Ask Us About: EMC-CS-2009.1 Rentals - Automotive EMC Test Equipment
Transient Specialists
Filters
Recent Views
EMC-CS-2009.1 Rentals - Automotive EMC Test Equipment
Showing 17 - 32 of 37 products
Display
View
EM Test AN 200N100 - Rent 100 Amp 5uH DC LISN
- Max 1000 Volts 100 Amps DC (150 Amp Peak)
- ISO 7637-2, ISO 11452-4, & CISPR 25 Compliant
- Switch for Selecting Testing Requirements
Teseq ISO 7637-3 ICC Test System - Rental Transient Injection Kit
- Teseq ISO 7637-3 ICC for NSG 5500 System
- Used for Injection of Pulse 2A
- Includes CIP 9136A, PCJ 9201, & INA 5580
EM Test AMP 200N2 - Rent LF Signal & Amplifier DC - 500 KHz
- Output Max. 160 V p-p, 50 V rms
- Output Current Max. 18 A rms
- Automatic Closed Loop Test Procedures
Conducted Transient Emissions Set ISO 7637-2 EM Test
- Electronic Switch, Artificial Network, & RS-Box
- BS 200N100 Electronic switch, 60V DC/100A
- AN 200N100 1,000V DC, 250V AC (up to 1kHz)
EM Test CN 200N100 - Rent 100 Amp Audio Transformer
- Frequency response 10 Hz to 500 kHz
- Audio power up to 3 x 200 W
- Turns ratio 2:1 step down
Teseq HV-AN 150 - Rent 5uH 150 Amp Artificial Network
- Max 1000 V/150 A DC or 500 V/150 A AC
- HV Compliant to ISO 7637-4 & CISPR 25
- Jumpers Provide LISN Path Configuration
Schwarzbeck NNHV 8123-200 - Rent 5uH 200 Amp DC LISN
- Max 1000 V/200 A DC or 700 V/200 A AC
- Includes HVSE 8600 Shielded Enclosure
- 5uH LISN in Accordance with CISPR 25
Teseq SME HV-AN 150 - AN Shielded Metal Enclosure
- Designed for use with Teseq HV-AN 150s
- Rugged Design using Stainless Steel
- Compliant to HV CISPR 12/25 & ISO 7637-4
Schwarzbeck HVSE 8600 - Automotive Shielded Enclosure
- Designed for use with NNHV 8123-200
- Compliant to HV CISPR 25 & BMW GS 95025-1
- Rented with set of NNHV 8123-200 LISNs
EM Test BS 200N100 - Electronic Switch for Voltage Transient Testing
- Electronic Switch Accordance with ISO 7637 Part 2
- Rented with EM Test Transient Emissions Set
- Max 60 Volts & 100 Amps Cont. (400A @ 200ms)
Teseq INA 5540-GA - GMW 3172 Section 9.2.5 Adapter
- Adapter for Pulse Superimposed Voltage Tests
- Two +ARB Options Required in NSG 5500
- Designed for GMW 3172 Section 9.2.5
Schwarzbeck NNLK 8129 - Rent 50uH 200 Amp LISN
- Impedance 50 µH || 50 Ω
- Frequency Range 150 kHz – 30 MHz
- Maximum: 200 Amps 700 Volts AC
EM Test AutoWave-WR - Rent 4-Channel Generator & Recorder
- 4-channel Arbitrary Waveform Generator
- 2-channel Transient Waveform Recorder
- Simultaneous Recording/Generation
EM Test VDS 200Q10 - Rent 10 Amp Battery Simulator
- -60 to +60 Volts 10 Amps Continuous
- Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
- Four Quadrant, Bipolar Amplifier
EM Test VDS 200Q100.2 - Rent 100 Amp Battery Simulator/Source
- -60 to +60 Volts 100 Amps Continuous
- Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
- Extended Range 80 Volts 80 Amps
EM Test CA LV 148 - Rent LV 148 Verification Kit for PFM 200N100
- 10 Ohm & 100 Ohm Power Calibration Loads
- Designed for up to 48 Volt Battery Lines
- Low Inductive, High Precision Load Resistor
37 products
Overview
Rentals of automotive EMC test equipment for FMC1278 provide the necessary equipment for testing with technical support, at a fraction of the price of purchasing. This standard is the Ford's EMC testing requirements for the EMC of vehicle electronic or electrical systems to assure compliance with present and anticipated future regulation. It replaces EMC-CS-2009 standard for Ford Motor Company requirements and includes components of CISPR 25, ISO 11452-2, ISO 7637 for testing. This automotive standard applies to all 12 and 24 volt DC electronic or electrical systems both components and subsystems. This automotive standard, as well as other Ford standards, can be download via the Ford EMC website. FMC1278 differentiates testing based upon functional importance classification and functional performance status. It requires ESD, load dump, fast transients, and dips testing.
Testing
Testing according to this Ford automotive EMC standard places requirements on the sequence of how testing is to be completed. The first testing to be completed is ESD testing. It is encouraged that RF Emissions and RF Immunity be conducted next following that. Should ESD testing (section 25) not be conducted first, will result in non-acceptance of the test results. The electrostatic discharge component of testing requires 150pF/2kΩ for unpowered testing and 330pF/2kΩ powered testing and done in compliance with ISO 10605. The voltage level for testing begins at 4kV and goes as high as 25kV. FMC1278 also includes ISO 7637 pulses 1,2,3 and 5 with modifications. Additional information on these pulses is available sections 18 and 19 of this standard.
Equipment
To facilitate testing we provide FMC1278 rental equipment and offer products from both Teseq and EM Test. The Teseq NSG 5500 Rental with the PA5840 by Teseq provides testing to many of the automotive waveforms required by this standard and ISO 7637. The NSG 5500 is the control unit and the PA5840 is a programmable battery available in both 25 and 100Amp models. The EM Test solution, the LD200N, VDS200N, and UCS200N allows for testing for an individual sections and waveforms. This is a cost-effective solution for specific waveform testing requirements. Ford EMC testing requirements also have an ESD component which we have both the NSG 437 and ESD3000 as solutions providing required networks and 30kV capabilities. All of our automotive EMC test equipment rentals come with an A2LA accredited calibration and free technical support. Both the Teseq and EM Test immunity generators provide unique software and can be controlled via laptop computer.
Filters (0)
Transient Specialists
Filters