lamp
- Floating contact (max. 60 V/2 A)
- Mains supply
- Plug depends on the country of use
- EUT supply
- Plug depends on the country of use
- EUT adapter
- Socket depends on the country of use
- Burst Module
- As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2
- Test voltage
- 200 V - 5,500 V +/- 10%; 100 V - 2,750 V +/- 10% into 50 ohm
- Pulse shape
- 5/50 ns into 50 ohm and 1,000 ohm
- Rise time tr
- 5 ns +/-30% into 50 ohm;
5 ns+/ 30% into 1,000 ohm
- Pulse width td
- 50 ns +/-30% into 50 ohm;
50 ns -15/+100 ns into 1,000 ohm
- Source impedance
- 50 ohm
- Polarity
- Positive/negative
- Trigger of bursts
- Automatic, manual, external
- Synchronization
- 0 - 360 Degree, resolution 1 Degree (16 - 500 Hz)
- Burst duration (td)
- td = 0.10 ms - 9,999 ms
- Repetition rate (tr)
- tr = 10 ms - 9,999 ms
- Spike frequency
- f = 1 Hz - 1,000 kHz
- Test duration
- T = 0:01 min - 99:59 min
T > 99:59 min --> endless
- Direct
- Via 50 ohm coaxial connector
- Coupling mode
- L, N, PE; all combinations
- EUT supply
- AC: 300 V / 400 V, 50/60 Hz
DC: 300 V / 400 V,
Current: 16 A / 32 A
- CRO trigger
- 5 V trigger signal for oscilloscope
- Quick Start
- On-line adjustable parameters, easy-to-use
- Standard Test routines
- As per IEC/EN 61000-4-4, Levels 1 - 4
As per IEC/EN 61000-6-1, -6-2
As per ECE R-10 Rev5
- Extended Test routines
- Change voltage after T,
Frequency sweep within one burst,
Frequency sweep with constant number of pulses,
Frequency sweep with constant burst duration,
Synchronous burst release,
Random burst release
- Surge Module
- As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2
- Voltage (o.c.)
- 160 V - 5,000 V +/- 10%
- Pulse front time
- 1.2 us +/- 30%
- Pulse duration
- 50 us +/- 20%
- Current (s.c.)
- Max. 2,500 A +/- 10%
- Pulse front time
- 8 us +/- 20%
- Pulse duration
- 20 us +/- 20%
- Polarity
- Positive/negative/alternating
- Release of pulses
- Automatic, manual, external
- Synchronization
- 0 - 360 degrees, resolution 1 degree
- Repetition rate
- max. 1 Hz (1 s - 9,999 s)
- Event counter
- 1 - 99,999, selectable
- Direct
- Via HV connectors for external coupling networks
- Coupling mode
- Line to line
Line(s) to ground
- EUT supply
- AC: 300 V / 400 V,
50/60 Hz DC: 300 V / 400 V,
Current: 16 A / 32 A
- CRO trigger
- 5 V trigger signal for oscilloscope
- CRO U-monitor
- 10 Vp at 5,000 V
- CRO I-monitor
- 10 Vp at 2,500 A
- Peak voltage
- 5,000 V in the touch display
- Peak current
- 2,500 A in the touch display
- Overcurrent protection
- Breaks the Surge test when the surge current is over the limit,
Limiter for differential mode,
Limiter for common mode
- EUT current
- RMS current, Range 50 A, < +/-5%
- EUT overcurrent protection
- Breaks the test when the EUT current is over the limit,
- Quick Start
- One-line adjustable parameters, easy-to-use
- Standard Test routines
- As per IEC/EN 61000-4-5,
As per IEC/EN 61000-6-1,
As per IEC/EN 61000-6-2,
Manual Standard Test routine
- Extended Test routines
- Voltage iteration after n pulses,
Angle iteration stepwise,
Phase angle random iteration,
Change coupling after n pulses,
Change phase angle after n pulses
- Pulsed Magnetic Field
- as per IEC/EN 61000-4-9
Test levels 100, 300 and 1,000A/m
Test level continuously adjustable under Quick Start
- As per
- IEC/EN 61000-4-11,
IEC/EN 61000-4-29
and IEC/EN 61000-6-1, -6-2
- Channel PF1/PF2
- AC voltage: max. 300 V / 400 V
AC current: max. 16 A / 32 A
DC voltage: max. 300 V / 400 V
DC current: max. 16 A / 32 A
- Frequency
- 16 Hz - 500 Hz and DC
- Switching time
- > 1 us < 5 us into a 100 ohm resistive load (SVP 100)
- Inrush current
- > 500 A
- Protection
- Both channels are protected against short-circuit conditions.
- Trigger of events
- Automatic, manual, external
- Synchronization
- 0 - 360 degrees, resolution 1 degree (16 - 500 Hz)
- Repetition rate
- 10 ms - 9,999 s
- Event duration
- 10 us - 99.999 s
- Event counter
- 1 - 99,999, selectable
- EUT terminals
- L, N and PE
- CRO trigger
- 5 V trigger signal for oscilloscope
- EUT voltage (rms)
- In the touch screen
- EUT current (rms)
- In the touch screen
- MON V
- Measurement of the EUT voltage, built-in divider:
300 V: 42,5:1, 10 V =425 Vpk,
400 V: 56.6:1, 10 V =566 Vpk
- MON I
- Measurement of the EUT current,
16 A: 7 A/V; 10 V =70 Apk,
32 A: 10 A/V; 10 V =100 Apk
- Quick Start
- On-line adjustable parameters, easy-to-use
- Standard Test routines
- As per IEC/EN 61000-4-11 for AC supplies
As per IEC/EN 61000-4-29 for DC supplies
As per EN 61000-6-1, -6-2 Manual Standard Test routine
- Extended Test routines
- Voltage variation, control of an external variac,
Phase angle iteration, Reduced time iteration,
Angle inverse mode, Random by step and list Inverse mode
- 50/60 Hz magnetic field
- As per IEC/EN 61000-4-8 Test levels 1, 3, 10 and 30 A/m with external current transformer MC 2630, Test levels 100, 300 and 1,000 A/m with external current transformer MC 26100