California Instruments 5001 i/iX - Rent 5kVA AC Source

California Instruments 5kVA AC/DC Source:

  • Single Phase High Effeciency AC/DC Supply 
  • AC Voltage 300V & DC Voltage 400V
  • Frequency Range 16Hz - 1kHz
  • Low Harmonics Distortion & Noise
  • AC Dips Swtich EOS1 Available  

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Programmable Power Sources

Overview

The iX Series II represents a new generation of AC and DC power source that addresses increasing demands on test equipment to perform more functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the iX Series II systems are capable of handling complex applications that have traditionally required multiple instruments.

The sleek integrated approach of the iX Series II avoids the cable clutter that is commonly found in AC test systems. The i/iX Series II is rackmountable with a 4U chassis design. All connections are made internally and the need for external digital multimeters, power harmonics analyzer and current shunts or clamps is completely eliminated.

Using a state of the art digital signal processor in conjunction with precision high resolution A/D converters, the iX Series II provides more accuracy and resolution than can be found in some dedicated harmonic power analyzers. Since many components in the iX Series II are shared between the AC/DC source and the power analyzer, the total cost of the integrated system is less than the typical cost of a multiple unit system.

For less demanding applications, the i Series II provides similar output and transient capabilities as the iX Series II, as well as basic measurements.

Data Sheet User Manual

Specifications

Total Power 

5000 VA

Frequency 

 Range: 16.00-1000 Hz

Load Power Factor

0 to unity at full output VA

 Voltage Ranges (AC) 

V Low - 0-150V

V High 0-300V

Output Noise (20 kHz to 1 MHz

< 250 mVrms typ., < 500 mVrms max

Harmonic Distortion (Linear)

< 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)

 

You may also like