Teseq NSG 3060A - Teseq Transient Generator Test System

Teseq 6kV Module Solution:

  • Conifgured 6.6kV Surge & 5.5kV EFT (IEC)
  • Built-in CDN AC/DC Max 300v/16amps 
  • NSG 3060A-IEC Model (IEC 61000-4-4/5)
  • Newest Generator in Teseq NSG Series
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

NSG 3060A Equipment

Description

Overview

Teseq’s new NSG 3060A conducted immunity generator takes the proven, user-friendly design of the highly successful NSG 3000 series to a new level. This innovative design uses modular architecture to provide a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.

Designed to fulfill requirements for CE mark and ANSI C62.41 testing, the NSG 3060A performs tests for Combination wave surge, Ring wave and Electrical Fast Transient (EFT) pulses as well as Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.

Using state of the art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements. With its powerful processors, the NSG 3060A can completely fulfill the unique coupling requirements specified by ANSI C62.41. This standard requires that the pulse amplitude be adjusted for the phase position of the pulse on the AC mains, and for the amplitude of the mains voltage.

A 7” touch panel display with superb contrast and color is the most striking feature of the new NSG 3060A. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment.

The user-friendly graphic display speeds test setup. Each parameter’s value is highly visible, and all settings can be quickly selected and modified with the generously sized touch input buttons. A stylus is not necessary, and ramp functions are programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values changed easily.

The users can make manual parameter changes using the thumbwheel while a test is under way, providing an effective and fast method for identifying critical threshold values. The Test Assistance (TA) function allows users to initiate standardized test with just a few “clicks” to achieve quick, reliable results in a development environment.

The NSG 3060A has an Ethernet port for external PC control. The Windows-based control software simplifies test programming and allows compilation of complex test sequences with diverse pulse types. Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term test

Data SheetUser Manual

Specifications

Common Standards

EN/IEC 61000-4-4EN/IEC 61000-4-5

ANSI C62.41C62.45, UL 1449

Electrical Fast Transients (EFT/Burst)

IEC 61000-4-4

Pulse amplitude:

±200 V to 4.8 kV (in 1 V steps) - open circuit

±100 V to 2.4 kV (50 Ω matching system)

Burst frequency:

100 Hz to 1000 kHz


Polarity:

positive / negative / alternate

Repetition time:

10 ms to 9'999 ms

Burst time:

0.01 ms to 9'999 ms, single pulse

Test duration:

1 s to 9’999s, 1 min to 1600 min, endless

Phase synchronization:

asynchronous, synchronous 0 to 359º (in 1º steps)

Combination Wave Surge:

 

Pulse voltage (open circuit):

±200 V to 6.6 kV (in 1 V steps)

Pulse current (short circuit):

±100 A to 3.3 kA

Impedance:

2/12 Ω

Polarity:

positive / negative / alternate

Pulse repetition:

10 s* up to 9’999 s (in 1 s steps)

Test duration:

1 to 99’999 pulses, continuous

Phase synchronization:

asynchronous, synchronous 0 to 359º (in 1º steps)

Coupling:

ANSI / IEC / external

* Repetition rate depends on voltage:

200 to 4400 V = 10 s repetition time

4401 to 6600 V = 20 s repetition time

All Accessories

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

NSG 3060A Options & Accessories List

Item Capabilities
CDN 3063A-C32 Three phase 480 V / 32 A automatic coupling decoupling networks for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV
CDN 3063A-C63

Three phase 480 V / 63 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV

CDN 3063A-C100

Three phase 480 V / 100 A automatic coupling decoupling network for Burst/EFT up to 4.8 kV, Surge, Ring Wave pulses up to 6,6 kV

CDN 3425 Burst EFT capacitive coupling clamp for data line coupling per IEC 61000-4-4

CDN 117A-C6-4-1

Coupling networks for unsymmetrical signal-/data lines (surge)

CDN 118A-C6-4-1

Coupling networks for symmetrical signal-/data lines (surge)

CDN HSS-2

Teseq Burst/EFT couple pulses to data lines.

PVF BKIT 1

Burst/EFT verification set

MD 210

Voltage differential probe 7 kV common / differential 1000:1 / 100:1

MD 300

Current probe 5 kA

Accessories for IEC/EN 61000-4-11


TVT 1-250-16

Manual step transformer, 16 AAC, 0/40/70/80%

VAR 3005A-S16

Automatic single variable transformer, 1 x 16 A

Accessories for IEC/EN 61000-4-8/-4-9


MFO 6501A

Manual magnetic field option -4-8

MFC 30

Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9

MFC 300

Magnetic field coil 1 x 1 m; max. 330 A/m -4-8

  

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this immunity generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

 

  • EMC Directives
  • UN ECE R10 (Automotive)
  • IEC/EN 61000-4-4
  • IEC/EN 61000-4-5
  • IEC/EN 61000-4-8
  • IEC/EN 61000-4-9
  • IEC/EN 61000-4-11
  • IEC/EN 61000-4-12
  • IEC/EN 61000-4-29
  • ANSI/IEEE C62.41
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 50370
  • EN 61643
  • EN 300386-2
  • EN 300386 V1.3.2
  • EN 301489-1
  • EN 301489-7
  • EN 301489-17
  • EN 301489-24
  • FCC 97-270 (part 68)
  • IEC 60255-1
  • IEC 60601-1-2
  • IEC 61009-1
  • IEC 61326
  • IEC 61850-3
  • ITU-T K.12
  • ITU-T K.20
  • ITU-T K.21
  • ITU-T K.28
  • ITU-T K.41
  • ITU-T K.44
  • ITU-T K.45

Videos

NSG 3060 - Overview & Setup: Transient Specialists

 

Description: This video provides an overview of the NSG 3060 immunity test generator for surge, ringwave, and electrical fast transient (EFT) testing with the CDN 3061 single phase coupler decoupler 270v/16amps. It talks briefly about capabilities of the test system, setup, and additional considerations. All of these pieces of test equipment are available for rental and come with ISO 17025 calibrations.

 

NSG 3060 -Multifunction Genertor Teseq

 

Description: This video made by Teseq, now owned by Ametek, provides overview of this test system including the capabilities and changing testing parameter. Video also includes both CDN 3083 & CDN 3061 coupling decoupling networks.

 

You may also like