Ask Us About: Burst/EFT Surge EMC Test Equipment Rental

Filters

Burst/EFT Surge EMC Test Equipment Rental

Rent combination wave surge and electrical fast transient EFT generators designed for compliance to IEC 61000-4-4 and IEC 61000-4-5 test requirements. These systems are typically broken down by the 4kV surge and 6kV surge test levels, with the higher voltage systems providing capabilities for 100kHz ringwave as well.

Given the modularity of generators in the market, systems can be configured as a stand alone EFT system (as with the EM Test UCS 500N5E), or integrated with a variety of different capabilities. This typically includes a standard single phase built-in CDN designed for both AC and DC power up to 16amps. However, when renting these variety of EMI test systems, it is important to ensure system meets all required pulse capabilities in advance.


Coupling decoupling networks (CDNs) are the devices used to couple pulses onto different types lines (AC, DC, Data, etc.). Capacitive coupling clamps are designed to couple EFT onto data lines at prescribed lengths in accordance with IEC 61000-4-4. At lower DUT/EUT current and voltage levels (typically less than 32 amps 3-phase power) the CDNs will have capabilities for coupling both EFT and Surge pulses. This is also true for the newer three phase CDNs automatic couplers where the equipment adjusts to the associated EUT current level automatically.

When conducting testing for compliant surges to IEC 61000-4-5 it is recommended to use the correct corresponding coupler with the associated generator (same manufacturer etc.) This helps to ensure communication and line synchronization between the the coupler and transient generator allowing for pulses to be applied at the correct degree. 


Pulse verification for surge is done by monitoring both voltage and current waveforms. This is accomplished by the use of a current monitoring probe (Pearson 110) that has capabilities measure the fast pulse and a high voltage differntial probe for the voltage waveform. EFT is typically monitored with an EFT verification kit, which can be measured both from the direct out and after the capacitive coupling clamp (if used). 

These are often seen done prior to testing to verify that the generator is indeed providing the correct associated pulse within specifications. It is highly recommended when possible to ensure accurate test results that this be done.


Showing 17 - 32 of 34 products
View
Haefely FP-COMB 32 Front Side Haefely FP-COMB 32 Front
Haefely FP-COMB 32 - Rent 3-Phase 480 Volt 32 Amp CDN
  • Coupler for Surge, EFT, & Ringwave Pulses
  • Maximum 480 Volts 32 Amps AC/DC
  • Automatic Coupler for Axos5/8 Systems
Price Match Guarantee
Teseq CDN 3425 Front Side Teseq CDN 3425 Side Top
Teseq CDN 3425 - Capacitive Coupling Clamp Rental
  • Complies with IEC 61000-4-4 Ed 2 & 3
  • Maximum Burst Voltage 8 kV
  • Used for Test EFT/Burst on Data Lines
CDN 2000-06-25 - Side CDN 2000-06-25 - Front
EMC Partner CDN 2000-06-25 - Rent 3-Phase 25 Amp CDN
  • Coupler for Damped Oscillatory Pulses
  • Maximum 480 Volts 25 Amps AC
  • Rented with MIG-OS-OS1 Generator
Teseq NSG 3060 CDN 3061 Front Top Teseq NSG 3060 CDN 3061 Front Side
Teseq NSG 3060 CDN 3061 - Rent 6kV Transient Test System
  • 6.6kV Surge & Ringwave, 4.8kV EFT Generator
  • Typically used for Single Phase EUT 
  • Includes Teseq CDN 3061 (270V/16Amps)  
Sale price Buy Used - $29,000
Teseq CDN HSS-2 Front Side Teseq CDN HSS-2 Side
Teseq CDN HSS-2 - Rent Symmetrical High-Speed Data CDN
  • CDN for up to 8 wire unshielded twisted pair (UTP)
  • Max Surge Voltage 2 kV Current 50 Amps
  • Coupling to 1, 2 or 4 pairs
Teseq CDN 3083-S100 - Front Side Teseq CDN 3083-S100 - Side Above
Teseq CDN 3083-S100 - Rent 3-Phase 100 Amp Surge CDN
  • Coupler for Surge to IEC 61000-4-5
  • Max 100 Amps 690 V AC or 620 V DC
  • Manual Coupler for NSG 3060 or NSG 3040
Sale price Buy Used - $17,000
ISO 17025 Calibrated
Teseq CDN 3083-B100 - Front Side Teseq CDN 3083-B100 - Side Top
Teseq CDN 3083-B100 - Rent 100 Amp 3-Phase Burst CDN
  • Designed for Burst to IEC 61000-4-4
  • Max 100 Amps 690 V AC or 1,000 V DC
  • Handles up to 8.8 kV EFT/Burst Pulses
ISO 17025 Calibrated
Teseq CDN 3063 - Front Side Teseq CDN 3063 - Rent 3-Phase 480 Volt 32 Amp CDN
Teseq CDN 3063 - Rent 3-Phase 480 Volt 32 Amp CDN
  • Coupler for Surge, EFT, & Ringwave Pulses
  • Maximum 480 Volts 32 Amps AC/DC
  • Automatic Coupler for NSG 3060/NSG 3040
Sale price Buy Used - $11,000
ISO 17025 Calibrated
Teseq CDN 3061 - Front Top Teseq CDN 3061 - Front
Teseq CDN 3061 - Rent Single-Phase 16 Amp CDN
  • Coupler for Surge, EFT, & Ringwave Pulses
  • Maximum 270 Volts 16 Amps AC/DC
  • Rented with Teseq NSG 3060 Test System
EM Test CNV 504N1.3 - Front Side EM Test CNV 504N1.3 - Front
EM Test CNV 504N1.3 - Rent Unsymmetrical Unshielded CDN
  • CDN for 4 Unshielded Unsymmetrical Lines
  • Coupler for Surge & Ringwave Transients
  • Maximum Impulse Voltage 4 kV
Rent Haefely IP4B - Front Side Rent Haefely IP4B - Front Top
Rent Haefely IP4B Capacitive Coupling Clamp
  • Construction as per IEC 61000-4-4 Ed.3
  • EFT/Burst testing of signal and data lines
  • For cable diameter from 4 – 40 mm
Thermo Keytek CCL Front Side Thermo Keytek CCL Side
Thermo Keytek CCL - Capacitive Coupling Clamp Rental
  • Designed for EFT Testing Data I/O Lines
  • Includes Plastic Safety Cover
  • Used with the EMC Pro Plus Generator
EM Test NX5 Front Side EM Test NX5 Front
EM Test NX5 bsp-1-400-16 - Rent Transient Generator 400V CDN
  • Configuration: 5 kV Surge, 5.5 kV Burst, & Power Fail
  • Built-in single phase CDN Max 400 V/16 A AC or DC
  • Laptop with iec.control software included
Price Match Guarantee
EMC Partner IMU-MGS - Front Side EMC Partner IMU-MGS - Front
EMC Partner IMU-MGS - Rent 4 kV Surge & EFT Generator
  • 4.1 kV Surge & 4.4 kV EFT/Burst Generator 
  • Built-in CDN Max 300 Volts 16 Amps AC & DC
  • Model: IMU-MGS F4-S4-P
ISO 17025 Calibrated
EMC Partner CN-EFT100 - Front Side EMC Partner CN-EFT100 - Side Above
EMC Partner CN-EFT1000 - Rental Capacitive Coupling Clamp
  • IEC 61000-4-4 & IEC 61000-4-18 Compliant
  • Designed for Coupling to I/O Lines  
  • Useable for Damped Oscillatory Wave Testing
EM Test PCD 8 S-3-690-1000-100 Front Side EM Test PCD 8 S-3-690-1000-100 Side
EM Test PCD 8 S-3-690-1000-100 - Rent 100Amp Manual Surge CDN
  • Coupler for Surge to IEC 61000-4-5
  • Max 100 Amps 690 V AC or 1,000 V DC
  • Manual Coupler for NX5/NX7 Systems
ISO 17025 Calibrated

34 products

Recently viewed