Haefely FP-COMB 32

Rent 3-Phase 480 Volt 32 Amp CDN
  • Coupler for Surge, EFT, & Ringwave Pulses
  • Maximum 480 Volts 32 Amps AC/DC
  • Automatic Coupler for Axos5/8 Systems
  • Compliant to ANSI C62.41 Requirements
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • FP-COMB 32#
  • AC Mains Cable
  • EUT mains cable 32Amps
  • EUT mains adapter 32Amps
  • Calibration Certificate
  • Surge Cable to Axos (5 & 8)
  • EFT/Burst Cable to Axos (5 & 8)
  • Shipping Case
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The FP-COMB 32 coupling/decoupling network – for Surge Combination Wave, Ring Wave and EFT/Burst – is fully compliant with the standard requirements of IEC/EN 61000-4-4, IEC/EN 61000-4-5 and IEC/EN 61000-4-12.

The FP-COMB 32 is controlled by the AXOS5 / AXOS8 expandable immunity test system(s). The CDN automatically changes the coupling paths, phase angles and source impedance based on test parameters set by the user via the AXOS controller – depending on the standard and coupling mode.

The FP-COMB 32 was designed to reduce residual voltage levels at the EUT mains input by integrating the proper decoupling inductors for each type of CDN application in order to meet the requirements (with regard to voltage drop at the rated current). Apart from covering the EN/IEC 61000-4-5 standard, the FPCOMB 32 also covers tests to meet surge requirements outlined in ANSI/IEEE C62.41.

Specifications
Coupling:
CDN Inputs
Banana socket front panel 5 connectors
CDN Outputs
Banana socket front panel 5 connectors
Waveforms
EFT / Burst, Surge Combination Wave, Ring Wave
Maximum EFT / Burst Input Voltage
5 kV
Maximum Surge Combination Wave Input Voltage
7 kV
Maximum Ringwave Input Voltage
7 kV
Coupling Path Selection
Automatic IEC + ANSI
Synchronization
10 V to 480 V input voltage, 0 to 359 degrees, step 1 degree
Sync. On coupling path, output BNC rear panel
Decoupling:
Voltage AC
Up to 480 V AC 16.7 Hz, 50 Hz, 60 Hz
Voltage DC
Up to 480 V DC
Nominal Current
32 A
EFT / Burst Input Voltage Range
0.2 kV to 5 kV
Surge Combination Wave Input Voltage Range
0.2 kV to 7 kV
Ring Wave Input Voltage Range
0.2 kV to 7 kV
Coupling Path Selection
Automatic
Synchronization
10 V to 480 V input voltage, 0 to 359 degrees, step 1 degree
Interface:
Extension Connector (37 pol. Sub-D connector)
Warning on AXOS Display
LEDs
Indication of coupling path Power ON LED CDN active LED
Video Guides
AXOS & FP-COMB2 System Setup & Testing
Related Videos
Haefely AXOS Generator Overview
Haefely AXOS5 System Overview & Surge Testing
Haefely AXOS 5 Setup & EFT Testing (with IP4B)
AXOS Remote Software Setup Guide