Ask Us About: Rent EMC/EMI Test Systems, Generators, & Equipment
Transient Specialists
Filters
Recent Views
Rent EMC/EMI Test Systems, Generators, & Equipment
Conducted Immunity Equipment
Rent test equipment for ESD, transients, DOW & common mode testing to variety of standards.
Radiated Immunity Systems
Get fast deliveries on power amplifiers, signal generators, antennas, e-field probes and others!
Conducted Emissions Equipment
Rent monitoring systems designed for flicker, harmonics, CISPR 22, & ISO 7637.
Complete Test Systems
Rent complete test solutions and systems for many common EMC & EMI requirements
Flexible Terms
Get weekly, two week, and monthly rental periods on all test systems and generators
Diverse Inventory
We offer a wide range of equipment from many of the major manufacturers
Commercial
Military/Avionics
Product/Application
Get the best rates - Same Quality Equipment
- Required to use ECAT Modules
- Firmware Updates Provided Upon Request
- Additional Sections can be Added
- 15 kV/ 7.5 kA Surge Generator
- External CDN 3153-S63 Included
- Compliant to IEC 61000-4-5
- -15 to +60 Volts 100 Amps Continuous
- High Bandwidth up to 150 kHz
- 300 Amp Inrush Current Capability
- -15 to +60 Volts 25 Amps Continuous
- High Bandwidth up to 150 kHz
- 75 Amps Inrush Current Capability
- Configuration: 5 kV Surge, 5.5 kV Burst, & Power Fail
- Built-in single phase CDN Max 300 V/16 A AC or DC
- Laptop with iec.control software included
- Verification/calibration Kit for IEC 61000-4-4
- INA 265B 50 Ohm & INA 266A 1 k Ohm Termination
- For peak voltages up to 8.8 kV
- Complies with IEC 61000-4-4 Ed 2 & 3
- Maximum Burst Voltage 8 kV
- Used for Test EFT/Burst on Data Lines
- Single Phase Dips Transformer
- Maximum 264 Volts 16 Amps
- Designed for Haefely AXOS Series
- Switch for Power Lines 100 A and Data Lines 2 A
- Fast Switch with Rise/Fall Times of 200ns
- Pulses E10 and E13 of the LV 124/LV 148
- Frequency 10 kHz – 50 MHz
- 0.25 µF Coupling Capacitor
- Designed for MIL-STD-461D/E/F/G
- Frequency Sweep, Short, & Long Capabilities
- Laptop with TRA3000 Included with System
- Includes EMC Partner P3 & EXT-IMU C-SHORT
- Low EMI Sensitivity
- 200:1 Attenuation
- Can be used with Most Oscilloscopes
- Low EMI Sensitivity
- 200:1 Attenuation
- Can be used with Most Oscilloscopes
- Required for 30 kV Testing
- Connects Directly to Front of Simulator
- Rented with EMC Partner ESD3000
- 7 kV Surge, 5.5 kV EFT, & 7 kV 100 kHz Ringwave
- Built-in CDN Max 264 V/16 A AC or 220 V/10 A DC
- Compliant to ANSI Coupling Requirements
- IEC 60601-2-25 and -2-27:2011 Generator
- Integrated Energy Measurement
- Output Voltage & Polarity From Front Panel
306 products
Overview
General Overview
Electromagnetic compatibility equipment covers a wide range of test equipment designed to ensure that electrical and electronic equipment functions in its anticipated electrical environment. Often times tester are built around compliance to a particular standard, or group of standards, like the EM Test NX5 Platform and associated surge and electrical fast transient standards. These test systems offer different capabilities depending upon the modules installed and testing capabilities can vary significantly. Many standards place specific requirements on the test setup and accessories. We often bundle these accessories and generators to provide compliant systems, like the IEC 61000-4-3 & IEC 61000-4-6 test packages below.
Rental Test Systems
Our rental test systems cover a wide range of standards and requirements and arrive ready for testing to begin. Often times, as with our automotive conducted immunity systems a laptop with the associated manufacturer software and license is included. This allows for quick an efficient testing and eliminates the need for timely software installations or running systems exclusively through the front panel interface. Our inventory is constantly updated and meets the latest version of the standards. We also offer current ISO 17025 accredited calibrations included in the rental price. As with all our distributed ESD systems, including the Teseq NSG 435, these systems can be rented and shipped the same day via our website.
Surge & EFT
Transient Systems
Transients, a common part of conducted immunity testing span many different applications and electrical and electronics systems. The two most common tested interference occurrence are surge (combination wave) and electrical fast transients (EFT). These series of immunity occurrences fall under IEC 61000-4 series of tests (IEC 61000-4-5 & IEC 61000-4-4 respectively).A few major considerations with these type of equipment, the associated test voltage, coupling decoupling network (CDN), and associated accessories. Often times single phase mains CDNs are built into the platform, meeting many testing requirements, however external couplers for a variety applications are available.
4kV Rental Surge & Bust Generators
Our rental inventory of both combination wave surge generators and electrical fast transient systems provide a diverse set of testing capabilities including up to 15kV capabilities with the Teseq NSG 3150 system. These systems all come with current ISO 17025 accredited calibrations and often a laptop with software installed. The associated systems also arrive with all required cords and license codes allowing for testing to begin upon arrival.
Haefely - Axos 5- 5kV EFT/Burst & Surge Immunity Generator System
- Front Panel Attenuated Voltage & Current Monitoring
- Built In 264v/16A AC 220V/10A DC Single Phase Coupler
- Rent FP-COMB 32 3-Phase 480V/32Amp AC/DC CDN
- Compact & Easy to use - No Software or License Required
- Dips Transformer DIP 116 Available IEC 61000-4-11
- Rent both 16 Amp & 32 Amp CDN configurations
- Variety of External Automatic & Manual CDNs
- Rent Coupling NX7 (bsr-3-480-32) 3-Phase 480V/32Amps CDN
- Very compact & 7inch Touch Screen - Programmed Standards
- Laptop with EM Test Control Software Included with Rentals
- Current ISO 17025 Accredited Calibration
EMC Partner - IMU4000
- 4.1kV Bi-wave Surge & 4.4kV EFT/Burst
- Same Platform for IEC 61000-4-16 Solution
- Plug and Play" architecture - Quick to Setup
- Programmed Standards & Touch Screen
- Includes IEC 61000-4-11 Dips Capabilities 6Amps
- Current ISO 17025 Accredited Calibration
Conducted RF
RF systems, which include a combination of required components, often used in this conducted immunity standard. The systems include several key components for testing to IEC 61000-4-6 often including amplifier, power meter, signal generator, dual directional coupler, sensors and screen interface usually accompanied by software. The NSG 4070 comes in several different wattage variations including 110 watt, 80 watt, and 60 watt with associated power meters and signal generator built in. Given the different test levels and evaluation of testing environment, often times external amplifiers can be used in place of the built in the amplifier. (additional dual directional coupler and associated equipment required). The below picture are the most common systems made by Teseq and EM Test.
Teseq - NSG 4070
- Up to 80Watt Built in Amplifier 150kHz-230MHz
- External 100 Watt CBA 400M-110 Rental Available
- Integrated signal generator 9 kHz - 1 GHz
- Conducted & Radiated Solution - IEC 61000-4-6/-3
- Laptop with Software included with Rental
- Current ISO 17025 Accredited Calibration
CDN
The preferred method of testing for this standard is coupler decouple networks (CDNs). This is because it fits it is easily reproducible and offers protection of the AE. There is also a given contingency that if the CDNs are not available on the market, then other injection methods maybe used. There are seven different variations depending upon the type of cable being used, CDN-S1, CDN-M1/-M2/-M3, CDN-AF2, CDN-T2, CDN-T4, CDN-AF8, and CDN-T8. These are presented in diagrams 6.2.2.2, 6.2.2.4, 6.2.2.3, and 6.2.2.5.
EM Test - CDN M2/M3/16A
- 2 or 3 AC/DC Supply Lines/Cables
- Frequency 150 kHz - 300 MHz
- AC/DC Max - 250V/16A 1-Phase
- CDN Designed for EN/IEC 61000-4-6
EM Clamps
Another common method for testing conducted RF immunity is the electromagnetic (EM) clamp. For this standard it specifies operating frequencies from .15MHz-80MHz however, often times they cover up to 1GHz for added testing capabilities. These are ideal as they allow for a variety of different types of cable and are readily available on the market, both for purchases and rentals. Below you will find two common EM Clamps that can be used with a variety of systems. The EM101 clamp also includes a decoupling clamp that can be used to help protect the remaining equipment connected to the EUT.
EM Test - EM 101
- Frequency: 150kHz to 1GHz
- FTC 101 Decoupler Included
- Max Power 100 Watts
- Compliant to IEC 61000-4-6 Newest Edition
Transient Specialists
Filters