Conducted RF Immunity Test Accessories

RF Current Injection Clamp

In Stock

Coupling/Injection Clamp Features 

      • Frequency: 150kHz to 1GHz (.015MHz to 1000MHz)
      • FTC 101 Decoupler Included (IEC 61000-4-6)
      • Free Technical Support & 2 Days Free Transit
      • Max Power 100 Watts
      • Compliant to IEC 61000-4-6 Newest Edition

Overview

The EM 101 made by EM Test (Lüthi) electromagmetic (EM) clamp is an RF current lnjection clamp, having inductive and capacitive coupling and allowing the induction of large currents on cables in the frequency range of 0.15 to 1000 MHz. The rental of this coupling clamp also includes the FTC 101 decoupling clamp. 

This EM Test RF coupling clamp induces a current on a cable by using inductive and capacitive coupling at the same time. The EM101 design has made it possible to improve the frequency range up to 1000 MHz by modifying the primary winding. This EM Test product is designed for testing to EN/IEC 61000-4-6 and many other conducted RF EMC standards.

Teseq RF Injection Clamp

In Stock

Current Injection Clamp Features 

      • As Specified in IEC61000-4-6 (incl. edition 4 and EN 61000-4-6:2014)
      • Very Efficient Coupling
      • Can be used on almost Any Cable
      • Free Technical Support & 2 Days Free Transit
      • Ruggedly Designed & Improved Locking System
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The KEMZ clamp made by Teseq is an RF current lnjection clamp, having inductive and capacitive coupling and allowing the induction of large currents on cables in the frequency range of 0.15 to 1000 MHz. This Teseq RF coupling clamp induces a current on a cable by using inductive and capacitive coupling at the same time. The KEMZ design has made it possible to improve the frequency range up to 1000 MHz by modifying the primary winding. This EM Test product is designed for testing to EN/IEC 61000-4-6 and many other conducted RF EMC standards.

RF CDN Test Equipment

In Stock

Conducted RF CDN Features 

      • Frequency: 10 kHz – 230 MHz
      • Input Power rating: 100 watts
      • Maximum AC Power 100 V /1.5 A

BCI Injection Probe

In Stock

Conducted RF Injection Probe Features 

      • Frequency 10 kHz – 230 MHz
      • AC/DC: max. 125 V /1.5A
      • F-33-2 Current Probe ISO 17025 Calibration
      • AE/EUT: Sub-D15 connectors
      • Comes with Current Probe, Fixture, & Adapter
      • Free Technical Support & 2 Days Free Transit

The F120-9 A (F120 9) is a Fischer Custom Communications bulk current injection probe for testing products for immunity to conducted RF per IEC 61000-4-6. The F-120-9A has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 230 MHz. The useable frequency range is 10 kHz - 230 MHz with an insertion loss of less than 8 dB between 150 kHz – 200 MHz. The input power rating is 100 watts for 30 minutes.

RF CDN Test Equipment

In Stock

Conducted RF CDN Features  

      • For 4 unscreened/unshielded unsymmetrical/unbalanced lines
      • Frequency 150 kHz - 230 MHz
      • AC: max. 63 V/1.5 A
      • AE: 4mm safety lab connectors
      • EUT: 4mm safety lab connectors

EMTest CDN for 4 unshielded unsymmetrical lines to test  immunity to conducted RF per EN IEC 61000-4-6 and IEC/EN 60945.

RF CDN Test Equipment

Conducted RF CDN Features  

      • CDN for 3 Conductors Powerline 
      • Frequency 150 kHz - 300 MHz
      • Three-Line (M3) Model - 25Amp Per Line
      • Fully Compliant CISPR 16-1-2 and IEC 61000-4-6
      • RF Input Voltage: 40 V (Max)

Overview

This CDN complies the test Standards of IEC / EN 61000-4-6. The disturbance signals are coupled to each conductor in the supply lines. This standard M series CDN has a current rating of 25 Amps and a frequency range of 150 kHz - 230 MHz.

BCI Injection Probe

In Stock

Conducted RF Injection Probe Features

      • Frequency 10kHz-400MHz
      • Insertion Loss <9 dB or Less
      • Current Probe ISO 17025 Calibration
      • AE/EUT: Sub-D15 connectors
      • Comes with Current Probe, Fixture, & Adapter
      • Free Technical Support & 2 Days Free Transit

The F120-6A is a Fischer Custom Communications bulk current Injection Probe for testing products for immunity to conducted RF per Do 160 sec 114 & 20, Mil Std 461 CS114. Includes calibration fixture. The F-120-6A is a broadband, high effi ciency injection probe. Large RF currents can be coupled on to a signal or power circuit under test between 10 kHz – 400 MHz.

RF CDN Test Equipment

In Stock

Conducted RF CDN Features  

      • For 5 AC supply lines
      • Frequency 150 kHz - 80 MHz
      • AC: max. 3 x 750 V/32 A
      • AE: 4mm safety lab connectors
      • EUT: 4mm safety lab connectors

EMtest three phase 5 line (L1,L2,L3,N,Pe) CDN for testing products for immunity to RF per EN IEC 61000-4-6.

RF CDN Test Equipment

In Stock

Conducted RF CDN Features  

      • For 2 or 3 AC/DC supply lines (switchable)
      • Frequency 150 kHz - 300 MHz
      • AC/DC: max. 250 V/16 A
      • AE: IEC 60320/C14 connector
      • EUT: 4mm safety lab connectors

Overview

EMTest Single phase 2 or 3 line CDN for testing products for immunity to conducted RF per EN IEC 61000-4-6. Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines. Dedicated CDNs are also used as per CISPR 15 and EN 55015 for measurement of emission. A large range of appropriate coupling/decoupling networks as well as the necessary accessories for standard compliant levelling are avialable.