EM Test OCS 500N6.1 - Rent Slow Oscillatory Wave Generator

Availability:
In Stock - Order By 3PM Ships Today!

EM Test Oscillatory Wave Simulator:

  • 100 kHz & 1 MHz 3kV Waveform Generator
  • Compliant to ANSI C37.90 & IEC 61000-4-18
  • Built-in 1-Phase CDN 250V/16A AC & DC
  • Antenna for IEC 61000-4-10 Available
  • Laptop & ISO 17025 Calibration Included

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Damped Oscillatory Waveform Equipment

Description

Overview

The OCS 500N6 includes test capabilities for ringwave up to 6kV (as per EN/IEC 61000-4-12) and the damped oscillatory waves at 100 kHz and 1 MHz up to 3 kV (as per EN/IEC 61000-4-18).

The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations.

The OCS 500N6 can also be used to perform magnetic field tests as required in EN/IEC 61000-4-10 using a magnetic field coil such as the MS 100N.

Data Sheet User Manual

Specifications

Common Standards

EN/IEC 61000-4-18 & EN/IEC 61000-4-10 

Model

OCS 500N6.1

Oscillation frequency:

100 kHz and 1 MHz ± 10 %

Voltage (o.c.) at HV output

250 V - 3,000 V ± 10 %

Voltage (o.c) at line output

250 V - 2,500 V ± 10 %

Rise time

75 ns ± 20 %

Decaying

Peak 5 to be > 50% of peak 1 value

Peak 10 to be < 50% of peak 1 value

Source impedance

200 ohm ± 20 %

Polarity

Positive, negative

Repetition rate

Max. 50 /s for 100 kHz and Max. 500 /s for 1 MHz

Burst duration

At least 2 s

Trigger Circuit 


Release of pulses

Automatic, manual, external

Synchronization

0° - 360°, resolution 1°

Output


Direct

Via HV-safety lab connectors

Coupling mode

Line to line Line(s) to ground (PE)

DUT supply 1ph-16 A

AC: 250 V/16 A; 50/60 Hz

DC: 250 V/16 A

CRO trigger

5 V trigger signal for oscilloscope

Test Routines


Quick Start

Immediate start; easy-to-use and fast

Standard Test routines

As per IEC 61000-4-10, Level 1 - 5

User Test routines

Change polarity after n pulses

Change coupling after n pulses

Change voltage after n pulses

Change phase angle after n pulses

General Data


Dimensions, weight

19"/6 HU, approx. 28 kg (1-phase)

Supply voltage

115/230 V +10/-15%

Fuses

2 x T 2 AT (230 V);

2 x T 4 AT (115 V)