EM Test NX7 & 3-Phase CDN - 7kV Transient System

Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Overview

The Rent the EM Test NX7 EMI test generator to 7kV EFT and 5kV surge with a built-in 16 amp single phase coupler (220V/16Amps). This test system provides an ultra compact, easy to use, touch screen allowing for effective testing. It is the most versatile tester to address transient and power fail requirements for both international and commercial standards. An ISO 17025 accredited calibration, laptop with software, and associated cords is included with the rental.

This Immunity Test Generator includes an easy-to-use color touch screen allow for efficiently changing of testing parameters. It can be operated manually from the intuitive front touch screen or remotely via its built-in Ethernet, USB or optical interface. The NX 7 provides an economical solution for pre-compliance immunity testing as well as full-compliance testing.

This product includes many reprogrammed test routines ideal for testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11 and CE Mark. This EM Test pulse generator includes internal single-phase Coupling/Decoupling Network (CDN) that can be extended for testing three-phase EUTs by means of an automatically controlled external CDN up to 200 Amp per phase. With separate power mains supply inputs, it allows the utilization of different EUT supply voltages for maximum flexibility.

Specifications

Common Standards

EN/IEC 61000-4-4EN/IEC 61000-4-5EN 61000-4-12

ANSI C62.41C62.45, UL 1449

BURST MODULE 

 

Test voltage

200 V - 5,500 V ± 10%; 100 V - 2,750 V ± 10% into 50 ohm

Pulse shape

 5/50 ns into 50 ohm and 1,000 ohm

 Rise time tr

 5 ns ± 30% into 50 ohm; 5 ns ± 30% into 1,000 ohm

Pulse width td

 50 ns ± 30% into 50 ohm; 50 ns -15/+100 ns into 1,000 ohm

Source impedance

 50 ohm

Polarity

 Positive, negative


 TRIGGER CIRCUIT

 

Trigger of bursts

 Automatic, manual, external

Synchronization

 0° - 360°, resolution 1° (16 - 500 Hz)

Burst duration (td)

 td = 0.10 ms - 9,999 ms

Repetition rate (tr)

 tr = 10 ms - 9,999 ms

Spike frequency

 f = 1 Hz - 1,000 kHz

Test duration

 T = 0:01 min - 99:59 min T > 99:59 min --> endless

 OUTPUTS

 

Direct

 Via 50 ohm coaxial connector

Coupling mode

 L, N, PE; all combinations

EUT supply

 AC: 300 V / 400 V, 50/60 Hz DC: 300 V / 400 V, Current: 16 A / 32 A

CRO trigger

 5 V trigger signal for oscilloscope

 TEST ROUTINES

 

Quick Start

 On-line adjustable parameters, easy-to-use

Standard Test routines

 As per IEC/EN 61000-4-4, Levels 1 - 4 As per IEC/EN 61000-6-1, -6-2 As per ECE R-10 Rev5

Extended Test routines

Change voltage after T, Frequency sweep within one burst, Frequency sweep with constant number of pulses, Frequency sweep with constant burst duration, Synchronous burst release, Random burst release

 OPTIONS

 

CCI

 Capacitive coupling clamp as per IEC/EN 61000-4-4

CCI PVKIT 1

 Adapter set for capacitive coupling clamp calibration included: - Transducer plate as per IEC/EN 61000-4-4 Ed 3.0, - Support for positioning the PVF 50 on 100 mm height as the capacitive coupling clamp, - PVF AD 3 to match the Transducer plate to the PVF 50

PVF 50

 100:1 divider, 50 ohm

PVF 1000

 500:1 divider, 1,000 ohm

PVF BKIT 1

 Kit for burst pulse verification consisting of PVF 50, PVF 1000 and adapter for EUT port in a plastic case for storage

PVF AD 1

 Adapter to match PVF 50 load resistor to the EUT supply of NX-series coupling network, 3-phase coupling network

ITP

 Immunity test probes (electrical field generation)

ITP/H

 Immunity test probe (magnetic field generation)

 SURGE MODULE

 

Voltage (o.c.)

 200 V - 7,000 V ± 10%

Pulse front time

 1.2 µs ± 30%

Pulse duration

 50 µs ± 20%

Current (s.c.)

 Max. 3,500 A ± 10%

Pulse front time

 8 µs ± 20%

Pulse duration

 20 µs ± 20%

Polarity

 Positive, negative, alternate

 TRIGGER CIRCUIT

 

Release of pulses

 Automatic, manual, external

Synchronization

 0° - 360°, resolution 1°

Repetition rate

 max. 1 Hz (1 s - 9,999 s)

Event counter

 1 - 99,999, selectable

 OUTPUTS

 

Direct

 Via HV connectors for external coupling networks

Coupling mode

 Line to line Line(s) to ground

EUT supply

 AC: 300 V / 400 V, 50/60 Hz DC: 300 V / 400 V, Current: 16 A / 32 A

CRO trigger

 5 V trigger signal for oscilloscope

MEASUREMENTS

 

CRO Û-monitor

 10 Vp at 7,000 V

CRO Î-monitor

 10 Vp at 3,500 A

Peak voltage

 7,000 V in the touch display

Peak current

 3,500 A in the touch display

Overcurrent protection

 Breaks the Surge test when the surge current is over the limit, Limiter for differential mode, Limiter for common mode

EUT current

 RMS current, Range 50 A, < ±5%

EUT overcurrent protection

 Breaks the test when the EUT current is over the limit,

 TEST ROUTINES

 

Quick Start

 One-line adjustable parameters, easy-to-use

Standard Test routines

 As per IEC/EN 61000-4-5, As per IEC/EN 61000-6-1, As per IEC/EN 61000-6-2, Manual Standard Test routine

Extended Test routines

 Voltage iteration after n pulses, Angle iteration stepwise, Phase angle randomiteration, Change coupling after n pulses, Change phase angle after n pulses

Pulsed Magnetic Field

 as per IEC/EN 61000-4-9 Test levels 100, 300 and 1,000A/m Test level continuously adjustable under Quick Start

 OPTIONS

 

DCD 7 sr-4-x

 Coupling network for 4 signal/data lines as per IEC/EN 61000-4-5 Ed 3.0

DCD 7 sr-8-x

 Coupling network for 8 signal/data lines as per IEC/EN 61000-4-5 Ed 3.0

DCD 7 st-4-1

 Coupling/decoupling network for 4 unshielded symmetrical lines (communication lines) as per IEC/EN 61000-4-5 Ed 3.0 (fig. 10)

DCD 7 st-8-1

 Coupling/decoupling network for 8 unshielded symmetrical lines (communication lines) as per IEC/EN 61000-4-5 Ed 3.0 (fig. 10)

HSC 4-8

 Coupling/decoupling network for testing unshielded and shielded high-speed communication lines (Ethernet lines)

SPN 508N1

 Surge protection network to reduce the surge voltage <10 V at the A

 POWER FAIL MODULE

 

As per

 IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2

Channel PF1/PF2

 AC voltage: max. 300 V / 400 V AC current: max. 16 A / 32 A DC voltage: max. 300 V / 400 V DC current: max. 16 A / 32 A

Frequency

 16 Hz - 500 Hz and DC

Switching time

 > 1 µs < 5 µs into a 100 ohm resistive load (SVP 100)

Inrush current

 > 500 A

Protection

 Both channels are protected against short-circuit conditions.

 TRIGGER CIRCUIT

 

Trigger of events

 Automatic, manual, external

Synchronization

 0° - 360°, resolution 1° (16 - 500 Hz)

Repetition rate

 10 ms - 9,999 s

Event duration

 10 µs - 99.999 s

Event counter

 1 - 99,999, selectable

 OUTPUTS

 

EUT terminals

 L, N and PE

CRO trigger

 5 V trigger signal for oscilloscope

MEASUREMENTS

 

EUT voltage (rms)

 In the touch screen

EUT current (rms)

 In the touch screen

MON V

 Measurement of the EUT voltage, built-in divider: 300 V: 42,5:1, 10 V =425 Vpk, 400 V: 56.6:1, 10 V =566 Vpk

MON I

 Measurement of the EUT current, 16 A: 7 A/V; 10 V =70 Apk, 32 A: 10 A/V; 10 V =100 Apk

 TEST ROUTINES

 

Quick Start

 On-line adjustable parameters, easy-to-use

Standard Test routines

 As per IEC/EN 61000-4-11 for AC supplies As per IEC/EN 61000-4-29 for DC supplies As per EN 61000-6-1, -6-2 Manual Standard Test routine

Extended Test routines

 Voltage variation, control of an external variac, Phase angle iteration, Reduced time iteration, Angle inverse mode, Random by step and list Inverse mode

50/60 Hz magnetic field

 As per IEC/EN 61000-4-8 Test levels 1, 3, 10 and 30 A/m with external current transformer MC 2630, Test levels 100, 300 and 1,000 A/m with external current transformer MC 26100

 OPTIONS

 

TVT 1-250-16

 Tapped autotransformer as per IEC/EN 61000-4-11 Ed 2.0

TVT 1-250-16

 Tapped autotransformer as per IEC/EN 61000-4-11 Ed 2.0 with automatic change of tap

variac NX 1-260-16

 Motorized variac (0 - 260 V, 16 A)

variac NX 1-260-32

 Motorized variac (0 - 260 V, 32 A)

MFC 1000

 Magnetic field coil, 1 m x 1 m, up to >1000 A/m (with trolley)

MFC 1000.1

 Magnetic field coil, 1 m x 1 m, up to >1000 A/m (with stand)

MFT 30

 Current transformer for magnetic fields up to 30 A/m

MFT 100

 Current transformer for magnetic fields up to 1,000 A/m

SVP 1700

 Calibration box for inrush current verification as per IEC/EN 61000-4-11

SVP 100

 100 ohm low inductive load resistor, for rise and fall time verification

 RINGWAVE MODULE

 

Test voltage

 200 V - 7,000 V ± 10%

Voltage

 Wave shape (open circuit)

Rise time

 0.5 µs ± 30% (first peak)

Oscillation frequency

 100 kHz ± 10%

Decaying

 Peak 2 to peak 1 = 40 - 110% Peak 3 to peak 2 = 40 - 80% Peak 4 to peak 3 = 40 - 80%

Current

 Wave shape (short circuit)

Rise time

 0.2 µs < tr <= 1.0 µs

Oscillation frequency

 100 kHz ± 10%

Source impedance

 12 ohm, 30 ohm, 50 ohm

Peak current

 As per selected source impedance

Polarity

 Positive, negative, alternate

 TRIGGER CIRCUIT

 

Release of pulses

 Automatic, manual, external

Synchronization

 0° - 360°, resolution 1°

Repetition rate

 max. 1 Hz (1 s - 9999 s)

Event counter

 1 - 99,999, selectable

 OUTPUTS

 

Direct

 Via HV-safety lab connectors

Coupling mode

 L, N, PE; line to line and line(s) to ground

DUT supply

 AC: 300 V / 400 V, 50/60 Hz DC: 300 V / 400 V, Current: 16 A / 32 A

CRO trigger

 5 V trigger signal for oscilloscope

 MEASUREMENTS

 

CRO Û-monitor

 10 Vp at 7,000 V

CRO Î-monitor

 10 Vp at 3,500 A

Peak voltage

 500 V - 7000 V in the touch display

 OPTIONS

 

DCD 7 sr-4-x

 Coupling network for 4 signal/data lines as per IEC/EN 61000-4-12 Ed 3.0

DCD 7 sr-8-x

 Coupling network for 4 signal/data lines as per IEC/EN 61000-4-12 Ed 3.0

HSC 4-8

 Coupling/decoupling network for testing unshielded and shielded high-speed communication lines (Ethernet lines)

SPN 508N1

 Ringwave protection network to reduce the surge voltage <10 V at the AE

 TSURGE MODULE, (OPTIONAL)

 

Test voltage (o.c.)

 200 V - 7,000 V ± 10%

Energy storage capacitor

 20 µF

Polarity

 Positive, negative, alternating

 

 As per ITU and ETSI recommendations

Front time

 10 µs ± 30%

Pulse duration

 700 µs ± 20%

 

 As per FCC part 68, Pulse B

Front time

 9 µs ± 30%

Pulse duration

 720 µs ± 20%

Output current @25 ohm output

 5 A - 175 A (short circuit)

Rise time

 5 µs ± 30%

Pulse duration

 320 µs ± 20%

 

 As per IEC 61000-4-5

Rise time

 10 µs ± 30%

Pulse duration

 700 µs ± 20%

Output current @25 ohm output

 5 A - 175 A (short circuit)

Rise time

 5 µs ± 20%

Pulse duration

 320 µs ± 20%

 TRIGGER CIRCUIT

 

Trigger of events

 Automatic, manual, external

Repetition rate

 max. 0.33 Hz (3 s - 999 s)

Event counter

 1 - 99,999, selectable

 OUTPUTS

 

As per ITU

 For 2-wire T1/T2 with 25 ohm each

As per FCC part 68

 For 2-wire T1/T2 with 25 ohm each

As per IEC 61000-4-5 Ed 3.0

 For 4-wire T1/T2/T3/T4 with 25 ohm each

 

 For other requirements special output configurations are available

 OPTIONS

 

DCD 7 st-4-1

 Coupling/decoupling network for unshielded symmetrical lines (communication lines) as per IEC/EN 61000-4-5 Ed.3 (fig. 10) for 4 lines

DCD 7 st-8-1

 Coupling/decoupling network for unshielded symmetrical lines (communication lines) as per IEC/EN 61000-4-5 Ed.3 (fig. 10) for 8 lines.

 INTERFACES

 

Serial interface

 2 x USB A for memory stick, 1 x USB B for service only, Opto - Link to USB for remote

Lan

 Ethernet for remote

Analog output

 0 - 10 VDC to control an external transformer

Sys.link

 26 pin high density connector to control an external coupling network

Fail inputs

 EUT monitoring via input (one each) EUT Monitor 1 EUT Monitor 2

Ext. Trigger

 BNC Ext. Trigger IN pos slope 5 V

Ext. Sync Input

 Differential input, 50 V - 690 VAC, 2 x 4 mm MC Safety connectors

 DIMENSIONS AND WEIGHT

 

16 A models

 19"/6 HU, 500 mm deep, 19"/9 HU, with telecom module, approx. 30 kg

32 A models

 19"/6 HU, 500 mm deep, 19"/9 HU, with telecom module, approx. 40 kg

 ENVIRONMENT

 

Temperature

 10 °C to 35 °C (Operation) -10 °C to 60 °C (Storage)

Humidity

 30 % to 70 %, non condensing

Atmospheric pressure

 86 kPa (860 mbar) to 106 kPa (1,060 mbar)

 MAINS

 

Supply voltage

 85 V - 264 V

Frequency

 50/60 Hz

Power

 approx. 75 W

Fuses

 115 V: 2 x 4 A slow blow, 230 V: 2 x 2 A slow blow

 SAFETY

 

Safety standard

 IEC/EN 61010

Security circuit

 Control input (24 VDC)

Warning lamp

 Floating contact (max. 60 V/2 A)

 

Packing List/Accessories

Included with Rental Of EM Test NX7

Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. 

 

NX7

    • Conducted Immunity System
    • Laptop
    • Power Cord
    • Printed Manual 
    • Calibration Documentation
    • ESC EUT Power In Cord
    • ESA 1.6 EUT Supply Adapter
    • SCC AD Short Circuit Interlock
    • SWLAD Warning Lamp Adapter Interlock
    • Ethernet Cable
    • Software on USB Stick
    • Software License
    • UOC Optical Converter USB to LWL
    • 5m. Orange Fiber-optic cable
    • EFT Ground Strip
    • Case

     

    Standards

    Widely Used Standards

     

    This list is a more comprehensive list of all the standards covered with this conducted immunity generator. For assured compliance to a particular standard, confirm prior to rental. This EM Test equipment has the ability to either cover all, or part of the standards below.

     

    • ANSI/IEEE C37.90
    • ANSI/IEEE C62.41
    • ECE-R10
    • EN 300329
    • EN 300340
    • EN 300342-1
    • EN 300386 V1.3.2
    • EN 301489-1
    • EN 301489-17
    • EN 301489-24
    • EN 301489-7
    • EN 50121
    • EN 50121-3-2
    • EN 50121-4
    • EN 50121-5
    • EN 55024
    • EN 61000-4-11
    • EN 61000-4-29
    • EN 61000-4-4
    • EN 61000-4-5
    • EN 61000-4-8
    • EN 61000-4-9
    • EN 61000-6-1
    • EN 61000-6-2
    • FCC 97-270 (part 68)
    • IEC 60255-22-5
    • IEC 61000-4-11
    • IEC 61000-4-12
    • IEC 61000-4-29
    • IEC 61000-4-4
    • IEC 61000-4-5
    • IEC 61000-4-8
    • IEC 61000-4-9
    • IEC 61326
    • IEC 61850-3
    • ITU-T K.20
    • ITU-T K.21
    • ITU-T K.41
    • ITU-T K.45
      All Accessories

      Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

      Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

       

      NX7 Full Accessory List
      Item Capabilities
      Variac NX 1-260-16 A motorized variac is offered as an alternative to the tapped autotransformers for voltage dips/interruptions and voltage variation tests as per IEC/EN 61000-4-11. The motorized variac can also be used for automated magnetic field tests.
      V 4780 

      The V 4780 tapped autotransformer is designed to supply the required voltages as per IEC/EN 61000-4-11 to perform voltage dips.

      V 4780S2

      The V 4780S2 is an automatic tapped auto transformer, designed to supply the required voltages as per IEC/EN 61000-4-11 to perform voltage dips and interruptions. Compared to the manually operated V 4780, the V 4780S2 model offers automatic change of taps according to the selected voltage level.

      DCD 5 SR- and ST-Series DCD 5 sr- and st-series coupling/decoupling networks are available to perform surge tests on I/O lines, signal/data lines and telecom lines as per
      IEC/EN 61000-4-5 Ed 3.0

      The DCD 5 sr- series couples surge and ring wave
      impulses to unsymmetrical signal and datalines
      for 4 or 8 lines.

      The DCD 5 st- series couples surge and telecomsurge
      impulses to symmetrical signal and datalines for 2 or 4
      pairs of signal lines.
      MFC 1000

      The MFC 1000 is a 1m x 1m magnetic field coil as specified in IEC/EN 61000-4-8 and IEC/EN 61000-4-9. Its design allows easy moving of the coil. The field coil is adjustable in height and allows for 360 degree rotation.
      To generate power-frequency magnetic fields in the lower range the current transformer MFT 30 is used while high-field strength above 100 A/m up to 1000 A/m requires the MFT 100 current transformer.

      CCI 

      Capacitive coupling clamp as per specification IEC/EN 61000-4-4.

      ITP 

      ITP is a tool being used for development test. It consists of a variety of electrical field probes. The probes allow to locate weak points within a system or on a PCB. The burst pulse is used to generate the disturbance signal.

      PVF BKIT 1

      As per IEC/EN 61000-4-4 the characteristic of the burst generator needs to be verified with two different loads, 50 ohm and 1,000 ohm. EM TEST offers a calibration kit consisting of the two loads and an adapter to verify the pulses at the EUT output.

      CCI PVKIT 1

      The IEC/EN 61000-4-4 Ed 3.0 standard published in 2012 recommends the calibration of the capacitive coupling clamp into a 50 ohm coaxial load.
      The capacitive coupling clamp (CCI or HFK) is connected to the 50 ohm output of the EFT generator. A flexible insulated plate inside the capacitive coupling clamp is connected to a coaxial 50 ohm load resistor for verifying the EFT/Burst wave of the capacitive coupling clamp.

      CA PFS

      The inrush current capability of PowerFail generators as per EN/IEC 61000-4-11 and IEC/EN 61000-4-34 can be verified by means of the CA PFS circuit box. The circuit is specified in Annexes of EN/IEC 61000-4-11, -34 Standard. The inrush current is measured by means of the built-in current delivering a voltage signal of 10 mV/A at the corresponding BNC output connected to an oscilloscope with selected 1 MOhm input impedance.

      HSC 4-8 

      The HSC 4-8 from AMETEK CTS is the first coupling/decoupling network available on the market to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000MBit/s.
      Additionally, the HSC 4-8 can be used as a coupling/decoupling network to apply Burst- as well as Ringwave pulses to unshielded symmetrical interconnection lines. The HSC 4-8 meets the requirements according Figure 11 and Figure 12 to the standards IEC 61000-4-5 (Ed. 3.0 :2014) and IEC 61000-4-12 (Ed. 3.0 :2017) Figure 10.

      NX7 Series

        

       ACCESSORIES INCLUDED

       

      Mains supply

       Plug depends on the country of use

      EUT supply

       Plug depends on the country of use

      EUT adapter

       Socket depends on the country of use

       

       Operation manual, Calibration certificate, iec.control remote control software

       OPTIONS

       

      coupling NX7

       3-phase coupling/decoupling networks as per - IEC/EN 61000-4-4 and - IEC/EN 61000-4-5 up to 200 A per phase

      iec.control

       Remote control and documentation software, including standard test routines and reporting capabilities. included: UOC USB-Optolink Converter

      UOC

       USB-Optolink Converter, Optical Fibre cable, 5 m

       AVAILABLE MODELS: 300 V

       

      Compact NX7 series

       Compact simulator with

      compact NX7 bsp-1-300-16

       Burst, Surge, Power Fail, 300 V, 16 A

      compact NX7 bspr-1-300-16

       Burst, Surge, Power Fail, Ringwave 300 V, 16 A

      compact NX7 bspt-1-300-16

       Burst, Surge, Power Fail, Telecom Surge 300 V, 16 A

      compact NX7 bsprt-1-300-16

       Burst, Surge, Power Fail, Ringwave, Telecom Surge 300 V, 16 A

      compact NX7 bs-1-300-16

       Burst, Surge 300 V, 16 A

      compact NX7 bst 1-300-16

       Burst, Surge, Telecom Surge 300 V, 16 A

      compact NX7 sp-1-300-16

       Surge, Power Fail, 300 V, 16 A

      compact NX7 st-1-300-16

       Surge, Telecom Surge 300 V, 16 A

       AVAILABLE MODELS: 400 V

       

      compact NX7 bsp-1-400-32

       Burst, Surge, Power Fail, 400 V, 32 A

      compact NX7 bspr-1-400-32

       Burst, Surge, Power Fail, Ringwave, 400 V, 32 A

      compact NX7 bspt-1-400-32

       Burst, Surge, Power Fail, Telecom Surge, 400 V, 32 A

      compact NX7 bsprt-1-400-32

       Burst, Surge, Power Fail, Ringwave, Telecom Surge, 400 V, 32 A

       AVAILABLE MODELS: WITHOUT COUPLER, 400 V (P-N), 3 X 690 V (P-P)

       

       

       These models requires an external coupler 3 x 690 V

      compact NX7 bs-0-690

       Burst, Surge

      compact NX7 bsr-0-690

       Burst, Surge, Ring wave