Keytek ECAT E509A - Bellcore GR-1089-CORE 10/1000us Network

Availability:
In Stock - Order By 3PM Ships Today!

Keytek 10/1000us Module:

  • 10/1000us 600V, 1kV, & 1.5kV Generator
  • Bellcore GR-1089-CORE Test Solution
  • Can Be Rented w/without E103 System

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Keytek ECAT - Test Accessories

Description

Three-Terminal Telecom 10/1000us Module Features:

      • Bellcore GR-1089-CORE Test Solution
      • ISO 17025 Calibration Included
      • 10/1000us 600V, 1kV, & 1.5kV Generator
      • Can Be Rented w/without E103 System
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller 
Data Sheet

Specifications

E509 Telecordia Lightning Surge for ECATS

 

Standards

GR 1089-CORE

Open Circuit Voltage Waveform

10/1000µs,50-600V -0/+15% peak

10/1000µs,50-1000V -0/+15%peak

10/1000µs,50-1500V -0/+15%peak

Short Circuit Current Waveform

100A/side -0/+15%peak

Duration

-0/+50% for Voltage

Front Time

-30%/+0 for Voltage

Pulse Repetition Rate

1 shot/40 seconds

Weight

16kg, 35 pounds

Dimensions

21x42x52 cm, 8x16x20 inches

 

ECAT Series

Common Modules

 

ECAT Series Full Accessory
Item Capabilities
ECAT Model E411 EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
ECAT Model E412 EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following:
ECAT Model E421 FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k
ECAT Model E501B Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA
ECAT Model E502B Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT
ECAT Model E503 Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
ECAT Model E504A Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module)
ECAT Model E505A Plug-in module that produces the lightning surge waveforms required by FCC Part 68
ECAT Model E506-4W Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing
ECAT Model E508 and E508-12P Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE
ECAT Model E510A Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA
ECAT Model E511 Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards
ECAT Model E513 Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864
ECAT Model E514 Surge simulator for 10/1000 µs current waves
ECAT Model E515 Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE
ECAT Model E518 Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT
ECAT Models E521 and E522 Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits).
ECAT Model E551 A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5
ECAT Models EP61 and EP62 Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A
ECAT Model E455x Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5

  

You may also like