Solar 9354-2 - Front Side
Solar 9354-2 - Front
Solar 9354-2 - Rental MIL-STD-461 CS116 & DO-160 Sec Video Guide
Solar 9354-2 - Back
Solar 9354-2 - Front Side Above

Solar 9354-2

Rent MIL-STD-461 CS116 Transient Generator

In Stock & Ready To Ship
Orders by 3pm ship today

The Solar 9354-2 is a MIL-STD-461 CS116 transient generator providing six damped sine frequencies from 10 kHz to 100 MHz plus three double-exponential pulse waveforms for susceptibility testing.

Features

  • 3 Double Exponential Pulse 6.4 μs, 70 μs, & 120 μs
  • 6 Damped Sinusoidal Pulses 10 kHz - 100 MHz 
  • Compliant to MIL-STD-461 CS116
  • Required Accessories Included in CS116 Kit
  • Current ISO 17025 Accredited Calibration
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period
  • Transient Generator
  • Power Cord
  • Printed Manual
  • Calibration Documentation 
  • Case
  • Can't find something? Contact Us

Description

The Solar Model 9354-1 and 9354-2 Transient Generators were especially designed for the performance of a variety of pulse susceptibility tests on subsystems and/or equipment, in accordance with MIL-STD-461E/F, Method CS116; also capable of limited testing for RTCA DO-160D, Section 22.

The Model 9354-1 and 9354-2 Transient Generators provide nine selectable waveforms, including six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) and three double exponential pulses (6.4 µS, 70 µS, 500 µS on Model 9354-1. The Model 9354-2 also has three double exponential pulses (6.4 µS, 70 µS, and 120 µS).
Auto pulsing of the sinusoidal repetition rate is internally adjusted from 0.5 to 1.0 pulse per second. A front panel-mounted pushbutton can be used to manually trigger single pulses. The peak amplitude of the selected output pulse is adjustable as a percentage of the charge voltage.The six damped sinusoidal waveforms were designed to meet the requirements of MIL-STD-461E/F, Method CS116. Continuous tunable frequencies can be obtained by the use of the optional variable frequency modules.

The 1 MHz, 10 MHz, and the three double exponential pulses were designed to provide pre-compliance testing of RTCA DO-160D, Section 22. Table 2 lists the test levels that can be achieved from the Models 9354-1 and 9354-2

Specifications:
DAMPED SINUSOID PULSES
10 kHz
Open circuit voltage 30 V
Calculated short circuit current 120 A
Source impedance <0.25 Ohms
100 kHz
Open circuit voltage 300 V
Calculated short circuit current 120 A
Source impedance <2.5 Ohms
1 MHz
Open circuit voltage 3200 V
Source impedance <25 Ohm
10 MHz
Open circuit voltage 3200 V
Calculated short circuit current 128 A
Source impedance <25 Ohm
30 MHz
Open circuit voltage 1000 V
Calculated short circuit current 20 A
Source impedance <50
100 MHz
Open circuit voltage 300 V
Calculated short circuit current 6 A
Source impedance <50 Ohm
DOUBLE EXPONENTIAL PULSES
6.4 uS
Rise time 100 nS
Open circuit voltage 1600 V
Calculated short circuit current 800 A
Source impedance<2.0 Ohms
70.0 uS
Rise time 6.4 uS
Open circuit voltage 1600 V
Calculated short circuit current 800 A
Source impedance <2.0 Ohms
500 uS (9354-1)
Rise time 50 uS
Open circuit voltage 1600 V
Calculated short circuit current 400 A
Source impedance <4.0 Ohms
120 uS (9354-2)
Rise time 40 uS
Open circuit voltage 750 V
Calculated short circuit current 400 A
Source impedance<4.0 Ohms
Solar 9354-2 Datasheet
Download
Solar 9354-2 User Manual
Download

Video Library

Video Guides
Related Videos

FAQs

Yes. Its six damped sinusoidal waveforms are designed for MIL-STD-461 CS116 testing across the required 10 kHz to 100 MHz frequency range.

The generator provides fixed damped sinusoidal frequencies of 10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz.

The Solar 9354-2 includes three double-exponential pulse waveforms with nominal durations of 6.4 µs, 70 µs, and 120 µs.

Both models provide the same six damped sinusoidal frequencies. The primary difference is the longest double-exponential waveform: 500 µs on the 9354-1 and 120 µs on the 9354-2.

The generator supports automatic pulsing at approximately 0.5 to 1 pulse per second and manual single-pulse triggering. Output amplitude is adjustable from 25% to 100% of the selected discharge voltage.

Rent the Solar 9354-2

Weekly, two-week and monthly rentals available.

Questions?630-887-0329
Solar CS115 & CS116 Rental Kits

Get a Conducted Susceptibility Setup

Expand your Solar 9354-2 rental with compatible equipment for a complete MIL-STD-461 test setup. Add variable-frequency modules, the Solar 9355-1 CS115 generator, and the accessories required for injection and verification.

  • Solar 9354-2 fixed frequencies from 10 kHz to 100 MHz
  • Optional tunable-frequency modules for additional CS116 testing
  • Solar 9355-1 and complete accessory packages for CS115

Solar Equipment for CS115 and CS116 Testing

Solar MIL-STD-461 CS116 & CS115 Front

Solar MIL-STD-461 CS116 & CS115 Accessory Package

  • Includes Injection Probes, Monitoring Probe, & Attenuators
  • Common MIL-STD-461 CS116 & CS115 Required Accessories
  • Ideal for Rental with Solar 9354-2 & 9355-1 Generators
  • 9123-1N Monitoring Probe Includes ISO 17025 Calibration
View Equipment
Solar 9554-1M/6M - Rent Variable Frequency Module

Solar 9554-1M/6M - Rent Variable Frequency Module

  • Covers 1 MHz to 6 MHz Frequency Range
  • Used with Solar 9354-2/-1 Pulse Generators 
  • Meets Requirements for MIL-STD-461 CS116

View Equipment
Solar 9355-1 - Front Side

Solar 9355-1 - Rent MIL-STD-461 CS115 Pulse Generator

  • 2 kV 2 ns Rise/Fall Time Pulse Generator 
  • Compliant MIL-STD-461 CS115 Transients 
  • Selectable Pulse Rate .6 to 150 per second
  • Charged line output voltage 10V to ≈2kV
  • Current ISO 17025 Accredited Calibration
View Equipment
Requesting Quote For
Solar CS115 & CS116 Rental Kits
Need Help Choosing?

Our team can review your requirements and recommend the right equipment.

630-887-0329
info@transientspecialists.com

Request a Quote
Tell us what you need and our team will provide rental or purchase options.
No obligation • Fast Response