Haefely AXOS 8 - Rent 7 kV Surge, EFT, & Ringwave Generator

Haefely 7kV Transient Generator:

  • 7kV Surge & Ringwave, 5.5 kV EFT/Burst
  • Built-in CDN: 264 V/16 Amps AC & 220V /10 Amps DC
  • Compliant to ANSI Coupling Requirements 
  • Front Panel Voltage & Current Monitoring Ports
  • External 3-Phase CDNs Available

Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Equipment

AXOS8 Video Guides

AXOS8 System Overview

This video on the Haefely 7kV transient test system includes introduction, setup instructions, and modifications of testing parameters all done through the front panel interface of the system.

Haefely AXOS Platform Overview

This video provided by Haefely, the manufacturer of the AXOS5 and AXOS8 test system, provides system information about connections both through the front and back of the test system.

Data SheetUser Manual

Overview

Welcome to the unique design and concept of modularity designed by HAEFELY.

HAEFELY is recognizing an increasing interest in testing departments to configure the required functions in compact immunity test systems more flexible than ever. For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future.

Moreover, constantly reduced product development times call for powerful, easy-to- operate and ready-touse conducted immunity test systems which can be expanded in a multitude of different test applications. Customer requirements, particularly in the telecommunications and industrial electronics sector, emphasize a test system‘s accuracy and modularity, thus clearly pointing to easy to expand T&M equipment that is favourably priced and suitable for most of industries.

The new AXOS series has been tailored to exactly meet these requirements, offering special cost advantages for T&M applications in the development, production and servicing of telecommunications, components as well as safety and industrial electronics.

All AXOS test systems come equipped with all the hardware needed for instant upgrades by only entering optional key codes into the licence code manager of the unit. After entering the key code(s) the additional test functionalities like Surge Combination Wave, Ring Wave, Telecom Wave, EFT/Burst or Voltage Dips and Interrupts become available immediately. No direct intervention has to be done by the user at all. 

Specifications

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12

 (Optional: EN/IEC 61000-4-11 & EN IEC 61000-4-29)

General Data

 

Control Power

85V – 264V, 50/60 Hz

External Trigger Input

5 VTTL

Trigger Output

5 VTTL


Sync Input

BNC 10 V – 264 V AC

Dimensions

45 x 18 x 49cm, 17.11 x 7.02 x 19.29 inches

Weight

25kg, 55 lbs

IEC/EN 61000-4-4 Burst/EFT

 

Output Voltage

0.2 – 5.0 kV ±10%

Output Impedance

50 Ohms

Rise Time

5 ns ± 30%

Impluse Duration

50 ns ±30% at 50 ohms, 50 ns – 15 + 100 ns at 1,000 Ohm

Spike Frequency

1 Hz – 1 MHz

Burst Duration

10 µs – 1 s

Burst Period

1 ms – 10 s

Test Time

1 s – 1,000 minutes

Integrated single phase coupling/decoupling network

264 V AC/16 A

220 V DC/10 A

IEC/EN 61000-4-5 Surge Waveform

 

Max  Voltage

0.2 – 7.0 kV ± 10%

Voltage Rise Time

1.2 µs ± 30%

Voltage Duration

50 µs ± 20%

Output Impedance

2 Ohms

Phase Sync

0 - 359°with 1° steps or asynchronous mode

Output Current

0.1 – 2.5 kA ±10%

Current Rise Time

8 µs ± 20%

Current Duration

20 µs ± 20%

Integrated single phase CDN

264 V AC/16 A, 220 V DC/10 A

IEC/EN 61000-4-11 Dips & Interrupts

Also IEC / EN 61000-4-29

Max  Voltage

264V AC/DC

Max Current

16 A AC/DC continuous, 40 A for 3 seconds

Interupt Dip Level

0%, 0% - 99% with external voltage source

Interrupt Time

.5 period – 800 periods, 100 µs – 1000 minutes

Interval Time

1 period – 800 periods, 100 µs – 1000 minutes - asynch

Test Time

1 s – 1000 minutes

Phase Sync

0-359 degress 16/40/50/60 Hz

RMS Voltage and Current Monitor

BNC output 100:1V – 10A/V

IEC/EN 61000-4-12 Ed. 2 Ring Wave

 

Max  Voltage

0.2 – 7.0 kV ± 10%

Frequency

100 kHz

Rise Time 

OC 5 µs; SC 1 µs

Impedance

12 Ohm, 30 Ohm

Phase Sync Accuracy

± 1 degree

Repetition Rate

Up to 30 pulses / min