Ask Us About: SAE J1455 Rentals - Automotive Transients & Radiated Immunity Equipment
Transient Specialists
Filters
Recent Views
SAE J1455 Rentals - Automotive Transients & Radiated Immunity Equipment
- Designed for use with Teseq HV-AN 150s
- Rugged Design using Stainless Steel
- Compliant to HV CISPR 12/25 & ISO 7637-4
- Designed for use with NNHV 8123-200
- Compliant to HV CISPR 25 & BMW GS 95025-1
- Rented with set of NNHV 8123-200 LISNs
- Electronic Switch Accordance with ISO 7637 Part 2
- Rented with EM Test Transient Emissions Set
- Max 60 Volts & 100 Amps Cont. (400A @ 200ms)
- Impedance 50 µH || 50 Ω
- Frequency Range 150 kHz – 30 MHz
- Maximum: 200 Amps 700 Volts AC
- 4-channel Arbitrary Waveform Generator
- 2-channel Transient Waveform Recorder
- Simultaneous Recording/Generation
- -60 to +60 Volts 10 Amps Continuous
- Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
- Four Quadrant, Bipolar Amplifier
- -60 to +60 Volts 100 Amps Continuous
- Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
- Extended Range 80 Volts 80 Amps
- 10 Ohm & 100 Ohm Power Calibration Loads
- Designed for up to 48 Volt Battery Lines
- Low Inductive, High Precision Load Resistor
- Impedance Network to Achieve Pulse Requirements
- Used with the EM Test UCS 200N Series
- ISO 7637-3 Slow Transient Pulse 2A
- Compliant to FORD EMC-CS-2009
- Used for RI 130 & RI 150 Immunity Tests
- Type N Female Connectors on Fixture
- Compliant for ISO 7637-3 Testing
- Length of Clamp 1000 mm
- 50 Ohm BNC Connectors
- (25 Hz) 9 kHz to 150 kHz Frequency Range
- Compliant to IEC 61000-4-39 & IEC 60601-1-2
- Includes Loop, Sensors, Fixture, and Accessories
- 0.6ohm / 50uH Load as per ISO 7637-2:2004
- Max Supply Voltage 28VDC
- Max Load Current 50A
45 products
Description
Overview
General Testing Information
This automotive standard covers a variety of testing for heavy-duty vechiles including the electrical environment (section 4.13). This standard gives recommended practices and EMC testing methods for electrical environments from natural and vehicle-induced sources that influence the performance and reliability of vehicle and tractor/trailer electronic components. It also relates to stationary components which also use the vehicle-based components requirements. This standard is aimed at being used during the design phase so as to develop Immunity system to commonly occurring environmental occurrences. Given the nature of truck and tractor systems three types of transients are tested for load dump, inductive switching, and mutual coupling. This standard often refers to SAE J1113 as a reference for EMI and EMC testing procedures and test levels.
Common Sections & Equipment
Given the overlapping of this manufacturer based standard with the more commonly referenced international International Standards Organization (ISO) standards there is often additional reference materials and solutions available.
- 4.13.2.2.1Conducted Transients (Pulses 1-5)
- 4.13.2.2.2 Coupled Transients - SAE J1113-12
- 4.13.3.4.2 Radiated Electric Field immunity - SAE J1113-21 usually above 100 V/m
- 4.13.2.2.3 Electrostatic Discharge (ESD)
Load Dump - 4.13.2.2.1 a. (Pulse 5)
This pulse, number 5, part of the conducted transients section within the electrical environment section is often referenced by a variety of other international and manufacturer standards. Appendix B within the standard offers additional information on this more commonly occurring event and section 4.13.2.2 "Effects on Performance" also specifically mentions it. Appendix B specifically focuses on considerations with using a clamping device and provides general guidelines should tailor specific waveform medications be required.