Description
Overview
The EOS 1 by California Instruments is an electronic output switch provides full AC source compliance for dips and Interrupts testings. There are many ways to test a product to verify immunity from line variations, and some form of standardization, for comparison purposes, is desirable.The standard, EN/IEC 61000-4-11, seeks to specify the parametric requirements of an AC source suitable for performing the specified tests. Generally, these requirements go beyond what is necessary on a particular product.
Data SheetSpecifications
Common Standards |
EN/IEC 61000-4-11 |
Input |
|
Line Voltage |
115 Vac ±10% /230 Vac ±10% |
Line Current |
<0.4 A@115Vac/60Hz <0.2 A@230Vac/50Hz |
Line Frequency |
47-63Hz |
Fuse Rating |
.5A slow acting@ 115Vac .25A slow acting @230 Vac |
Output
|
|
IEC-4-11 Test Mode Engaged |
|
Voltage |
|
Range |
100-270 Vrms |
Regulation |
<5%, 100% output <7%, 80% output <7%, 70% output <10%, 40% output |
Over/Undershoot |
<5% into a 100 Ohm resistive load |
Rise/Fall Times |
Between 1µsec & 5µsec at 10% and 90% into a 100 Ohm resistive load |
Programmable Output Levels |
100%,70%,40% and 0% of U nom |
Frequency |
|
Range |
50 Hz/60 Hz |
Accuracy |
±0.02% |
Phase |
|
Range |
0.0 – 360.0° |
Accuracy |
±1.0° |
Maximum RMS Currrent |
|
At 100% U nom |
18.5 A rms |
At 80% U nom |
26.4 A rms |
At 70% U nom |
23.1 A rms |
At 40% U nom |
46.2 A rms |
At 0% U nom |
n/a |
Bypass Mode: |
|
Maximum RMS Current |
37 A rms |
Mechanical |
|
Dimensions |
178 x 483 x 610 mm, 7” x 19” X 24” |
Weight |
32kg, 70lbs |