Military and Avionics Standards

Showing 1 to 9 of 16 products

RENTAL

AVI3000 - Avionics EMC Immunity Test System

All in One solution to indirect lightning testing needs. AVI3000 is a system that fully integrates DO-160 Section 22 & MIL-STD-461G CS117 Lightning Immunity Test System with BCI coupler.

RENTAL

A Solar 9355 - Pulse Generator Per Mil Std 461 CS115

Solar Electronics 9355 pulse generator (2x35 nanoseconds) for Mil Std 461,  CS 115  is designed to provide impulse excitation by means of an injection probe placed around interconnecting cables or power wires. The charged line potential for the Solar9355 is adjustable from less than 10 V to approximately 1900 V. Includes adjustable pulse rate from less than 1.0 pulse per second to 120 pulse per second, and manual triggering via front panel push button.

 

RENTAL

Solar 8282 - Conducted Transient Susceptibility Generator Per Mil Std 461 CS06

The Solar8282 Electronics pulse generator for conducted transient susceptibility testing for method CS06 of Mil Std 461(NEMA TS2) provides all the waveshapes required by MIL-STD-461 and many other military EMI specifications. All functions are selected by push buttons which are lighted when activated.

Three different spike durations are provided: 0.15 µS, 5.0 µS, and 10.0 µS.Two sets of output terminals allow either parallel or series injection into the power line. Series injection is used on AC lines. Parallel injection is used on DC lines. The output winding used for series injection can carry 25 A of power current. The output terminals are isolated from the chassis and the power cord.

 

RENTAL

Solar 7054 - Spike Generator for DO 160 sec 17, Mil Std 461 CS06

The Solar7054 600V spike generator allows testing for method CS06 of MIL-STD-461 and Section 17 testing of RTCA DO-160 as well various missile specifications and other requirements. The transient shape approximates the curve given in Figure 19 of MIL-STD-462 with less than or equal to 2.0 µS rise time and approximately 10 µS fall time.

On 50, 60 or 400 Hz power lines the transient can be applied in a periodic manner to the negative or the positive half-cycle of the power frequency.Two sets of output terminals allow either parallel or series injection into the power line. The output winding used for series injection can carry 25 A of power current. The output terminals are isolated from the chassis and the power cord.

RENTAL

Solar 7032 - Power Line Transformer

The Solar7032 is an electronics power line isolation transformer for MIL-STD 461 CS06 and MIL-STD 1399. This transformer is equipped with a male connector on the 115 V winding and a female connector on the 230 V winding. The connectors are the international style IEC-320/CEE 22. Mating plugs not supplied. Rated at 800 W, 50-60 Hz.

RENTAL

Solar 6512 - 10 Microfarad Feed Thru Cap

The Solar6512 Electronics 10µF Feed-Thru Capacitor, part # 6512-106Rfor Mil Std 461 sec 18, Mil Std 461 sec 20, Mil Std 461 sec 21, is rented in sets of 2.Three different spike durations are provided: 0.15 µS, 5.0 µS, and 10.0 µS. The amplitude of the spike voltage is fully adjustable and is displayed on a digital meter.

The Solar Electronics 6512 provides up to 600 V peak amplitude for each of the 0.15, 5.0 and 10.0 µS spikes. The output voltage rises steeply to peak amplitude as adjusted by the panel control, then falls exponentially to cross through zero at the duration of 0.15, 5.0, or 10.0 µS as selected by push buttons. The voltage falls below zero and "rings" for a period determined by the inductance in the output circuit or the load.

RENTAL

Solar 6220-4 / 6220-1B - HV Audio Isolation Transformer

The Solar6220-4 / Solar6220-1B electronics audio isolation transformer allows testing for DO-160 Sec 18,sec 20. The transformer is capable of handing up to 200 W of audio power into its primary over the frequency range 30 Hz to 250 kHz. The turns ratio provides a two-to-one step down to the special secondary winding. The secondary will handle up to 50 A of AC or DC without saturating the transformer.

Another secondary winding is connected to a pair of binding posts suitable for connecting to AC voltmeter as directed by the applicable EMI specifications.The transformer may be used as a 4 Ω primary and 1 Ω secondary or 2.4 Ω primary and 0.6 Ω secondary or 2 Ω primary and 0.5 Ω secondary.

RENTAL

Solar 2854 - Spike Generator for Mil Std 461 CS106

The Solar2854 Spike generator for conducted transient susceptibility tests per MIL STD 461, CS106 provides 5 μS ±22% pulse with a 1.5 μS ± 0.5 μS rise time across a 5.0 Ω non-inductive resistor.Voltage is adjustable to greater than 400 V. The undershoot is limited to less than 120 V peak (maximum) and less than 20 μ

Two sets of output terminals allow either parallel or series injection into the power line. The series injection may be used on DC and AC lines. Parallel injection should be used on DC lines only. The output winding used for series injection can carry 25 A of power current.

RENTAL

Solar 2201 - Impedance Matching Transformer

Solar Electronics Impedance Matching Transformer for DO-160 Section 17 (for use with the Solar 7054-1)

Showing 1 to 9 of 16 products