Data Sheet User ManualDescription
The compact Next Generation NX5 is the most versatile tester to address transient and power fail requirements for both international and commercial standards.
Featuring an easy-to-use color touch screen, the NX5 provides an economical solution for pre-compliance immunity testing as well as full-compliance testing and CE Marking. Its internal single-phase Coupling/Decoupling Network (CDN) can be extended for testing three-phase EUTs by means of an automatically controlled external CDN up to 200 A per phase. EM TEST supplies a large range of accessories for various applications such as magnetic field tests and more.
Specifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11 (with optional V4780S2) CE Mark |
Integrated CDN: |
|
AC Voltage and Current |
400V/16A; 50/60Hz |
DC Voltage and Current |
400V/16A |
EFT Burst 5/50ns: |
|
Standards |
EN/IEC 61000-4-4, and EN 61000-6-1,-6-2, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50µs pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50µs pulse width -15ns/+100ns |
Voltage Amplitude |
200-5,500V ±10%, 100V-2,750V ±10% into 50Ω |
Burst Duration |
td = 0.10ms - 999ms |
Burst Period |
tr = 10ms - 9,999ms |
Frequency |
f = 0.1kHz - 1,000kHz |
Combination Wave Surge: |
|
Standards |
EN/IEC 61000-4-5 , EN 61000-6-1, -6-2, CEMark |
Open Circuit Voltage Waveform |
160V – 5,000V, Front Time1.2us ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
2,500A ±10%, 8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
160V–5kV ±10% |
Peak Short Circuit Current |
125A–3kA ±10%@2 Ω, 20.8-500A ±10%@12Ω |
Pulse Repetition Rate |
MAX. 1Hz (1s – 999s) |
Peak Voltage and Current Monitoring |
5,000V, 2,500A in the LCD Display |
Monitoring of EUT voltage and current |
Built-in 100:1 voltage measurement 10mV/A, max. 1,000A |
Weight |
35 kg, 77 pounds |
Dimensions |
50x43x28 cm, 20x17x11 inches |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this conducted immunity generator. For assured compliance to a particular standard, confirm prior to rental. This EM Test equipment has the ability to either cover all, or part of the standards below.
- ECE-R10
- EN 300329
- EN 300340
- EN 300342-1
- EN 300386 V1.3.2
- EN 301489-1
- EN 301489-17
- EN 301489-24
- EN 301489-7
- EN 50121
- EN 55024
- EN 61000-4-11
- EN 61000-4-29
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-8
- EN 61000-4-9
- EN 61000-6-1
- EN 61000-6-2
- FCC 97-270 (part 68)
- IEC 60255-22-5
- IEC 61000-4-11
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- IEC 61326
- IEC 61850-3
- ITU-T K.20
- ITU-T K.21
- ITU-T K.41
- ITU-T K.45
Configurations
Configurations EM Test NX5 Series
There are a variety of different configurations of the NX 5 series of test equipment. These vary depending upon the waveform generator/testing capabilities and capabilities of built-in coupler. Testing capabilities include Burst/EFT (electrical fast transients), Surge (combination wave), Power Fall, and Telecom Surge in with both 16 amp and 32 amp CDNs.