Ask Us About: SAE J1455 Rentals - Automotive Transients & Radiated Immunity Equipment
Transient Specialists
Filters
Recent Views
SAE J1455 Rentals - Automotive Transients & Radiated Immunity Equipment


- LF Conducted Immunity Transformer 100 Amps
- Frequency Response 10 Hz to 500 kHz
- Ideal for ISO 7637-4 Tests With AMP200N2


- 150Amp 5µH 1kV DC AMN/LISN
- CISPR 25 & ISO/DTS 7637-4 HV Compliant
- EXT 10uF Capacitor for RTCA/DO-160


- 5µH ANs/LISNs 200Amps/1kV DC
- HV Compliant to CISPR 25 & ISO/DTS 7637-4
- Includes HVSE 8600 Shielded Housing


- Rented with Pair of Teseq HV-AN 150
- Compliant to HV CISPR 12/25 & ISO 7637-4
- Includes EXT 10uF Capacitor for MIL-STD


- Rented with set of NNHV 8123-200 ANs/LISNs
- Compliant to HV CISPR 25 & BMW GS 95025-1
- Includes BNC Female to Wing Terminal Adapter


- Max Voltage 60V/100Amps Cont.
- Designed for ISO 7637-2 & LV 124
- Rented EM Test Transient Emissions Set


- 200 Amps 400 VAC/800 VDC 50 µH V-LISN
- CISPR 16-1-2 Compliant 150 kHz - 30 MHz
- Used for 3-Phase & HV EUT/DUT


- 100 Amps 250 VAC 50 µH V-LISN
- CISPR 16-1-2 Compliant 9 kHz - 30 MHz
- Used for 3-Phase & HV EUT/DUT


- 4-channel Arbitrary Generator System
- Includes 2-channel recorder (AutoWave-WR)
- Requires DC Programmable Source


- Voltage Drop Simulator - 60 volts/10 amps
- 4 Quadrant DC Voltage Drop Simulator
- Frequency Range DC - 180 kHz


- 80 Volt 100 Amp Battery Simulator
- Ideal for LV124 and LV148 Testing
- Frequency Range DC - 250 kHz


- Load Resistors for 48 Volt Powers Lines
- Software Includes LV 148 Verification
- Optional Item with PFM 200N100 Rental


- Imedance Matching Network for ISO 7637-3
- Deisgned for EM Test Series of Test Generators
- Rented with Teseq CIP 9136A ICC Test Kit
45 products
Description
Overview
General Testing Information
This automotive standard covers a variety of testing for heavy-duty vechiles including the electrical environment (section 4.13). This standard gives recommended practices and EMC testing methods for electrical environments from natural and vehicle-induced sources that influence the performance and reliability of vehicle and tractor/trailer electronic components. It also relates to stationary components which also use the vehicle-based components requirements. This standard is aimed at being used during the design phase so as to develop Immunity system to commonly occurring environmental occurrences. Given the nature of truck and tractor systems three types of transients are tested for load dump, inductive switching, and mutual coupling. This standard often refers to SAE J1113 as a reference for EMI and EMC testing procedures and test levels.
Common Sections & Equipment
Given the overlapping of this manufacturer based standard with the more commonly referenced international International Standards Organization (ISO) standards there is often additional reference materials and solutions available.
- 4.13.2.2.1Conducted Transients (Pulses 1-5)
- 4.13.2.2.2 Coupled Transients - SAE J1113-12
- 4.13.3.4.2 Radiated Electric Field immunity - SAE J1113-21 usually above 100 V/m
- 4.13.2.2.3 Electrostatic Discharge (ESD)
Load Dump - 4.13.2.2.1 a. (Pulse 5)
This pulse, number 5, part of the conducted transients section within the electrical environment section is often referenced by a variety of other international and manufacturer standards. Appendix B within the standard offers additional information on this more commonly occurring event and section 4.13.2.2 "Effects on Performance" also specifically mentions it. Appendix B specifically focuses on considerations with using a clamping device and provides general guidelines should tailor specific waveform medications be required.