EM Test NX5 bsp-1-300-16

Rent 5 kV Surge & EFT Generator
In Stock - Order by 3 p.m. ships today
  • Configuration: 5 kV Surge, 5.5 kV Burst, & Power Fail
  • Built-in single phase CDN Max 300 V/16 A AC or DC
  • Laptop with iec.control software included
  • External Three-phase & Data Line CDNs Available
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Conducted Immunity System
  • Laptop & Power Cord
  • Test System Power Cord
  • Printed Manual 
  • Calibration Documentation
  • ESC EUT Power In Cord
  • ESA 1.6 EUT Supply Adapter
  • SCC AD Short Circuit Interlock
  • SWLAD Warning Lamp Adapter Interlock
  • Ethernet Cable
  • Software on USB Stick
  • Software License
  • UOC Optical Converter USB to LWL
  • 5m. Orange Fiber-optic cable
  • EFT Ground Strip
  • Case
  • ESA 1.6 EUT Supply Adapter
  • SCC AD Short Circuit Interlock
  • SWLAD Warning Lamp Adapter Interlock
  • Ethernet Cable
  • Software on USB Stick
  • Software License
  • UOC Optical Converter USB to LWL
  • 5m. Orange Fiber-optic cable
  • EFT Ground Strip
  • Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The compact Next Generation NX5 is the most versatile tester to address transient and power fail requirements for both international and commercial standards.

Featuring an easy-to-use color touch screen, the NX5 provides an economical solution for pre-compliance immunity testing as well as full-compliance testing and CE Marking. Its internal single-phase Coupling/Decoupling Network (CDN) can be extended for testing three-phase EUTs by means of an automatically controlled external CDN up to 200 A per phase. EM TEST supplies a large range of accessories for various applications such as magnetic field tests and more.

Benefits

The compact NX5 is a standalone generator which includes everything necessary to perform fully compliant tests. With separate power mains supply inputs, it allows the utilization of different EUT supply voltages for maximum flexibility.

The NX5 can be operated manually from the intuitive front touch screen or remotely via its built-in Ethernet, USB or optical interface. Failure inputs allow control of an ongoing test sequence based on the state of the EUT. Monitoring outputs (BNC) offer easy signal verification and measurements. For enhanced safety requirements, features like interlock and a warning lamp are available.

NX5 is the first generator that recognizes the connected EUT power configuration. Only coupling selections to active lines are enabled. Non existing lines will be disabled from the menu settings. Pre-programmed routines with common Test Standards allow maximum user convenience. Quick Start Test routines where parameters can be changed during susceptibility level evaluation are also available.

General Data
Interfaces:
Serial interface
2 x USB A for memory stick,
1 x USB B for service only,
Opto - Link to USB for remote
Lan
Ethernet for remote
Analog output
0 - 10 VDC to control an external transformer
Sys.link
26 pin high density connector to control an external coupling network
Fail inputs
EUT monitoring via input (one each)
EUT Monitor 1
EUT Monitor 2
Ext. Trigger
BNC Ext. Trigger IN pos slope 5 V
Ext. Sync Input
Differential input,
50 V - 690 VAC,
2 x 4 mm MC Safety connectors
Dimensions and Weight:
16 A models
19"/3 HU, 500 mm deep, approx. 21.8 kg
32 A models
19"/6 HU, 500 mm deep, approx. 40 kg
Environment:
Temperature
10 C to 35 C
Humidity
30 % to 75 %, non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar)
Mains:
Supply voltage
85 V - 264 V
Frequency
50/60 Hz
Power
approx. 75 W
Fuses
115 V: 2 x 4 A slow blow, 230 V: 2 x 2 A slow blow
Safety:
Safety standard
IEC/EN 61010
Security circuit
Control input (24 VDC)
Warning lamp
Floating contact (max. 60 V/2 A)
Accessories Included:
Mains supply
Plug depends on the country of use
EUT supply
Plug depends on the country of use
EUT adapter
Socket depends on the country of use
Operation manual
Calibration certificate
iec.control remote control software
Specifications:
Burst Module
As per IEC/EN 61000-4-4 and EN 61000-6-1, -6-2
Test voltage
200 V - 5,500 V +/- 10%; 100 V - 2,750 V +/- 10% into 50 ohm
Pulse shape
5/50 ns into 50 ohm and 1,000 ohm
Rise time tr
5 ns +/-30% into 50 ohm;
5 ns+/ 30% into 1,000 ohm
Pulse width td
50 ns +/-30% into 50 ohm;
50 ns -15/+100 ns into 1,000 ohm
Source impedance
50 ohm
Polarity
Positive/negative
Trigger Circuit:
Trigger of bursts
Automatic, manual, external
Synchronization
0 - 360 Degree, resolution 1 Degree (16 - 500 Hz)
Burst duration (td)
td = 0.10 ms - 9,999 ms
Repetition rate (tr)
tr = 10 ms - 9,999 ms
Spike frequency
f = 1 Hz - 1,000 kHz
Test duration
T = 0:01 min - 99:59 min
T > 99:59 min --> endless
Outputs:
Direct
Via 50 ohm coaxial connector
Coupling mode
L, N, PE; all combinations
EUT supply
AC: 300 V / 400 V, 50/60 Hz
DC: 300 V / 400 V,
Current: 16 A / 32 A
CRO trigger
5 V trigger signal for oscilloscope
Test Routines:
Quick Start
On-line adjustable parameters, easy-to-use
Standard Test routines
As per IEC/EN 61000-4-4, Levels 1 - 4
As per IEC/EN 61000-6-1, -6-2
As per ECE R-10 Rev5
Extended Test routines
Change voltage after T,
Frequency sweep within one burst,
Frequency sweep with constant number of pulses,
Frequency sweep with constant burst duration,
Synchronous burst release,
Random burst release
Combination Wave Surge:
Surge Module
As per IEC/EN 61000-4-5 and IEC/EN 61000-6-1, -6-2
Voltage (o.c.)
160 V - 5,000 V +/- 10%
Pulse front time
1.2 us +/- 30%
Pulse duration
50 us +/- 20%
Current (s.c.)
Max. 2,500 A +/- 10%
Pulse front time
8 us +/- 20%
Pulse duration
20 us +/- 20%
Polarity
Positive/negative/alternating
Trigger Circuit:
Release of pulses
Automatic, manual, external
Synchronization
0 - 360 degrees, resolution 1 degree
Repetition rate
max. 1 Hz (1 s - 9,999 s)
Event counter
1 - 99,999, selectable
Outputs:
Direct
Via HV connectors for external coupling networks
Coupling mode
Line to line
Line(s) to ground
EUT supply
AC: 300 V / 400 V,
50/60 Hz DC: 300 V / 400 V,
Current: 16 A / 32 A
CRO trigger
5 V trigger signal for oscilloscope
Measurements
CRO U-monitor
10 Vp at 5,000 V
CRO I-monitor
10 Vp at 2,500 A
Peak voltage
5,000 V in the touch display
Peak current
2,500 A in the touch display
Overcurrent protection
Breaks the Surge test when the surge current is over the limit,
Limiter for differential mode,
Limiter for common mode
EUT current
RMS current, Range 50 A, < +/-5%
EUT overcurrent protection
Breaks the test when the EUT current is over the limit,
Test Routines:
Quick Start
One-line adjustable parameters, easy-to-use
Standard Test routines
As per IEC/EN 61000-4-5,
As per IEC/EN 61000-6-1,
As per IEC/EN 61000-6-2,
Manual Standard Test routine
Extended Test routines
Voltage iteration after n pulses,
Angle iteration stepwise,
Phase angle random iteration,
Change coupling after n pulses,
Change phase angle after n pulses
Pulsed Magnetic Field
as per IEC/EN 61000-4-9
Test levels 100, 300 and 1,000A/m
Test level continuously adjustable under Quick Start
Power Fail:
As per
IEC/EN 61000-4-11,
IEC/EN 61000-4-29
and IEC/EN 61000-6-1, -6-2
Channel PF1/PF2
AC voltage: max. 300 V / 400 V
AC current: max. 16 A / 32 A
DC voltage: max. 300 V / 400 V
DC current: max. 16 A / 32 A
Frequency
16 Hz - 500 Hz and DC
Switching time
> 1 us < 5 us into a 100 ohm resistive load (SVP 100)
Inrush current
> 500 A
Protection
Both channels are protected against short-circuit conditions.
Trigger Circuit:
Trigger of events
Automatic, manual, external
Synchronization
0 - 360 degrees, resolution 1 degree (16 - 500 Hz)
Repetition rate
10 ms - 9,999 s
Event duration
10 us - 99.999 s
Event counter
1 - 99,999, selectable
Outputs:
EUT terminals
L, N and PE
CRO trigger
5 V trigger signal for oscilloscope
Measurements:
EUT voltage (rms)
In the touch screen
EUT current (rms)
In the touch screen
MON V
Measurement of the EUT voltage, built-in divider:
300 V: 42,5:1, 10 V =425 Vpk,
400 V: 56.6:1, 10 V =566 Vpk
MON I
Measurement of the EUT current,
16 A: 7 A/V; 10 V =70 Apk,
32 A: 10 A/V; 10 V =100 Apk
Test Routines:
Quick Start
On-line adjustable parameters, easy-to-use
Standard Test routines
As per IEC/EN 61000-4-11 for AC supplies
As per IEC/EN 61000-4-29 for DC supplies
As per EN 61000-6-1, -6-2 Manual Standard Test routine
Extended Test routines
Voltage variation, control of an external variac,
Phase angle iteration, Reduced time iteration,
Angle inverse mode, Random by step and list Inverse mode
50/60 Hz magnetic field
As per IEC/EN 61000-4-8 Test levels 1, 3, 10 and 30 A/m with external current transformer MC 2630, Test levels 100, 300 and 1,000 A/m with external current transformer MC 26100
Video Guides
Compact NX5 & Software Overview
Verifying EFT Pulses with the EM Test NX5
Related Videos
EM Test Coupling NX7 32 Amp CDN Overview
Dips Testing with V4780 & NX7